Evaluation of Safety and Efficacy of the EndoLift Liver Retractor
Evaluation of Safety and Efficacy of the EndoLift Liver Retractor: a Pilot Study of a New Internal Laparoscopic Liver Retraction Device
The primary goal of the study is to evaluate the safety of the EndoLift Liver Retractor as an internal laparoscopic liver retraction device. The secondary goals of the study are to evaluate the efficacy of the EndoLift Liver Retractor as an internal laparoscopic liver retraction device and to identify 'best practices' for device utilization.
This study evaluates the use of a specific type of liver retractor (EndoLift). Liver retractors are often necessary during MIS procedures, but this retractor is the only device which is deployed internally (NOT requiring additional skin punctures/incisions for placement of the liver retractor device). All patients undergoing minimally invasive surgery (MIS) at Duke Regional Hospital will be approached.
The new device is expected to have a minimal risk safety profile. The investigators believe that these risks are no more than would be encountered by using any other commercially available retraction device available on the market today. Data will be collected and analyzed by the identified investigators. Continuous variables will be analyzed via T-test and Chi-square analysis will be applied to discontinuous variables. Statistical analysis software such as SPSS® will be utilized when necessary.
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Since the introduction of minimally invasive surgery (MIS) techniques in the 1980's laparoscopic surgery has become the preferred approach for a number of intra-abdominal procedures such as cholecystectomy, gastric bypass, etc.[1] One of the key components of laparoscopic surgery, of any surgery for that matter, is the ability to achieve and maintain adequate visualization of the surgical target throughout the procedure. During certain MIS procedures the patient's internal organs, such as the liver, can block or obscure the surgical view. A number of surgical instruments (retractors) have been developed to help retract abdominal organs "out of the way" during MIS procedures, but all of these devices require an additional abdominal wall puncture/incision to adequately position the device.
Virtual Ports, Ltd. has developed a new laparoscopic liver retractor device, the EndoLift Liver Retractor. This new device does not require additional skin incisions and is placed internally (inside the abdomen) during laparoscopic surgery. The device has 2 ends that "grab" tissue. The body of the device is a smooth, cylindrical steel bar that has minimal risk of traumatizing tissues/organs. The ends of the device are positioned on to peritoneal surfaces (e.g., anterior abdominal wall and/or the right crus of the diaphragm) and the body of the device (smooth cylindrical bar) "pushes" the liver away from the surgical field.
Study Type
Study Type
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
North Carolina
-
Durham, North Carolina, United States, 27710
- Duke Regional Hospital
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
Subjects eligible for this clinical study must fulfill all of the following:
- Subject is 18 years of age or older.
Subject is scheduled for a MIS procedure:
- Laparoscopic Gastric Banding
- Laparoscopic Roux-en-Y Gastric Bypass
- Laparoscopic Sleeve Gastrectomy
- Laparoscopic Fundoplication Procedure (Nissen, Toupet, Dor, etc.)
- Laparoscopic Heller myotomy
- Laparoscopic paraesophageal hernia repair
- Laparoscopic gastric resection
- Subject is able to comprehend and give informed consent for participation in this study.
Exclusion Criteria:
Subjects not eligible for this research study include those that have any of the following:
- Subject is unable to comprehend and give informed consent for participation in this study.
- Subject who are pregnant.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Basic Science
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: EndoLift Liver Retractor
During surgery, the surgeon will use the new internal liver retractor device.
The device will retract the subject's liver out of the way and help the surgeon see better during the surgery.
The device is placed inside the abdomen during the surgery.
It is "clipped" onto 2 safe surfaces inside the abdomen.
The device is removed before the surgery ends.
|
During the surgery, the surgeon will use the new internal liver retractor device.
The device will retract the liver out of the way and help the surgeon see better during the surgery.
The device is placed inside the abdomen during the surgery.
It is "clipped" onto 2 safe surfaces inside the abdomen.
The device is removed before the surgery ends.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Safety
Time Frame: Day 1 post-op
|
The primary study endpoint will be to establish the safety of using the EndoLift Liver Retractor as an internal laparoscopic liver retraction device. Safety will be established by lack of serious events. Events are defined as adverse if they require change in the operative course, a device specific complication and/or association with prolongation of hospital stay. |
Day 1 post-op
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Effective use of the EndoLift Liver Retractor
Time Frame: Up to 6 hours during the operative procedure
|
The effective use of the EndoLift Liver Retractor as a liver retraction device during surgery will be considered a "success". If there is a need to use any additional equipment to retract the liver during the surgery, the subject will be scored a "failure". Study success will be declared if at least 80% of subjects are scored a "success". |
Up to 6 hours during the operative procedure
|
Other Outcome Measures
Other Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Physician satisfaction
Time Frame: Day 1 Post-op
|
Physician satisfaction and surgeon recommendations for 'best practices' during utilization of the EndoLift Liver Retractor will be assessed by questionnaire. Study outcomes will be measured within the hospitalization period. |
Day 1 Post-op
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Investigators
Investigators
- Principal Investigator: Dana Portenier, MD, Duke University
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Estimate)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- Pro00028255
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Laparoscopic Sleeve Gastrectomy
-
NCT05224791RecruitingLaparoscopic Sleeve Gastrectomy | Sleeve Gastrectomy
-
NCT03629808CompletedLaparoscopic Sleeve Gastrectomy
-
NCT03051919CompletedLaparoscopic Sleeve Gastrectomy
-
NCT06970626Recruiting
-
NCT04323696UnknownLaparoscopic Sleeve Gastrectomy
-
NCT06970678Recruiting
-
NCT05485363Not yet recruitingOptic Nerve Sheath Diameter | Laparoscopic Sleeve Gastrectomy
-
NCT03856788CompletedLaparoscopic Sleeve Gastrectomy | Subcostal Transversus Abdominis Plane Block
-
NCT04264364CompletedObesity | Laparoscopic Sleeve Gastrectomy | Endoscopic Sleeve Gastroplasty
-
NCT04452786WithdrawnGlucose Metabolism Disorders | Laparoscopic Sleeve Gastrectomy | Endoscopic Sleeve Gastroplasty | Gut Hormones
Clinical Trials on EndoLift Liver Retractor
-
NCT03795844Completed
-
NCT02926885Completed
-
NCT02685696CompletedSurgical Site Infection
-
NCT07621250CompletedTotal Hip Arthroplasty (THA)
-
NCT01826604Completed
-
NCT07237737Not yet recruitingHip Osteoarthritis | Hip Arthritis
-
NCT01695980CompletedSleep Apnea, Obstructive | Tonsillitis
-
NCT00685932CompletedPregnancy | Complications; Cesarean Section
-
NCT05271734Completed