Evaluation of Safety and Efficacy of the EndoLift Liver Retractor

August 3, 2015 updated by: Duke University

Evaluation of Safety and Efficacy of the EndoLift Liver Retractor: a Pilot Study of a New Internal Laparoscopic Liver Retraction Device

The primary goal of the study is to evaluate the safety of the EndoLift Liver Retractor as an internal laparoscopic liver retraction device. The secondary goals of the study are to evaluate the efficacy of the EndoLift Liver Retractor as an internal laparoscopic liver retraction device and to identify 'best practices' for device utilization.

This study evaluates the use of a specific type of liver retractor (EndoLift). Liver retractors are often necessary during MIS procedures, but this retractor is the only device which is deployed internally (NOT requiring additional skin punctures/incisions for placement of the liver retractor device). All patients undergoing minimally invasive surgery (MIS) at Duke Regional Hospital will be approached.

The new device is expected to have a minimal risk safety profile. The investigators believe that these risks are no more than would be encountered by using any other commercially available retraction device available on the market today. Data will be collected and analyzed by the identified investigators. Continuous variables will be analyzed via T-test and Chi-square analysis will be applied to discontinuous variables. Statistical analysis software such as SPSS® will be utilized when necessary.

Study Overview

Detailed Description

Since the introduction of minimally invasive surgery (MIS) techniques in the 1980's laparoscopic surgery has become the preferred approach for a number of intra-abdominal procedures such as cholecystectomy, gastric bypass, etc.[1] One of the key components of laparoscopic surgery, of any surgery for that matter, is the ability to achieve and maintain adequate visualization of the surgical target throughout the procedure. During certain MIS procedures the patient's internal organs, such as the liver, can block or obscure the surgical view. A number of surgical instruments (retractors) have been developed to help retract abdominal organs "out of the way" during MIS procedures, but all of these devices require an additional abdominal wall puncture/incision to adequately position the device.

Virtual Ports, Ltd. has developed a new laparoscopic liver retractor device, the EndoLift Liver Retractor. This new device does not require additional skin incisions and is placed internally (inside the abdomen) during laparoscopic surgery. The device has 2 ends that "grab" tissue. The body of the device is a smooth, cylindrical steel bar that has minimal risk of traumatizing tissues/organs. The ends of the device are positioned on to peritoneal surfaces (e.g., anterior abdominal wall and/or the right crus of the diaphragm) and the body of the device (smooth cylindrical bar) "pushes" the liver away from the surgical field.

Study Type

Interventional

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

    • North Carolina
      • Durham, North Carolina, United States, 27710
        • Duke Regional Hospital

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years and older (Adult, Older Adult)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Description

Inclusion Criteria:

Subjects eligible for this clinical study must fulfill all of the following:

  • Subject is 18 years of age or older.
  • Subject is scheduled for a MIS procedure:

    1. Laparoscopic Gastric Banding
    2. Laparoscopic Roux-en-Y Gastric Bypass
    3. Laparoscopic Sleeve Gastrectomy
    4. Laparoscopic Fundoplication Procedure (Nissen, Toupet, Dor, etc.)
    5. Laparoscopic Heller myotomy
    6. Laparoscopic paraesophageal hernia repair
    7. Laparoscopic gastric resection
  • Subject is able to comprehend and give informed consent for participation in this study.

Exclusion Criteria:

  • Subjects not eligible for this research study include those that have any of the following:

    • Subject is unable to comprehend and give informed consent for participation in this study.
    • Subject who are pregnant.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Basic Science
  • Allocation: N/A
  • Interventional Model: Single Group Assignment
  • Masking: None (Open Label)

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Experimental: EndoLift Liver Retractor
During surgery, the surgeon will use the new internal liver retractor device. The device will retract the subject's liver out of the way and help the surgeon see better during the surgery. The device is placed inside the abdomen during the surgery. It is "clipped" onto 2 safe surfaces inside the abdomen. The device is removed before the surgery ends.
During the surgery, the surgeon will use the new internal liver retractor device. The device will retract the liver out of the way and help the surgeon see better during the surgery. The device is placed inside the abdomen during the surgery. It is "clipped" onto 2 safe surfaces inside the abdomen. The device is removed before the surgery ends.

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Safety
Time Frame: Day 1 post-op

The primary study endpoint will be to establish the safety of using the EndoLift Liver Retractor as an internal laparoscopic liver retraction device.

Safety will be established by lack of serious events. Events are defined as adverse if they require change in the operative course, a device specific complication and/or association with prolongation of hospital stay.

Day 1 post-op

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Effective use of the EndoLift Liver Retractor
Time Frame: Up to 6 hours during the operative procedure

The effective use of the EndoLift Liver Retractor as a liver retraction device during surgery will be considered a "success". If there is a need to use any additional equipment to retract the liver during the surgery, the subject will be scored a "failure".

Study success will be declared if at least 80% of subjects are scored a "success".

Up to 6 hours during the operative procedure

Other Outcome Measures

Outcome Measure
Measure Description
Time Frame
Physician satisfaction
Time Frame: Day 1 Post-op

Physician satisfaction and surgeon recommendations for 'best practices' during utilization of the EndoLift Liver Retractor will be assessed by questionnaire.

Study outcomes will be measured within the hospitalization period.

Day 1 Post-op

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Sponsor

Collaborators

Investigators

  • Principal Investigator: Dana Portenier, MD, Duke University

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start

November 1, 2011

Primary Completion (Actual)

February 1, 2014

Study Completion (Actual)

February 1, 2014

Study Registration Dates

First Submitted

November 22, 2013

First Submitted That Met QC Criteria

December 6, 2013

First Posted (Estimate)

December 11, 2013

Study Record Updates

Last Update Posted (Estimate)

August 5, 2015

Last Update Submitted That Met QC Criteria

August 3, 2015

Last Verified

August 1, 2015

More Information

Terms related to this study

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Laparoscopic Sleeve Gastrectomy

Clinical Trials on EndoLift Liver Retractor

3
Subscribe