Prospective Evaluation of Safety and Efficacy Vertebral Drug-eluting Stent System (PESS)
Prospective Multi-center Single-arm Target Value Clinical Trial for Evaluating Clinical Use Safety and Efficacy of the Firehorus Vertebral Artery Rapamycin-target-eluting Stent System
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Beijing
-
Beijing, Beijing, China, 100010
- Beijing Tiantan Hospital
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Aged over 18 years (including 18 years old), and under 80 years old (including 80 years old), male / Pregnancy Test ( -) female
- Patients with symptomatic vertebral artery stenosis not responding to drug therapy (defined as stroke or TIA occurred within 90 days, the patient is using at least one antithrombotic drug and receiving interventions for other vascular risk factors, such as antihypertensive therapy or lipid-lowering therapy for hypertensionor high cholesterol when stroke or TIA occurs)
- DSA angiography indicated target lesion stenosis ≥ 50% (the degree of stenosis is determined according to the WASID method)
- Length of vascular lesion ≤ 21mm
- Modified Rankin score < 3
- Suiform for placing with vertebral artery rapamycin-eluting stent, voluntary to receive follow-up and sing the informed consent
Exclusion Criteria:
- There is a series of stenosis lesion within the target lesion region
- TIA or non- disabling stroke (such as atrial fibrillation, etc.) caused by other factors other than vertebral artery stenosis
- The target lesion area had received previous surgery or endovascular treatment
- Combined with severe systemic disease or with other disease with the potential risk to cause fatal sudden illness, or the subject with life expectancy <2 years
- Unsuitable / intolerable to dual antiplatelet therapy
- Suffered from cerebral infarction and severe neurological dysfunction related to the responsible blood vessels (modified Rankin score ≥ 3 points)
- Experienced severe myocardial infarction within 2 weeks
- Accompanied by other intracranial lesions, such as intracranial hemorrhage, aneurysm, arteriovenous malformations, brain tumors, etc.
- Arterial dissection, moyamoya disease, arteritis active, unexplained non- atherosclerotic stenosis
- Serious target vessel tortuosity / calcification, leading to not suitable for stenting / lesion can not be expanded
- Severe renal impairment, or allergic to or resistant to contrast agent, rapamycin (Rapamycin) and its derivatives, cobalt based alloys, polylactic acid ;
- Patients participated in other drugs or equipment and have not reached the endpoint
- The patient or their family members do not agree to sign an informed consent form
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Experimental
Drug-eluting stent
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
rate of in-stent restenosis
Time Frame: 6 months (± 30 days) after procedure
|
DSA angiography performed after 6 months (± 30 days) showed the occurrence of in-stent restenosis and the restenosis rate ≥ 50%;
|
6 months (± 30 days) after procedure
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Immediate stent implantation success rate
Time Frame: Immediate after the procedure
|
postoperative angiography immediately after implantation of Firehorus indicated that residual stenosis ≤ 20% (the degree of stenosis is determined according to the WASID method)
|
Immediate after the procedure
|
|
Any death or stroke related to the treated area
Time Frame: 1 year
|
Any death or stroke related to the treated area supplied by the target blood vessels during the follow-up period.
|
1 year
|
|
Any death or stroke
Time Frame: 1 year
|
Any death or stroke during the follow-up period
|
1 year
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Study Chair: Zhongrong Miao, PhD,MD, Beijing Tiantan Hospital
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- BTH-PESS
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.