Diagnostic Accuracy of CT-FFR Compared to Invasive Coronar Angiography With Fractional Flow Reserve
Diagnostic Accuracy of Coronary Computed Tomographic Angiography Derived Fractional Flow Reserve Compared to Invasive Coronar Angiography With Fractional Flow Reserve
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Trondheim, Norway
- St Olavs Hospital, Klinikk for hjertemedisin
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion criteria
- Proven stenosis by CCTA that require further investigation with invasive coronary angiography i.e. patients with estimated stenosis ≥30- 50%.
- Informed consent
Exclusion Criteria:
- Patients with unstable coronary artery disease.
- Previously treated with PCI or coronary surgery.
- Severe renal impairment i.e. GFR <30ml / min
- Contrast allergy
- Contraindication to adenosine / nitroglycerin / beta-blocker
- BMI> 40
- Patients referred on the basis of technically unsuccessful CTA, motion artifact or similar
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Diagnostic
- Allocation: Non-Randomized
- Interventional Model: Single Group Assignment
- Masking: Single
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: CT-FFR
Analyse With New CT-FFR Method
|
Invasive FFR and CCTA With CT-FFR
|
|
Active Comparator: Stress echocardiography
Analyse With invasive FFR and stress echocardiography
|
Stress echocardiography and invasive FFR
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
CT- FFR values by New Method as a dichotomous variable
Time Frame: 4 weeks
|
Determining the diagnostic accuracy of CT-FFR values obtained by the new method compared with invasive coronary angiography with fractional flow reserve
|
4 weeks
|
|
Worsening regional wall motion abnormality
Time Frame: 4 weeks
|
Determining the diagnostic accuracy of invasive FFR with comprehensive stress echocardiographic techniques
|
4 weeks
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Investigators
Investigators
- Study Director: Petter Aadahl, MD, PhD, Norwegian University of Science and Technology
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 2016/1609
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.