Distance From the Glottis to the Grille in Children
Distance From the Glottis to the Grille in Children: Ambu AuraGainTM , I-gel, Air-Q Intubating Laryngeal Airway as Intubation Conduits
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Seoul, Korea, Republic of, 110-744
- Seoul National University Hospital
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- children < 7 years old undergoing elective surgery
Exclusion Criteria:
- difficult airway
- BMI> 30kg/m2
- emergency operation
- cervical spine disease
- history of esophageal disease and surgery
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Other
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Ambu AuraGain
Ambu AuraGain is inserted in children undergoing general anesthesia.
The size of AuraGain is as follows: size 1 for children <5 kg, size 1.5 for 5-10kg, size 2 for 10-20kg, size 2.5 for 20-30kg.
Fiberoptic bronchoscope will be performed to measure the distance between the grill and vocal cord.
|
Distance from grille (the end of shaft in supraglottic airway) to glottis is measured using FOB
Other Names:
|
|
Experimental: I-gel
I-gel is inserted in children undergoing general anesthesia.
The size of I-gel is as follows: size 1 for children weighing 2-5kg, size 1.5 for 5-12kg, size 2 for 10-25kg, size 2.5 for 25-35kg.
Fiberoptic bronchoscope will be performed to measure the distance between the grill and vocal cord.
|
Distance from grille (the end of shaft in supraglottic airway) to glottis is measured using FOB
Other Names:
|
|
Experimental: Air-Q intubating laryngeal airway (ILA)
Air-Q ILA is inserted in children undergoing general anesthesia.
The size of Air-Q ILA is as follows: size 1 for children between 4-7 kg, size 1.5 for 7-17kg, size 2 for 17-30kg, size 2.5 for 30-50kg.
Fiberoptic bronchoscope will be performed to measure the distance between the grill and vocal cord.
|
Distance from grille (the end of shaft in supraglottic airway) to glottis is measured using FOB
Other Names:
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
The distance from grille to glottis
Time Frame: 30 seconds after each supraglottic airway insertion
|
The distance from grille to glottis is measured using fiberoptic bronchoscopy
|
30 seconds after each supraglottic airway insertion
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
FOB view
Time Frame: 30 seconds after each supraglottic airway insertion
|
score 1: no visible glottis, score 2: visible glottis and anterior epiglottis, score 3: visible glottis and posterior epiglottis, and score 4: only glottis visible
|
30 seconds after each supraglottic airway insertion
|
|
Ventilation score
Time Frame: 30 seconds after each supraglottic airway insertion
|
no air leak in airway pressure of 15 cmH2O / bilateral chest wall movement/ normal waveform of capnography
|
30 seconds after each supraglottic airway insertion
|
Collaborators and Investigators
Sponsor
Sponsor
Publications and helpful links
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
Other Study ID Numbers
- H1704-133-848
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on General Anesthesia
-
NCT02492282CompletedAnesthesia, General | Anesthesia, Intravenous
-
NCT03432351CompletedPediatric Anesthesia | General Anesthesia | Electroencephalography
-
NCT07513870CompletedAnesthesia, General | Cesarean Section | Anesthesia, Intravenous
-
NCT03431532CompletedGeneral Anesthesia | Regional Anesthesia | Immune Function
-
NCT06352606RecruitingSpinal Anesthesia | General Anesthesia | Inguinal Herniorrhaphy | Neonates
-
NCT02529501CompletedSpinal Anesthesia | Outpatient Surgery | Short General Anesthesia
-
NCT04721054CompletedGeneral Anesthesia | Epidural Anesthesia
-
NCT06380244RecruitingAnesthesia, General | Analgesics, Opioid | Anesthesia, Endotracheal
-
NCT05409885CompletedAnesthesia, General | Anesthesia, Spinal | Umbilical Cord
-
NCT01604226UnknownGeneral Anesthesia | Total Intravenous Anesthesia | Bispectral Index Monitoring
Clinical Trials on fiberoptic bronchoscope
-
NCT01113723Completed
-
NCT02669550CompletedTherapeutic Procedural Complication
-
NCT03003585CompletedIntraocular Pressure | Intubation Complication
-
NCT03759561Completed
-
NCT03392818UnknownTherapeutic Procedural Complication
-
NCT06775184Not yet recruitingSupraglottic Airway Devices Position
-
NCT07107893CompletedLung Diseases | Lung Cancer