Miniscrews Primary Stability
Multicentric Clinical Study Protocol on Primary Stability of STORM® Miniscrew
Orthodontic Miniscrew primary stability is essential for success and long term results.
The aim of the present study is to evaluate Bone Properties and Torque insertion values and how they could be related to primary stability and success rate of miniscrew.
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Anticipated)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- patient who need ortho treatment with miniscrew
- permanent dentition
Exclusion Criteria:
- bone pathologies
- systemic disease
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Single
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Active Comparator: group 1:maxillary insertion
Orthodontic miniscrew insertion; maxillary insertion.
buccal
|
orthodontic treatment using miniscrews as anchorage reinforcement
|
|
Active Comparator: group 2: mandible insertion
Orthodontic miniscrew insertion; mandible insertion.
|
orthodontic treatment using miniscrews as anchorage reinforcement
|
|
Active Comparator: group 3: palatal insertion
Orthodontic miniscrew insertion; palatal insertion
|
orthodontic treatment using miniscrews as anchorage reinforcement
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Success
Time Frame: From the moment the screw will be placed, measuring maximum insertion torque, through study completion, when the screws will be removed, measuring removal torque. An average duration of screw of 10-12 months is expected.
|
How many screws don't fail.
Success if the screw remain stable until the end of biomechanics applied.
|
From the moment the screw will be placed, measuring maximum insertion torque, through study completion, when the screws will be removed, measuring removal torque. An average duration of screw of 10-12 months is expected.
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
MIT
Time Frame: The date when, for each patient, the miniscrew will be inserted. Registered as the insertion date (day). Up to 12 months from orthodontic therapy beginning. The event is determined from date of randomization list creation until the day of screw insertion
|
miniscrew maximum insertion torque: The moment when the screw will be placed, the maximum insertion torque will be registered at the insertion time, with a analogical screwdriver, measured in Ncm
|
The date when, for each patient, the miniscrew will be inserted. Registered as the insertion date (day). Up to 12 months from orthodontic therapy beginning. The event is determined from date of randomization list creation until the day of screw insertion
|
|
MRT
Time Frame: The date when, for each patient,the miniscrew will be removed.Registered as the removal date (day).Up to 24 months after miniscrew insertion.The event is determined from date of randomization list creation until the day of screw removal, up to 48 months
|
maximum removal torque.
Maximum removal torque will be recorded using an analogical screwdriver at the completion of screw insertion.
MRT is a unique value expressed in Ncm measured when the screws will be removed.
|
The date when, for each patient,the miniscrew will be removed.Registered as the removal date (day).Up to 24 months after miniscrew insertion.The event is determined from date of randomization list creation until the day of screw removal, up to 48 months
|
Other Outcome Measures
Other Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Cortical thickness
Time Frame: At the beginning of the orthodontic treatment, before any dental movement occurred. Time frame is from randomization list and beginning of orthodontic treatment, up to 24 months.
|
cortical thickness measured in mm, a.
Both values will be evaluated on CBCT images acquired before orthodontic treatment beginning
|
At the beginning of the orthodontic treatment, before any dental movement occurred. Time frame is from randomization list and beginning of orthodontic treatment, up to 24 months.
|
|
Marrow bone density
Time Frame: At the beginning of the orthodontic treatment, before any dental movement occurred. Time frame is from randomization list and beginning of orthodontic treatment, up to 24 months.
|
marrow/cortical bone density measured with HU values.
Images will be evaluated with dedicated software for image analysis
|
At the beginning of the orthodontic treatment, before any dental movement occurred. Time frame is from randomization list and beginning of orthodontic treatment, up to 24 months.
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Publications and helpful links
General Publications
- Migliorati M, Drago S, Dalessandri D, Lagazzo A, Gallo F, Capurro M, Silvestrini-Biavati A. On the stability efficiency of anchorage self-tapping screws: Ex vivo experiments on miniscrew implants used in orthodontics. J Mech Behav Biomed Mater. 2018 May;81:46-51. doi: 10.1016/j.jmbbm.2018.02.019. Epub 2018 Feb 19.
- Watanabe T, Miyazawa K, Fujiwara T, Kawaguchi M, Tabuchi M, Goto S. Insertion torque and Periotest values are important factors predicting outcome after orthodontic miniscrew placement. Am J Orthod Dentofacial Orthop. 2017 Oct;152(4):483-488. doi: 10.1016/j.ajodo.2017.01.026.
- Inoue M, Kuroda S, Yasue A, Horiuchi S, Kyung HM, Tanaka E. Torque ratio as a predictable factor on primary stability of orthodontic miniscrew implants. Implant Dent. 2014 Oct;23(5):576-81. doi: 10.1097/ID.0000000000000138.
- Watanabe H, Deguchi T, Hasegawa M, Ito M, Kim S, Takano-Yamamoto T. Orthodontic miniscrew failure rate and root proximity, insertion angle, bone contact length, and bone density. Orthod Craniofac Res. 2013 Feb;16(1):44-55. doi: 10.1111/ocr.12003. Epub 2012 Sep 3.
- Migliorati M, Drago S, Gallo F, Amorfini L, Dalessandri D, Calzolari C, Benedicenti S, Silvestrini-Biavati A. Immediate versus delayed loading: comparison of primary stability loss after miniscrew placement in orthodontic patients-a single-centre blinded randomized clinical trial. Eur J Orthod. 2016 Dec;38(6):652-659. doi: 10.1093/ejo/cjv095. Epub 2016 Jan 4.
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Anticipated)
Primary Completion
Study Completion (Anticipated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Other Study ID Numbers
Other Study ID Numbers
- GE-BS-MA MRCT
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.