Right Colon Polyp Miss Rates of Water Exchange and Carbon Dioxide Insufflation Colonoscopy
Comparing Right Colon Adenoma and Hyperplastic Polyp Miss Rate in Colonoscopy Using Water Exchange and Carbon Dioxide Insufflation: A Prospective Randomized Controlled Trial
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Taoyuan, Taiwan
- Evergreen General Hospital
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Consecutive patients aged 45 years or older undergoing colonoscopy for screening, surveillance, and positive FIT will be considered for enrollment.
Exclusion Criteria:
- familial adenomatous polyposis and hereditary non-polyposis CRC syndrome, personal history of CRC or inflammatory bowel disease, previous colonic resection, obstructive lesions of the colon, gastrointestinal bleeding, allergy to fentanyl, midazolam or propofol, American Society of Anesthesiology (ASA) classification of physical status grade 3 or higher, mental retardation, pregnancy, and refusal to provide a written informed consent.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Single
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Active Comparator: Water exchange (WE) colonoscopy
Water exchange will be used during colonoscopy insertion.
Upon arriving at the cecum, CO2 will be opened.
The scope will be withdrawn to the hepatic flexure.
All polyps identified will be resected (colon polypectomy).
The scope will be reinserted into the cecum by the first endoscopist.
A tandem inspection of right colon will be performed by a second endoscopist.
All polyps found herein will be counted as the missed polyps.
After the second withdrawal to the distal hepatic flexure, the remainder of the colon will be examined in a standard manner by the first endoscopist.
|
Polyp search and resection will be performed during the withdrawal phase in both groups.
Insertion polypectomy will not be performed.
All proximal colon polyps will be removed irrespective of their size and appearance.
|
|
Active Comparator: CO2 insufflation colonoscopy
The colonoscopy is performed in the usual fashion, with minimal insufflation required to aid insertion.
Cleaning will be performed entirely during withdrawal.
Upon arriving at the cecum, CO2 insufflation will be used and the scope will be withdrawn to the hepatic flexure.
All polyps identified will be resected (colon polypectomy).
Then the scope will be reinserted into the cecum by the first endoscopist using CO2.
A tandem inspection of the right colon will then be performed by a second endoscopist.
All polyps found herein will be counted as the missed polyps.
After the second withdrawal to the mark of distal hepatic flexure, the remainder of the colon will be examined in a standard manner by the first endoscopist.
|
Polyp search and resection will be performed during the withdrawal phase in both groups.
Insertion polypectomy will not be performed.
All proximal colon polyps will be removed irrespective of their size and appearance.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Percentage of Adenomas and Hyperplastic Polyps Missed During Initial Right Colon Examination
Time Frame: One day
|
Lesions detected on the tandem (second) right colon examination are used for the calculation of adenoma and hyperplastic polyp miss rate.
Right colon adenoma miss rate (AMR) and right colon hyperplastic polyp miss rate (HPMR) are calculated as the number of adenomas and hyperplastic polyps detected during the second right colon examination divided by the total number of adenoma and hyperplastic polyps detected during both the first and second right colon examinations.
|
One day
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Chiliang Cheng, MD, Evergreen General Hospital
Publications and helpful links
General Publications
- Zhao S, Wang S, Pan P, Xia T, Chang X, Yang X, Guo L, Meng Q, Yang F, Qian W, Xu Z, Wang Y, Wang Z, Gu L, Wang R, Jia F, Yao J, Li Z, Bai Y. Magnitude, Risk Factors, and Factors Associated With Adenoma Miss Rate of Tandem Colonoscopy: A Systematic Review and Meta-analysis. Gastroenterology. 2019 May;156(6):1661-1674.e11. doi: 10.1053/j.gastro.2019.01.260. Epub 2019 Feb 6.
- le Clercq CM, Bouwens MW, Rondagh EJ, Bakker CM, Keulen ET, de Ridder RJ, Winkens B, Masclee AA, Sanduleanu S. Postcolonoscopy colorectal cancers are preventable: a population-based study. Gut. 2014 Jun;63(6):957-63. doi: 10.1136/gutjnl-2013-304880. Epub 2013 Jun 6.
- Fuccio L, Frazzoni L, Hassan C, La Marca M, Paci V, Smania V, De Bortoli N, Bazzoli F, Repici A, Rex D, Cadoni S. Water exchange colonoscopy increases adenoma detection rate: a systematic review with network meta-analysis of randomized controlled studies. Gastrointest Endosc. 2018 Oct;88(4):589-597.e11. doi: 10.1016/j.gie.2018.06.028. Epub 2018 Jul 5.
- Leung FW, Koo M, Cadoni S, Falt P, Hsieh YH, Amato A, Erriu M, Fojtik P, Gallittu P, Hu CT, Leung JW, Liggi M, Paggi S, Radaelli F, Rondonotti E, Smajstrla V, Tseng CW, Urban O. Water Exchange Produces Significantly Higher Adenoma Detection Rate Than Water Immersion: Pooled Data From 2 Multisite Randomized Controlled Trials. J Clin Gastroenterol. 2019 Mar;53(3):204-209. doi: 10.1097/MCG.0000000000001012.
- Cheng CL, Kuo YL, Hsieh YH, Tang JH, Leung FW. Comparison of Right Colon Adenoma Miss Rates Between Water Exchange and Carbon Dioxide Insufflation: A Prospective Randomized Controlled Trial. J Clin Gastroenterol. 2021 Nov-Dec 01;55(10):869-875. doi: 10.1097/MCG.0000000000001454.
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- EGH-2019
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.