A Multicenter Study Evaluating the Effectiveness of Endo.Angel in Improving the Quality of Colonoscopy
A Prospective, Randomized, Single-blind, Parallel-controlled Multicenter Study Evaluating the Effectiveness of Endo.Angel in Improving the Quality of Colonoscopy
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Anticipated)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Hubei
-
Wuhan, Hubei, China, 430060
- Renmin Hospital of Wuhan University
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Men or women over the age of 18 years old;
- Ability to read, understand and sign informed consent;
- The investigator believes that the subject understands the flow of the clinical study and is willing and able to complete all the research procedures and follow-up visits in conjunction with the research procedure.
Exclusion Criteria:
- Colonoscopy patients with absolute contraindications;
- patients with biopsy contraindications;
- inflammatory bowel disease, colorectal cancer, history of colorectal surgery;
- women during pregnancy or lactation;
- Patients with multiple polyposis syndrome;
- Patients with known or suspected intestinal obstruction or perforation
- Previously failed colonoscopy;
- The investigator believes that the subject is not suitable for high-risk disease or other special conditions in clinical trials.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Screening
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Double
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Exposed group
Patients will receive colonoscopy with assistance of Endo.Angel
|
Patients in exposed group will receive colonoscopy with assistance of Endo.Angel,a real-time quality monitoring system based on computer vision,which is used to monitor the velocity of insertion of the endoscope, record the time of insertion and withdrawal of the endoscope, and remind endoscopists of the blind areas caused by intestinal segment slipping.
|
|
Sham Comparator: Non-exposed group
Patients will receive colonoscopy without assistance of Endo.Angel
|
Patients in non-exposed group will receive colonoscopy without assistance of Endo.Angel.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Adenoma detection rate
Time Frame: 3 months.
|
The numerator is the number of cases of adenoma detected by colonoscopy, and the denominator is the total number of cases of patients undergoing colonoscopy.
|
3 months.
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
The mean number of polyps per procedure
Time Frame: 3 months.
|
The numerator is the total number of polyps detected by colonoscopy, and the denominator is the total number of patients undergoing colonoscopy.
|
3 months.
|
|
Polyp Detection Rate
Time Frame: 3 months.
|
The numerator is the number of patients with polyps detected by colonoscopy, and the denominator is the total number of patients receiving colonoscopy.
|
3 months.
|
|
The mean number of adenomas per procedure
Time Frame: 3 months.
|
The numerator is the total number of adenomas detected by colonoscopy, and the denominator is the total number of patients undergoing colonoscopy
|
3 months.
|
|
Detection rate of large, small and minimal polyps
Time Frame: 3 months.
|
The numerator was the number of patients with large (≥10 mm), small (4-9 mm), and minimal(≤5 mm) polyps detected by colonoscopy, and the denominator was the total number of patients receiving colonoscopy
|
3 months.
|
|
The mean number of large, small and minimal polyps per procedure
Time Frame: 3 months.
|
The numerator was the number of large (≥10 mm), small (4-9 mm), and minimal (≤5 mm) polyps detected by colonoscopy, and the denominator was the total number of patients receiving colonoscopy
|
3 months.
|
|
Detection rate of large, small and minimal adenomas
Time Frame: 3 months.
|
The numerator was the number of patients with large (≥10 mm), small (4-9 mm), and minimal(≤5 mm) adenomas detected by colonoscopy, and the denominator was the total number of patients receiving colonoscopy
|
3 months.
|
Collaborators and Investigators
Sponsor
Sponsor
Study record dates
Study Major Dates
Study Start (Anticipated)
Study Start
Primary Completion (Anticipated)
Primary Completion
Study Completion (Anticipated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- EA-18-003
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.