FANTOM ENCORE Sirolimus-eluting Bioresorbable Scaffold for Treatment of De-novo CAD: the ENCORE-I Study
Safety and Efficacy of the FANTOM ENCORE Sirolimus-eluting Bioresorbable Scaffold for Treatment of De-novo Coronary Artery Disease: the ENCORE-I Study
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Up to 50 consecutive participants with de-novo non-complex obstructive coronary lesions and non-ST elevation acute coronay syndromes or stable angina pectoris will be included in the Netherlands and Belgium.
Device performance and behaviour will be assessed by angiography and optical coherence tomography at the index procedure and at 13 months follow-up.
Study Type
Study Type
Enrollment (Anticipated)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Joost Daemen, MD, PhD
- Phone Number: +31 10 703 5260
- Email: j.daemen@erasmusmc.nl
Study Locations
-
-
-
Genk, Belgium
- Not yet recruiting
- Ziekenhuis Oost-Limburg
-
Contact:
- Jo Dens, Prof. Dr.
-
Leuven, Belgium
- Not yet recruiting
- Universitair Ziekenhuis Leuven
-
Contact:
- Tom Adriaenssens, Prof. Dr.
-
-
-
-
-
Rotterdam, Netherlands
- Recruiting
- Erasmus Medical Center
-
Contact:
- Joost Daemen, MD;PhD
- Phone Number: Tel: +31 10 703 5260
- Email: j.daemen@erasmusmc.nl
-
Contact:
- Maria Natalia Tovar Forero, MD
- Phone Number: Tel: +31 10 703 8896
- Email: m.tovarforero@erasmusmc.nl
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- 18 years or older
- Stable angina, unstable angina or documented silent ischemia (invasive or non-invasive test) or non-ST segment elevation acute myocardial infarction.
- De-novo non-complex coronary obstructive lesions (>50% stenosis as assessed by quantitative coronary analysis (QCA))
- The patient is willing and able to comply with the specified follow-up evaluations.
- Reference vessel diameter (RVD) ≥ 2.5 mm and ≤ 4.0 mm by QCA.
- During pre-dilatation, the pre-dilatation balloon is uniformly expanded to the full intended diameter.
- Target segment suitable for OCT imaging
Exclusion Criteria:
- Target vessel with a distal Thrombolysis In Myocardial Infarction (TIMI) flow 0 or 1.
- Target lesion located within 5.0 mm of vessel origin.
- Lesion type ACC/AHA C.
- Heavily calcified lesion
- Severe tortuosity
- Target lesion is located in or supplied by an arterial or venous bypass graft.
- Target lesion requires treatment with a device other than the pre-dilatation balloon prior to scaffold placement (including but not limited to directional coronary atherectomy, excimer laser, rotational atherectomy, etc.).
- Unsuccessful pre-dilatation, defined as a residual diameter stenosis ≥ 30%, assessed by QCA.
- Planned future revascularization of non-culprit lesions.
- Presence of another device (stent or scaffold) located within the same segment (5mm from the target lesion borders).
- Patient is currently participating in another study with an investigational device or an investigational drug and has not completed the entire follow-up period.
- Impaired renal function (eGFR <30ml/min).
- Patient has a contraindication for the use of double antiplatelet therapy for at least 12 months.
- Pregnant or breastfeeding patients.
- Patient has a known allergy to contrast medium, sirolimus, Tyrosine-derived polycarbonate or other structurally related compounds.
- Patient is receiving chronic oral or intravenous immunosuppressive therapy or has known life-limiting immunosuppressive or autoimmune disease (diabetes mellitus is not an exclusion criteria).
- Patient has a co-morbidity, which reduces life expectancy to ≤ 24 months, or social-economic factors making compliance with the study requirements difficult.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Other
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Other: Single arm
Fantom Encore Bioresorbable scaffold implantation
|
Fantom Encore Bioresorbable scaffold implantation
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Device-Oriented Composite Endpoint (DOCE)
Time Frame: 12 months
|
A composite of cardiac death, target vessel-related non-fatal myocardial infarction (MI) and clinically-driven target lesion revascularization(CD-TLR).
|
12 months
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Subcomponents of DOCE
Time Frame: 30 days, 6, 12, 24, 36, 48 and 60 months
|
Subcomponents of the Device-Oriented Composite Endpoints
|
30 days, 6, 12, 24, 36, 48 and 60 months
|
|
Target vessel revascularization (TVR)
Time Frame: 30 days, 6, 12, 24, 36, 48 and 60 months
|
Target vessel revascularization
|
30 days, 6, 12, 24, 36, 48 and 60 months
|
|
Definite or probable stent thrombosis (ST)
Time Frame: 30 days, 6, 12, 24, 36, 48 and 60 months
|
Stent thrombosis
|
30 days, 6, 12, 24, 36, 48 and 60 months
|
Other Outcome Measures
Other Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Angiographic outcomes at baseline
Time Frame: 0 days
|
Acute gain
|
0 days
|
|
Angiographic outcomes at baseline
Time Frame: 0 days
|
acute recoil
|
0 days
|
|
Angiographic outcomes at baseline
Time Frame: 0 days
|
Incidence of procedural complications (dissection >B, perforation, vessel closure, slow flow or no-reflow, intra-procedure scaffold thrombosis)
|
0 days
|
|
Angiographic outcomes at follow-up
Time Frame: 13 months
|
In-device and in-segment late lumen loss (LLL)
|
13 months
|
|
Angiographic outcomes at follow-up
Time Frame: 13 months
|
In-device and in-segment binary restenosis rate
|
13 months
|
|
Device performance
Time Frame: 0 days
|
Device success
|
0 days
|
|
Device performance
Time Frame: 0 days
|
Procedural success
|
0 days
|
|
Optical coherence tomography outcomes at baseline
Time Frame: 0 days
|
Incomplete strut apposition (ISA)
|
0 days
|
|
Optical coherence tomography outcomes at baseline
Time Frame: 0 days
|
Scaffold expansion
|
0 days
|
|
Optical coherence tomography outcomes at baseline
Time Frame: 0 days
|
Scaffold eccentricity
|
0 days
|
|
Optical coherence tomography outcomes at baseline
Time Frame: 0 days
|
Scaffold symmetry index
|
0 days
|
|
Optical coherence tomography outcomes at baseline
Time Frame: 0 days
|
Edge dissection
|
0 days
|
|
Optical coherence tomography outcomes at baseline
Time Frame: 0 days
|
In-device and in-segment endothelial shear stress
|
0 days
|
|
Optical coherence tomography outcomes at follow-up
Time Frame: 13 months
|
Neointima thickness
|
13 months
|
|
Optical coherence tomography outcomes at follow-up
Time Frame: 13 months
|
Percentage of patent struts
|
13 months
|
|
Optical coherence tomography outcomes at follow-up
Time Frame: 13 months
|
Percentage of uncovered struts
|
13 months
|
|
Optical coherence tomography outcomes at follow-up
Time Frame: 13 months
|
Persistent ISA
|
13 months
|
|
Optical coherence tomography outcomes at follow-up
Time Frame: 13 months
|
Acquired ISA
|
13 months
|
|
Optical coherence tomography outcomes at follow-up
Time Frame: 13 months
|
Scaffold eccentricity index
|
13 months
|
|
Optical coherence tomography outcomes at follow-up
Time Frame: 13 months
|
Scaffold symmetry index
|
13 months
|
|
Optical coherence tomography outcomes at follow-up
Time Frame: 13 months
|
In-device and in-segment late lumen area loss
|
13 months
|
|
Optical coherence tomography outcomes at follow-up
Time Frame: 13 months
|
In-device and in-segment binary restenosis rate.
|
13 months
|
|
Optical coherence tomography outcomes at follow-up
Time Frame: 13 months
|
In-device and in-segment endothelial shear stress
|
13 months
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Investigators
Investigators
- Principal Investigator: Joost Daemen, MD, PhD, Erasmus Medical Center
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Anticipated)
Primary Completion
Study Completion (Anticipated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
Other Study ID Numbers
- ENCORE-I
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.