Correlation Analysis of Lens Nucleus Density and Surgical Parameters Based on Ss-oct and Scheimpflug Technology
Correlation Analysis of Lens Nucleus Density and Surgical Parameters Based on Long-range Swept-source Optical Coherence Tomography and Scheimpflug Technology
Study Overview
Status
Status
Conditions
Conditions
Detailed Description
Study Type
Study Type
Enrollment (Anticipated)
Enrollment
Contacts and Locations
Study Contact
Study Contact
- Name: Lulu Chen
- Phone Number: 19883736563
- Email: 2951148901@qq.com
Study Locations
-
-
Zhejiang
-
Wenzhou, Zhejiang, China, 325027
- Ophthalmology and Optometry Hospital
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- ADULT
- OLDER_ADULT
- CHILD
Accepts Healthy Volunteers
Genders Eligible for Study
Sampling Method
Study Population
Description
Inclusion Criteria:
- Age-related cataracts performed by the same surgeon in our hospital;
- Pupil diameter can be enlarged more than 6 millimetre.
Exclusion Criteria:
- The pupil diameter cannot be dilated greater than 6mm;
- previously ocular surgery or laser treatment;
- history of ocular trauma;
- other ocular diseases such as keratoconus, glaucoma and retinal detachment;
- corneal opacities caused by leucoma, pterygium and other diseases;
- lens dislocation or complicated cataract surgery (any complications during/after the operations);
- poor fixation leading to low image quality or inability to cooperate with examinations.
Study Plan
How is the study designed?
Design Details
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Lens nuclear opalescence(NO) and nuclear colour (NC)
Time Frame: 2021.12.30
|
After the maximumly pupil dilation, the same experienced ophthalmologist examined all the eyes with slit-lamp digital cameras in dark conditions and scored the lens nuclear opalescence(NO) and nuclear colour (NC) on a scale of 0.1-6.9 according to LOCS III criteria.
|
2021.12.30
|
|
Pentacam mean nuclear density (PND)
Time Frame: 2021.12.30
|
After the maximumly pupil dilation, Pentacam HR was used to acquire the Scheimpflug images of the lens, and the average density reading for the entire nucleus provided by PNS function was defined as Pentacam mean nuclear density (PND), ranging from 0% to 100%.
|
2021.12.30
|
|
Mean nucleus density (MND) of the lens presented by IOL-Master 700
Time Frame: 2021.12.30
|
After the maximumly pupil dilation, the inspected eyes are asked to focus on the indicator light to obtain a high-definition image of the lens.
The image is derived to the ImageJ software, and the contour of the lens nucleus is manually drawn.
The pixel density of the image within the contour is measured, with a value range of 0-255.The mean pixel density within the region was used to represent the mean nucleus density (MND) of the lens presented by IOL-Master 700.For each eye, the SS-OCT nucleus density is defined as the average of six readings from the corresponding image.
|
2021.12.30
|
|
Intraoperative phacoemulsification parameters
Time Frame: 2021.12.30
|
The intraoperative phacoemulsification parameters on the Centurion phacoemulsification machine (Alcon) screen were recorded after surgery.
|
2021.12.30
|
Collaborators and Investigators
Sponsor
Sponsor
Publications and helpful links
General Publications
- Wang W, Zhang J, Gu X, Ruan X, Chen X, Tan X, Jin G, Wang L, He M, Congdon N, Liu Z, Luo L, Liu Y. Objective quantification of lens nuclear opacities using swept-source anterior segment optical coherence tomography. Br J Ophthalmol. 2022 Jun;106(6):790-794. doi: 10.1136/bjophthalmol-2020-318334. Epub 2021 Jan 13.
- Makhotkina NY, Berendschot TTJM, van den Biggelaar FJHM, Weik ARH, Nuijts RMMA. Comparability of subjective and objective measurements of nuclear density in cataract patients. Acta Ophthalmol. 2018 Jun;96(4):356-363. doi: 10.1111/aos.13694. Epub 2018 Mar 25.
- Lim SA, Shin JY, Chung SH. Useful Prediction of Phacodynamics by Scheimpflug Lens Densitometry in Patients over Age 70. Semin Ophthalmol. 2017;32(4):482-487. doi: 10.3109/08820538.2015.1120756. Epub 2016 Apr 19.
- Gupta M, Ram J, Jain A, Sukhija J, Chaudhary M. Correlation of nuclear density using the Lens Opacity Classification System III versus Scheimpflug imaging with phacoemulsification parameters. J Cataract Refract Surg. 2013 Dec;39(12):1818-23. doi: 10.1016/j.jcrs.2013.05.052.
- Chen D, Li Z, Huang J, Yu L, Liu S, Zhao YE. Lens nuclear opacity quantitation with long-range swept-source optical coherence tomography: correlation to LOCS III and a Scheimpflug imaging-based grading system. Br J Ophthalmol. 2019 Aug;103(8):1048-1053. doi: 10.1136/bjophthalmol-2018-312661. Epub 2018 Oct 12.
- Panthier C, de Wazieres A, Rouger H, Moran S, Saad A, Gatinel D. Average lens density quantification with swept-source optical coherence tomography: optimized, automated cataract grading technique. J Cataract Refract Surg. 2019 Dec;45(12):1746-1752. doi: 10.1016/j.jcrs.2019.07.033.
- Panthier C, Burgos J, Rouger H, Saad A, Gatinel D. New objective lens density quantification method using swept-source optical coherence tomography technology: Comparison with existing methods. J Cataract Refract Surg. 2017 Dec;43(12):1575-1581. doi: 10.1016/j.jcrs.2017.09.028.
Study record dates
Study Major Dates
Study Start (ANTICIPATED)
Study Start
Primary Completion (ANTICIPATED)
Primary Completion
Study Completion (ANTICIPATED)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (ACTUAL)
First Posted
Study Record Updates
Last Update Posted (ACTUAL)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- LZL nucleus density
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.