Relationship Between the Functional Movement Screen and Isokinetic Muscle Strength of Knee in Different Sport Branches
The Relationship Between The Functional Movement Screen and Isokinetic Muscle Strength of Knee in Different Sport Branches
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Contacts and Locations
Study Locations
-
-
Guneysu
-
Rize, Guneysu, Turkey, 53390
- Recep Tayyıp Erdogan University Guneysu Vocational School of Physical Therapy and Rehabilitation
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Child
- Adult
Accepts Healthy Volunteers
Sampling Method
Study Population
Description
Inclusion Criteria:
- Those who voluntarily agreed to participate in the study
- Have at least 3 years of licensed sports experience
Exclusion Criteria:
- Those who have had or have ongoing orthopedic problems in the last 6 months
Study Plan
How is the study designed?
Design Details
Number of groups / cohorts
Cohorts and Interventions
Group / CohortGroup / Cohort |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Functional Movement Screen and Isokinetic Muscle Evulation of Knee Muscles
Functional movement screen was evaluated with 7 basic parameters determined by Gray Cook Isokinetic muscle measurements were performed with an ISOMED 2000
|
FMS is an analysis system that evaluates muscle strength imbalance and functional performances on the dominant-non-dominant side in athletes.
It aims to detect stability and mobility that can be ignored in the asymptomatic active population and athletes.
It consists of 7 basic parameters determined by Gray Cook (Deep Squat, Hurdle Step, -In-line Lunge, Shoulder Mobility, Active Straight Leg Raise, Trunk Stability, Rotatory Stability).
The athletes were evaluated after giving verbal instructions to the athletes about the head, trunk, knee and foot positions.
For each parameter, the athletes were given points between 0-3 values.
The total score was determined as 21 points.
Completing the movement completely and without compensation was given 3 points, and 2 or 1 points were given according to the activation of the compensation mechanism and balance disorders.
In case of any pain during or at the end of the movement in the evaluated parameter, 0 points were given to the athletes.
The isokinetic knee flexor and extensor group muscle strengths of the athletes participating in the study were measured on the dominant and non-dominant sides.
Measurements were performed with an ISOMED 2000 (D&R Ferstl GmbH, Hemau, Germany) isokinetic measuring device.
The test protocol was adjusted to be concentric/concentric.
Measurements were made at angular velocities of 60°/sec and 180°/sec.
At an angular speed of 60°/sec, the athlete was asked to perform 10 repetitions of voluntary knee flexion/extension at maximum strength.
Then, after resting for 30 seconds, 30 repetitions of knee flexion/extension were performed at an angular velocity of 180°/sec.
Before starting the test in both angular speeds, 3 repetitive attempts were made to learn the movement.
The following parameters were evaluated at 60°/sec and 180°/sec angular speed.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Funtional Movement Screen (FMS)
Time Frame: 20 minutes
|
FMS is an analysis system that evaluates muscle strength imbalance and functional performances on the dominant-non-dominant side in athletes.
It aims to detect stability and mobility that can be ignored in the asymptomatic active population and athletes.
It consists of 7 basic parameters determined by Gray Cook (Deep Squat, Hurdle Step, -In-line Lunge, Shoulder Mobility, Active Straight Leg Raise, Trunk Stability, Rotatory Stability).
The athletes were evaluated after giving verbal instructions to the athletes about the head, trunk, knee and foot positions.
For each parameter, the athletes were given points between 0-3 values.
The total score was determined as 21 points.
Completing the movement completely and without compensation was given 3 points, and 2 or 1 points were given according to the activation of the compensation mechanism and balance disorders.
In case of any pain during or at the end of the movement in the evaluated parameter, 0 points were given to the athletes.
|
20 minutes
|
|
Isokinetic Measurement of Knee Muscles
Time Frame: 20 minutes
|
The isokinetic knee flexor and extensor group muscle strengths of the athletes participating in the study were measured on the dominant and non-dominant sides.
Measurements were performed with an ISOMED 2000 (D&R Ferstl GmbH, Hemau, Germany) isokinetic measuring device.
The test protocol was adjusted to be concentric/concentric.
Measurements were made at angular velocities of 60°/sec and 180°/sec.
At an angular speed of 60°/sec, the athlete was asked to perform 10 repetitions of voluntary knee flexion/extension at maximum strength.
Then, after resting for 30 seconds, 30 repetitions of knee flexion/extension were performed at an angular velocity of 180°/sec.
Before starting the test in both angular speeds, 3 repetitive attempts were made to learn the movement.
The following parameters were evaluated at 60°/sec and 180°/sec angular speed.
|
20 minutes
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Study Director: TUGBA BIRBEN, PhD, Recep Tayyıp Erdogan University Guneysu Vocational School of Physical Therapy and Rehabilitation
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 2017/23
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.