Chronic Evaluation of Novel Pacemaker System
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Estimated)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Imad Libbus, PhD
- Phone Number: 763-657-1480
- Email: imad@calyantech.com
Study Locations
-
-
Minnesota
-
Minneapolis, Minnesota, United States, 55455
- Recruiting
- University of Minnesota
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
- Older Adult
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Age 18 or above
- Willing and capable of providing informed consent
- Class I or IIa indication for implantation of a single-chamber ventricular pacemaker, according to ACC/AHA/HRS guidelines
- A life expectancy of at least one year, and is a suitable candidate based on overall health and well-being
Exclusion Criteria:
- Patients with complete AV block or other pacemaker-dependent conditions
Patients in whom a substernal device implant should be avoided:
- Any prior sternotomy;
- Any prior medical condition or procedure that leads to adhesions in the anterior mediastinal space;
- Any marked sternal abnormality, such as pectus excavatum or pectus carinatum
- Prior abdominal surgery in the epigastric region
- Planned sternotomy
- Prior or planned chest radiotherapy
- Hiatal hernia that distorts mediastinal anatomy
- Adhesions in the anterior mediastinal space
- Severe obesity so that subxiphoid/substernal tunneling cannot be safely performed
- Patients with severe RV dilation, gross hepatosplenomegaly, or severe obesity such that subxiphoidal/substernal tunneling cannot be safely performed
- Patients with a class III indication for a permanent pacemaker
- Patients with decompensated heart failure not due to bradycardia and expected to worsen with chronic RV pacing
- Patients with an implanted cardiac pacemaker, cardioverter defibrillator, cardiac resynchronization device, or neurostimulator device, or planned implantation of a cardioverter defibrillator, cardiac resynchronization device, or neurostimulator device
- Patients with a current or planned implantation of a substernal device, or any implanted device that would interfere with the implantation or operation of a substernal device
- Patients who have previously undergone an open-heart surgical procedure.
- Patients with an active infection
- Patient on chronic oral anticoagulation which cannot be temporarily discontinued for surgery
- Patients with a condition in which pericardial pacing would be difficult or impossible, such as acute pericarditis, chronic pericardial effusion or pericardial thickening or calcification, cardiac tamponade, or chronic restrictive pericarditis
- Patients who have tested positive for the COVID-19 in the past 3 months, or are currently showing symptoms consistent with COVID-19
- Women of childbearing potential who are or might be pregnant at the time of the study or breastfeeding
- Subjects with a life expectancy of less than 12 months
- Patients who are currently enrolled or planning to participate in any concurrent clinical study with an investigational therapy
- Patients with decompensated heart failure expected to worsen with chronic RV pacing
- Patients with COPD with oxygen dependence
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Device Feasibility
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Treatment
Chronic implantation of the Calyan pacemaker device
|
The Calyan pacemaker is a device designed for implantation in the chest below the xiphoid process, and includes a FlexArm containing stimulation and sensing electrodes.
The Calyan pacemaker is implanted using a set of delivery tools and clipped onto the xiphoid process; the FlexArm electrodes are oriented to make contact with the pericardial surface of the heart.
Pacing parameters are adjusted wirelessly with a tablet-based programmer that communicates with the Calyan pacemaker via secure Bluetooth.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Incidence of procedure and device related serious adverse events (SAEs)
Time Frame: 3 months
|
Rate of procedure and device related serious adverse events (SAEs) at 3 months post-implant.
|
3 months
|
|
Number of patients with successful chronic ventricular pacing
Time Frame: 3 months
|
Proportion of patients with successful chronic ventricular pacing, including successful pacemaker implantation and chronic capture of the ventricle, during the 3-month primary follow-up period.
|
3 months
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Study Director: Imad Libbus, PhD, Calyan Technologies
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Estimated)
Primary Completion
Study Completion (Estimated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- CT-05
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.