Exploratory Safety and Effectiveness Evaluation of Pulsed Field Ablation (PFA) by Balloon Catheter With TRUPULSE Generator for Treatment of Paroxysmal Atrial Fibrillation (PAF) (ZephIRE)
Exploratory Safety and Effectiveness Evaluation of Pulsed Field Ablation by a Balloon Catheter With the TRUPULSE Generator for Treatment of Paroxysmal Atrial Fibrillation (PAF)
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Study Contact
- Phone Number: +32479970505
- Email: nmacours1@its.jnj.com
Study Locations
-
-
-
Hasselt, Belgium, 3500
- Jessa Ziekenhuis - Campus Virga Jesse
-
Jette, Belgium, 1090
- UZ Brussel
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
- Older Adult
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Diagnosed with symptomatic Paroxysmal Atrial Fibrillation (PAF) defined as AF that terminates spontaneously or with intervention within 7 days of onset. This PAF is considered to be symptomatic if symptoms related to AF are experienced by the participant
- Selected for AF ablation procedure by pulmonary vein isolation (PVI)
- Willing and capable of providing consent
- Able and willing to comply with all pre-, post-, and follow-up testing and requirements
Exclusion Criteria:
- Previously known AF secondary to electrolyte imbalance, thyroid disease, or reversible or non-cardiac cause (example, documented obstructive sleep apnea, acute alcohol toxicity, morbid obesity [body mass index more than {>} 40 kilogram per square meter {kg/m^2}], renal insufficiency [with an estimated creatinine clearance less than {<}30 milliliter {mL}/minute {min}/1.73 meter {m}^2])
- Previous left atrium (LA) ablation or surgery
- Participants known to require ablation outside the pulmonary vein (PV) region (example, atrioventricular reentrant tachycardia, atrioventricular nodal re-entry tachycardia, atrial tachycardia, ventricular tachycardia and Wolff-Parkinson-White)
- Previously diagnosed with persistent AF (>7 days in duration)
- Severe dilatation of the LA (left anterior descending artery [LAD] >50 millimetre [mm] antero-posterior diameter or left atrium volume index [LAVi] >48 [mL/m^2] in case of transthoracic echocardiography [TTE])
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Pulsed Field Ablation by a Balloon Catheter with the TRUPULSE Generator
Participants with paroxysmal atrial fibrillation (PAF) will undergo pulmonary vein (PV) ablation procedure with investigational system (pulsed field ablation balloon catheter used in combination with the TRUPULSE generator) until pulmonary vein isolation (PVI) is achieved and confirmed via entrance block.
If PVI cannot be achieved with the investigational system, a commercially approved Biosense Webster (recommended) catheter and compatible commercially available generator can be used to complete the procedure.
|
Pulsed field ablation balloon catheter and TRUPULSE generator will be used for PV ablation.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Percentage of Participants with Primary Adverse Events (PAEs)
Time Frame: Up to 3 months post-procedure
|
Percentage of participants with PAEs will be reported.
PAE's will include the following adverse events: atrio-esophageal fistula, phrenic nerve paralysis, cardiac tamponade/perforation, severe pulmonary vein stenosis (PVS), device or procedure related death, stroke/cerebrovascular accident (CVA), major vascular access complication/bleeding, thromboembolism, myocardial infarction, transient ischemic attack (TIA), pericarditis, heart block, pulmonary edema (respiratory insufficiency), and vagal nerve injury/gastroparesis.
|
Up to 3 months post-procedure
|
|
Percentage of Participants with Acute Effectiveness
Time Frame: Up to 3 months post-procedure
|
Percentage of participants with acute effectiveness will be reported.
Acute effectiveness is an electrical isolation of clinically relevant targeted pulmonary veins (PVs) which is evidenced by confirmation of entrance block, after adenosine/isoproterenol challenge, at the end of the index ablation procedure.
|
Up to 3 months post-procedure
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Percentage of Participants with Freedom from Documented (Symptomatic and Asymptomatic) Atrial Arrhythmia (Atrial Fibrillation [AF], Atrial Tachycardia [AT] or Atrial Flutter [AFL] of Unknown Origin) Episodes During the Effectiveness Evaluation Period
Time Frame: Within Day 91 to Day 365
|
Percentage of participants with freedom from documented (symptomatic and asymptomatic) atrial arrhythmia (AF, AT or AFL of unknown origin) episodes based on electrocardiographic data (more than equal to [>=]30 seconds on arrhythmia monitoring device) during the effectiveness evaluation period (Day 91 to Day 365) on or off antiarrhythmic therapy will be reported.
Acute procedural failure (that is, failure to achieve entrance block with the study device in any of the clinically relevant targeted PVs) will also be deemed a 12-month effectiveness failure.
|
Within Day 91 to Day 365
|
|
Percentage of PVs that are Targeted in the Index Ablation Procedure with Sustained Isolation at Day 75
Time Frame: Day 75
|
Percentage of PVs that are targeted in the index ablation procedure with sustained isolation, which is evidenced by electrical confirmation (through pacing for entrance block) of isolation at Day 75 post index ablation procedure will be reported.
|
Day 75
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Study Director: Biosense Webster, Inc. Clinical Trial, Biosense Webster, Inc.
Study record dates
Study Major Dates
Study Start (Estimated)
Study Start
Primary Completion (Estimated)
Primary Completion
Study Completion (Estimated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- BWI202304
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
IPD Plan Description
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.