TAVR for Aortic Regurgitation Under TTE Guidance
Radiation- and Contrast-Free Transcatheter Aortic Valve Replacement for Aortic Regurgitation Under Transthoracic Echocardiography Guidance
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Estimated)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Xiangbin Pan, MD
- Phone Number: +86 88396655
- Email: panxiangbin@fuwaihospital.org
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
- Older Adult
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Age ≥18 years.
- Severe native aortic regurgitation (AR) confirmed by echocardiography (per guideline-recommended multiparametric assessment).
- Indication for intervention, defined as symptomatic severe AR (e.g., NYHA class II-IV) or asymptomatic severe AR with evidence of LV decompensation (e.g., reduced LVEF and/or LV dilation per guideline thresholds).
- Deemed appropriate for transfemoral TAVR by a multidisciplinary Heart Team (e.g., elevated/prohibitive surgical risk or other clinical/anatomic factors favoring transcatheter therapy).
Exclusion Criteria:
- Active infective endocarditis or ongoing systemic infection/sepsis.
- Aortic pathology requiring open surgery, such as significant ascending aortic aneurysm/root disease above surgical thresholds, acute aortic syndrome, or other conditions where surgery is mandated.
- Annulus/landing-zone dimensions outside device range
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: TTE Guided TAVR
Participants assigned to this arm will undergo total transthoracic echocardiography (TTE)-guided transcatheter aortic valve replacement (TAVR) for treatment of significant native aortic regurgitation.
The procedure will be performed using a commercially available transcatheter heart valve and standard delivery system, with procedural planning and all key steps and immediate post-deployment evaluation-guided primarily by real-time TTE without routine fluoroscopy or iodinated contrast.
|
Intraprocedural TTE will be used to assess valve position and function, transvalvular gradients, paravalvular leak, and pericardial effusion, and to direct any adjunctive maneuvers (e.g., repositioning, post-dilation, or second-valve implantation) as clinically indicated.
Peri-procedural anticoagulation, anesthesia strategy, and post-procedure medical therapy will follow institutional standards.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
30-day Early Safety
Time Frame: 30-day follow-up
|
30-day Early Safety (composite, VARC-3): occurrence of any of the following within 30 days: All-cause mortality Disabling stroke Life-threatening or major bleeding Major vascular complication Acute kidney injury stage 2-3 (or new dialysis) Coronary obstruction requiring intervention Valve-related dysfunction or malposition requiring repeat intervention (e.g., second valve, surgical conversion) |
30-day follow-up
|
Collaborators and Investigators
Sponsor
Sponsor
Study record dates
Study Major Dates
Study Start (Estimated)
Study Start
Primary Completion (Estimated)
Primary Completion
Study Completion (Estimated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 20260302
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Aortic Regurgitation
-
NCT04047082UnknownHeart Valve Diseases | Aortic Valve Insufficiency | Paravalvular Aortic Regurgitation | Regurgitation, Aortic
-
NCT07605624Not yet recruitingAortic Stenosis | Mitral Regurgitation | Aortic Regurgitation | Tricuspid Regurgitation
-
NCT05117359CompletedCardiac Catheterization | Cardiac Valve Disease | Paravalvular Aortic Regurgitation | Paravalvular Mitral Regurgitation
-
NCT03578952TerminatedAortic Regurgitation | Aortic Valve Insufficiency | Regurgitation, Aortic Valve | Aortic Valve | Aortic Incompetence
-
NCT07197736RecruitingAortic Stenosis | Aortic Regurgitation | Valvular Heart Disease | Valve Disease, Aortic | Tricuspid Regurgitation (TR) | Mitral Regurgitation (MR)
-
NCT05438862Recruiting
-
NCT04489823Active, not recruitingParavalvular Aortic Regurgitation
-
NCT06835946RecruitingAortic Regurgitation Disease | Aortic Insufficiency
-
NCT04671758Unknown
Clinical Trials on TTE guided TAVR
-
NCT07453849Not yet recruitingAortic Regurgitation | Transcatheter Aortic Valve Replacement
-
NCT07278310RecruitingAortic Stenosis | Symptomatic Severe Native Aortic Stenosis
-
NCT05779787RecruitingAortic Valve Stenosis | Transcatheter Aortic Valve Replacement
-
NCT03827863UnknownARDS (Acute Respiratory Distress Syndrome) | Acute Cor Pulmonale
-
NCT07063147RecruitingCoronary Artery Disease | Stable Angina Pectoris | Major Adverse Cardiac Events | Invasive Coronary Angiography | Transthorcic Echocardiography
-
NCT01811914CompletedHemodynamic Instability During Anesthesia | High Risk Surgery
-
NCT00767013UnknownCoronary Disease | Aortic Valve Stenosis