Safety and Clinical Performance of the Next-Generation SAFESYNC Transcatheter Heart Valve in Patients With Severe Aortic Stenosis (SAFESYNC NG)

November 16, 2026 updated by: Braile Biomedica Ind. Com. e Repr. Ltda.

Evaluation of the Safety and Clinical Performance of the Next-Generation SAFESYNC Balloon-Expandable Transcatheter Heart Valve in Patients With Severe Aortic Stenosis: A Prospective, Multicenter, Single-Arm Pivotal Study

This pivotal, prospective, multicenter (Brazil, Chile and Argentina), single-arm study will evaluate the safety and clinical performance of the Inovare® Safesync Next-Generation bioprosthetic heart valve, implanted by transfemoral transcatheter aortic valve implantation (TAVI) with the B-Delivery System, in patients aged 70 years or older with severe aortic stenosis and an indication for TAVI, regardless of surgical risk. The study will enroll 210 participants.

Study Overview

Status

Not yet recruiting

Conditions

Intervention / Treatment

Study Type

Interventional

Enrollment (Estimated)

210

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Contact

  • Name: Clinical Research Department - Braile Biomédica
  • Phone Number: +5517 21367000
  • Email: pesquisa@braile.com.br

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

70 years and older (Older Adult)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Description

Inclusion Criteria:

Severe aortic valve stenosis diagnosed according to criteria established in current guidelines; Age ≥70 years, regardless of surgical risk; Indication for transcatheter aortic valve implantation (TAVI); Willing to participate and to sign the written informed consent form.

Exclusion Criteria:

Any condition considered a contraindication to implantation of a bioprosthetic heart valve (e.g., patient with an indication for a mechanical heart valve);

Known hypersensitivity or contraindication to any of the following that cannot be adequately managed with premedication:

  1. Aspirin, clopidogrel, or heparin (heparin-induced thrombocytopenia [HIT] or heparin-induced thrombocytopenia with thrombosis [HITTS]);
  2. Nitinol (titanium or nickel);
  3. Contrast media; Blood dyscrasias: leukopenia (white blood cell count <1,000/mm³), thrombocytopenia (platelet count <100,000 cells/mm³), history of coagulopathy, or hypercoagulable states; Active infection, including endocarditis; Cardiogenic shock manifested by low cardiac output, vasopressor dependence, or need for mechanical hemodynamic support; Recent stroke or transient ischemic attack (within 6 months); History of gastrointestinal bleeding or other bleeding that precludes anticoagulant or antiplatelet therapy; Estimated life expectancy of less than 5 years; Other medical, social, or psychological conditions that, in the investigator's opinion, prevent the patient from providing consent or adequately complying with the protocol; Pre-existing prosthetic heart valve in the aortic position (biological or mechanical); Concomitant severe mitral or tricuspid valve disease; Hypertrophic obstructive cardiomyopathy; Percutaneous coronary intervention performed within 72 hours prior to the study procedure; Femoral artery diameter <5.5 mm (for Safesync 20 to 24 mm), <6.0 mm (for Safesync 26 and 28 mm), or <6.5 mm (for Safesync 30 mm); High risk of annular rupture or significant residual paravalvular leak due to severe calcification of the aortic valve or left ventricular outflow tract; High risk of coronary obstruction (coronary ostial height <10 mm with narrow sinuses of Valsalva [SOV], defined as a mean SOV diameter <3 mm larger than the bioprosthesis size), as determined by computed tomography angiography; Left ventricular dysfunction with left ventricular ejection fraction (LVEF) ≤30%; Severe chronic kidney disease, defined as glomerular filtration rate <30 mL/min/1.73 m².

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Treatment
  • Allocation: N/A
  • Interventional Model: Single Group Assignment
  • Masking: None (Open Label)

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Experimental: INOVARE® SAFESYNC Next-Generation TAVI

Participants will undergo TAVI via transfemoral access using the INOVARE® SAFESYNC Next-Generation Bioprosthetic Heart Valve and the B-Delivery System.

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Device Success According to VARC-3 Criteria
Time Frame: 30 days after the procedure

Technical success; Absence of mortality; Absence of surgery or intervention related to the device or to major vascular, access-related, or cardiac structural complications; Intended valve performance, defined as mean transvalvular gradient <20 mmHg, peak velocity <3 m/s, Doppler velocity index ≥0.25, and less than moderate aortic regurgitation.

30 days after the procedure

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Percentage of Participants Achieving Technical Success According to VARC-3 Criteria
Time Frame: During the procedure

Defined as freedom from mortality; successful vascular access, delivery of the device, and retrieval of the delivery system; correct positioning of a single prosthetic heart valve in the intended anatomical location; and freedom from surgery or intervention related to the device or to a major vascular, access-related, or cardiac structural complication. Results will be reported as the number and percentage of participants achieving technical success.

During the procedure
Incidence and Severity of Paravalvular Leak
Time Frame: 30 days, 6 months, 12 months, and annually through 5 years

Paravalvular leak will be assessed by transthoracic echocardiography and classified according to severity. The number and percentage of participants with paravalvular leak in each severity category will be reported.

30 days, 6 months, 12 months, and annually through 5 years
Mean Transvalvular Aortic Pressure Gradient Assessed
Time Frame: 30 days, 6 months, 12 months, and annually through 5 years

Mean transvalvular aortic pressure gradient will be assessed by transthoracic echocardiography and reported in mmHg.

30 days, 6 months, 12 months, and annually through 5 years
Distribution of Participants by New York Heart Association Functional Class
Time Frame: 30 days, 6 months, 12 months, and annually through 5 years

Functional status will be assessed using the New York Heart Association (NYHA) Functional Classification. The classification ranges from Class I to Class IV, where Class I represents no limitation of physical activity and Class IV represents inability to perform physical activity without symptoms and/or symptoms at rest. Higher NYHA classes indicate worse functional status. Results will be reported as the number and percentage of participants in each NYHA functional class.

30 days, 6 months, 12 months, and annually through 5 years
Incidence of New Permanent Pacemaker Implantation
Time Frame: 30 days, 6 months, 12 months, and annually through 5 years

New permanent pacemaker implantation following the index transcatheter aortic valve implantation procedure will be assessed. Results will be reported as the number and percentage of participants who undergo new permanent pacemaker implantation.

30 days, 6 months, 12 months, and annually through 5 years
Incidence of All-Cause Mortality
Time Frame: 30 days, 6 months, 12 months, and annually through 5 years

All-cause mortality will be assessed throughout follow-up. Results will be reported as the number and percentage of participants who die from any cause.

30 days, 6 months, 12 months, and annually through 5 years
Incidence of Stroke
Time Frame: 30 days, 6 months, 12 months, and annually through 5 years

Stroke events will be assessed based on clinical neurological evaluation and classified according to Valve Academic Research Consortium 3 (VARC-3) definitions. Results will be reported as the number and percentage of participants experiencing stroke.

30 days, 6 months, 12 months, and annually through 5 years
Incidence of Bioprosthetic Valve-Related Reintervention
Time Frame: 30 days, 6 months, 12 months, and annually through 5 years

Bioprosthetic valve-related reintervention will be defined as any surgical or transcatheter intervention performed to treat dysfunction or failure of the implanted study valve. Results will be reported as the number and percentage of participants undergoing valve-related reintervention.

30 days, 6 months, 12 months, and annually through 5 years
Incidence of Bioprosthetic Valve Dysfunction According to VARC-3 Definitions
Time Frame: 30 days, 6 months, 12 months, and annually through 5 years

Bioprosthetic valve dysfunction will be assessed according to Valve Academic Research Consortium 3 (VARC-3) definitions. Bioprosthetic valve dysfunction includes structural valve deterioration, non-structural valve dysfunction, valve thrombosis, and endocarditis. Results will be reported as the number and percentage of participants meeting the criteria for bioprosthetic valve dysfunction and according to the corresponding category.

30 days, 6 months, 12 months, and annually through 5 years
Incidence of Bioprosthetic Valve Failure According to VARC-3 Definitions
Time Frame: 30 days, 6 months, 12 months, 24 months, 36 months, 48 months, and 60 months after the index procedure

Bioprosthetic valve failure will be assessed according to Valve Academic Research Consortium 3 (VARC-3) definitions. Results will be reported as the number and percentage of participants meeting the criteria for bioprosthetic valve failure.

30 days, 6 months, 12 months, 24 months, 36 months, 48 months, and 60 months after the index procedure

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Sponsor

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Estimated)

November 1, 2026

Primary Completion (Estimated)

July 1, 2027

Study Completion (Estimated)

June 1, 2032

Study Registration Dates

First Submitted

August 19, 2026

First Submitted That Met QC Criteria

September 3, 2026

First Posted (Actual)

September 8, 2026

Study Record Updates

Last Update Posted (Actual)

November 19, 2026

Last Update Submitted That Met QC Criteria

November 16, 2026

Last Verified

November 1, 2026

More Information

Terms related to this study

Other Study ID Numbers

  • SAFESYNC NG

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

NO

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.