Esta página se tradujo automáticamente y no se garantiza la precisión de la traducción. por favor refiérase a versión inglesa para un texto fuente.

Safety and Clinical Performance of the Next-Generation SAFESYNC Transcatheter Heart Valve in Patients With Severe Aortic Stenosis (SAFESYNC NG)

16 de noviembre de 2026 actualizado por: Braile Biomedica Ind. Com. e Repr. Ltda.

Evaluation of the Safety and Clinical Performance of the Next-Generation SAFESYNC Balloon-Expandable Transcatheter Heart Valve in Patients With Severe Aortic Stenosis: A Prospective, Multicenter, Single-Arm Pivotal Study

This pivotal, prospective, multicenter (Brazil, Chile and Argentina), single-arm study will evaluate the safety and clinical performance of the Inovare® Safesync Next-Generation bioprosthetic heart valve, implanted by transfemoral transcatheter aortic valve implantation (TAVI) with the B-Delivery System, in patients aged 70 years or older with severe aortic stenosis and an indication for TAVI, regardless of surgical risk. The study will enroll 210 participants.

Descripción general del estudio

Estado

Aún no reclutando

Condiciones

Intervención / Tratamiento

Tipo de estudio

Intervencionista

Inscripción (Estimado)

210

Fase

  • No aplica

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Estudio Contacto

  • Nombre: Clinical Research Department - Braile Biomédica
  • Número de teléfono: +5517 21367000
  • Correo electrónico: pesquisa@braile.com.br

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

70 años y mayores (Adulto Mayor)

Acepta Voluntarios Saludables

No

Géneros elegibles para el estudio

Todos

Descripción

Inclusion Criteria:

Severe aortic valve stenosis diagnosed according to criteria established in current guidelines; Age ≥70 years, regardless of surgical risk; Indication for transcatheter aortic valve implantation (TAVI); Willing to participate and to sign the written informed consent form.

Exclusion Criteria:

Any condition considered a contraindication to implantation of a bioprosthetic heart valve (e.g., patient with an indication for a mechanical heart valve);

Known hypersensitivity or contraindication to any of the following that cannot be adequately managed with premedication:

  1. Aspirin, clopidogrel, or heparin (heparin-induced thrombocytopenia [HIT] or heparin-induced thrombocytopenia with thrombosis [HITTS]);
  2. Nitinol (titanium or nickel);
  3. Contrast media; Blood dyscrasias: leukopenia (white blood cell count <1,000/mm³), thrombocytopenia (platelet count <100,000 cells/mm³), history of coagulopathy, or hypercoagulable states; Active infection, including endocarditis; Cardiogenic shock manifested by low cardiac output, vasopressor dependence, or need for mechanical hemodynamic support; Recent stroke or transient ischemic attack (within 6 months); History of gastrointestinal bleeding or other bleeding that precludes anticoagulant or antiplatelet therapy; Estimated life expectancy of less than 5 years; Other medical, social, or psychological conditions that, in the investigator's opinion, prevent the patient from providing consent or adequately complying with the protocol; Pre-existing prosthetic heart valve in the aortic position (biological or mechanical); Concomitant severe mitral or tricuspid valve disease; Hypertrophic obstructive cardiomyopathy; Percutaneous coronary intervention performed within 72 hours prior to the study procedure; Femoral artery diameter <5.5 mm (for Safesync 20 to 24 mm), <6.0 mm (for Safesync 26 and 28 mm), or <6.5 mm (for Safesync 30 mm); High risk of annular rupture or significant residual paravalvular leak due to severe calcification of the aortic valve or left ventricular outflow tract; High risk of coronary obstruction (coronary ostial height <10 mm with narrow sinuses of Valsalva [SOV], defined as a mean SOV diameter <3 mm larger than the bioprosthesis size), as determined by computed tomography angiography; Left ventricular dysfunction with left ventricular ejection fraction (LVEF) ≤30%; Severe chronic kidney disease, defined as glomerular filtration rate <30 mL/min/1.73 m².

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Propósito principal: Tratamiento
  • Asignación: N / A
  • Modelo Intervencionista: Asignación de un solo grupo
  • Enmascaramiento: Ninguno (etiqueta abierta)

Armas e Intervenciones

Grupo de participantes/brazo
Intervención / Tratamiento
Experimental: INOVARE® SAFESYNC Next-Generation TAVI

Participants will undergo TAVI via transfemoral access using the INOVARE® SAFESYNC Next-Generation Bioprosthetic Heart Valve and the B-Delivery System.

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Device Success According to VARC-3 Criteria
Periodo de tiempo: 30 days after the procedure

Technical success; Absence of mortality; Absence of surgery or intervention related to the device or to major vascular, access-related, or cardiac structural complications; Intended valve performance, defined as mean transvalvular gradient <20 mmHg, peak velocity <3 m/s, Doppler velocity index ≥0.25, and less than moderate aortic regurgitation.

30 days after the procedure

Medidas de resultado secundarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Percentage of Participants Achieving Technical Success According to VARC-3 Criteria
Periodo de tiempo: During the procedure

Defined as freedom from mortality; successful vascular access, delivery of the device, and retrieval of the delivery system; correct positioning of a single prosthetic heart valve in the intended anatomical location; and freedom from surgery or intervention related to the device or to a major vascular, access-related, or cardiac structural complication. Results will be reported as the number and percentage of participants achieving technical success.

During the procedure
Incidence and Severity of Paravalvular Leak
Periodo de tiempo: 30 days, 6 months, 12 months, and annually through 5 years

Paravalvular leak will be assessed by transthoracic echocardiography and classified according to severity. The number and percentage of participants with paravalvular leak in each severity category will be reported.

30 days, 6 months, 12 months, and annually through 5 years
Mean Transvalvular Aortic Pressure Gradient Assessed
Periodo de tiempo: 30 days, 6 months, 12 months, and annually through 5 years

Mean transvalvular aortic pressure gradient will be assessed by transthoracic echocardiography and reported in mmHg.

30 days, 6 months, 12 months, and annually through 5 years
Distribution of Participants by New York Heart Association Functional Class
Periodo de tiempo: 30 days, 6 months, 12 months, and annually through 5 years

Functional status will be assessed using the New York Heart Association (NYHA) Functional Classification. The classification ranges from Class I to Class IV, where Class I represents no limitation of physical activity and Class IV represents inability to perform physical activity without symptoms and/or symptoms at rest. Higher NYHA classes indicate worse functional status. Results will be reported as the number and percentage of participants in each NYHA functional class.

30 days, 6 months, 12 months, and annually through 5 years
Incidence of New Permanent Pacemaker Implantation
Periodo de tiempo: 30 days, 6 months, 12 months, and annually through 5 years

New permanent pacemaker implantation following the index transcatheter aortic valve implantation procedure will be assessed. Results will be reported as the number and percentage of participants who undergo new permanent pacemaker implantation.

30 days, 6 months, 12 months, and annually through 5 years
Incidence of All-Cause Mortality
Periodo de tiempo: 30 days, 6 months, 12 months, and annually through 5 years

All-cause mortality will be assessed throughout follow-up. Results will be reported as the number and percentage of participants who die from any cause.

30 days, 6 months, 12 months, and annually through 5 years
Incidence of Stroke
Periodo de tiempo: 30 days, 6 months, 12 months, and annually through 5 years

Stroke events will be assessed based on clinical neurological evaluation and classified according to Valve Academic Research Consortium 3 (VARC-3) definitions. Results will be reported as the number and percentage of participants experiencing stroke.

30 days, 6 months, 12 months, and annually through 5 years
Incidence of Bioprosthetic Valve-Related Reintervention
Periodo de tiempo: 30 days, 6 months, 12 months, and annually through 5 years

Bioprosthetic valve-related reintervention will be defined as any surgical or transcatheter intervention performed to treat dysfunction or failure of the implanted study valve. Results will be reported as the number and percentage of participants undergoing valve-related reintervention.

30 days, 6 months, 12 months, and annually through 5 years
Incidence of Bioprosthetic Valve Dysfunction According to VARC-3 Definitions
Periodo de tiempo: 30 days, 6 months, 12 months, and annually through 5 years

Bioprosthetic valve dysfunction will be assessed according to Valve Academic Research Consortium 3 (VARC-3) definitions. Bioprosthetic valve dysfunction includes structural valve deterioration, non-structural valve dysfunction, valve thrombosis, and endocarditis. Results will be reported as the number and percentage of participants meeting the criteria for bioprosthetic valve dysfunction and according to the corresponding category.

30 days, 6 months, 12 months, and annually through 5 years
Incidence of Bioprosthetic Valve Failure According to VARC-3 Definitions
Periodo de tiempo: 30 days, 6 months, 12 months, 24 months, 36 months, 48 months, and 60 months after the index procedure

Bioprosthetic valve failure will be assessed according to Valve Academic Research Consortium 3 (VARC-3) definitions. Results will be reported as the number and percentage of participants meeting the criteria for bioprosthetic valve failure.

30 days, 6 months, 12 months, 24 months, 36 months, 48 months, and 60 months after the index procedure

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Patrocinador

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio (Estimado)

1 de noviembre de 2026

Finalización primaria (Estimado)

1 de julio de 2027

Finalización del estudio (Estimado)

1 de junio de 2032

Fechas de registro del estudio

Enviado por primera vez

19 de agosto de 2026

Primero enviado que cumplió con los criterios de control de calidad

3 de septiembre de 2026

Publicado por primera vez (Actual)

8 de septiembre de 2026

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

19 de noviembre de 2026

Última actualización enviada que cumplió con los criterios de control de calidad

16 de noviembre de 2026

Última verificación

1 de noviembre de 2026

Más información

Términos relacionados con este estudio

Otros números de identificación del estudio

  • SAFESYNC NG

Plan de datos de participantes individuales (IPD)

¿Planea compartir datos de participantes individuales (IPD)?

NO

Información sobre medicamentos y dispositivos, documentos del estudio

Estudia un producto farmacéutico regulado por la FDA de EE. UU.

No

Estudia un producto de dispositivo regulado por la FDA de EE. UU.

No

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .