EXecutive Registry: Evaluating XIENCE V® in a Multi Vessel Disease (EXecutive)

December 20, 2012 updated by: Abbott Medical Devices

EXecutive Registry: XIENCE V® Everolimus Eluting Coronary Stent System (XIENCE V® EECSS) in the Treatment of the Specific Setting of Patients With Multi-vessel Coronary Artery Disease.

The purpose of this two part study is the assessment of the performance of the XIENCE V® Everolimus Eluting Coronary Stent System (XIENCE V® EECSS) in the treatment of the specific setting of patients with Multi-Vessel Coronary Artery Disease (MVD).

Study Overview

Detailed Description

This is a clinical evaluation of the XIENCE V® everolimus eluting coronary stent system as a revascularization treatment of patients with multi-vessel coronary artery disease (MVD-CAD).

The sutdy is composed of two parts:

A Randomized Controlled Trial, outlined in a separate posting and the registry portion of this study, which is as follows:

-A prospective controlled registry to analyze the clinical efficacy and safety at mid and long-term follow-up in patients with MVD treated with the XIENCE V® Everolimus Eluting Coronary Stent System (XIENCE V® EECSS).

Study Type

Observational

Enrollment (Actual)

400

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

      • Agrigento, Italy
        • A.O. San Giovanni di Dio
      • Bologna, Italy
        • Ospedale Maggiore Bologna
      • Bologna, Italy
        • Policlinico S. Orsola - Malpighi
      • Catania, Italy
        • A.O. Cannizzaro
      • Catania, Italy
        • A.O. Universitaria Vittorio Emanuele - Ferrarotto - S. Bambino
      • Catanzaro, Italy
        • A.O. Università Mater Domini c/o Campus Università Magna Grecia
      • Foggia, Italy
        • A.O. Universitaria OO.RR Foggia
      • Genova, Italy
        • E.O. Ospedali Galliera
      • Mantova, Italy
        • A.O. Carlo Poma
      • Milano, Italy
        • Centro Cardiologico Monzino
      • Napoli, Italy
        • Ospedale Loreto Mare
      • Roma, Italy
        • A. O. Sant'Andrea
      • Roma, Italy
        • Ospedale Generale Madre Vannini
      • Roma, Italy
        • Ospedale Sandro Pertini
      • Torino, Italy
        • Ospedale Maria Vittoria
      • Torino, Italy
        • A.S.O. Molinette San Giovanni Battista di Torino
      • Torino, Italy
        • P.O. San Giovanni Bosco
      • Torino, Italy
        • San Giovanni Battista - Ospedale Molinette
      • Torrette Di Ancona, Italy
        • A.O. Universitaria - Ospedale Riuniti Umberto I - G.M. Lancisi - G. Salesi
      • Verona, Italy, 37142
        • Ospedale Civile Maggiore - Università di Verona
      • Vicenza, Italy
        • Ospedale Civile
      • Vigevano, Italy
        • Ospedale Civile di Vigevano
      • Voghera, Italy
        • A.O. Della Provincia di Pavia

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years and older (Adult, Older Adult)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Sampling Method

Non-Probability Sample

Study Population

Patients with Multi-Vessel Coronary Artery Disease (MVD) treated with the XIENCE V® Everolimus Eluting Coronary Stent System (XIENCE V® EECSS).

Description

Inclusion Criteria:

  1. Patient must be at least 18 years of age
  2. Patient is able to verbally confirm understanding of risks, benefits and treatment alternatives of receiving the XIENCE V® EECSS and he/she or his/her legally authorized representative provides written informed consent prior to any study related procedure, as approved by the appropriate Medical Ethics Committee of the respective clinical site
  3. Patient has been diagnosed a MVD, as documented by coronary angiography, i.e. presenting a severe stenosis (>50%) amenable to PCI in at least 2 major epicardial vessels or their principal bifurcation branches (diagonal or obtuse marginal)
  4. Patient must have evidence of myocardial ischemia (e.g., stable or unstable angina, silent ischemia, positive functional study or a reversible change in the electrocardiogram -ECG- consistent with ischemia)
  5. Patient must be an acceptable candidate for coronary artery bypass graft (CABG) surgery
  6. Patient must agree to undergo all protocol-required follow-up examinations.

Angiographic Inclusion Criteria

  1. Patients may receive up to 4 planned XIENCE V® EECSS stents, depending on the number of vessels treated and their respective lesion length. When multiple lesions are present in one or more main coronary branches, complete revascularization should be attempted with the implantation of a maximum of 4 planned stents
  2. Target lesions must be de novo lesions (no prior stent implant, no prior brachytherapy)
  3. Target vessel reference diameter must be between 2.5 mm and 4.0 mm by visual estimate
  4. Target lesion < or = 28 mm in length by visual estimation
  5. Target lesions must be in a major artery or its principal branches (diagonal or obtuse marginal) with a visually estimated stenosis of > or = 50%
  6. Two lesions in a single main coronary artery or its branches do not constitute a MVD situation, therefore this type of patient must not be enrolled

Exclusion Criteria:

  1. Patient has had a known diagnosis of acute myocardial infarction (AMI) within 72 hours preceding the index procedure (non-procedural/spontaneous MI, CK-MB > or = to 2 times upper limit of normal) and CK and CK-MB have not returned within normal limits at the time of procedure
  2. Patient has current unstable arrhythmias
  3. Patient has a known left ventricular ejection fraction (LVEF) <30%
  4. Patient has received a heart transplant or any other organ transplant or is on a waiting list for any organ transplant
  5. Patient is receiving or scheduled to receive chemotherapy or radiation therapy within 30 days prior to or after the procedure.
  6. Patient is receiving immunosuppression therapy or has known immunosuppressive or autoimmune disease (e.g. human immunodeficiency virus, systemic lupus erythematosus etc.)
  7. Patient is receiving chronic anticoagulation therapy (e.g. coumadin)
  8. Patient has a known hypersensitivity or contraindication to aspirin, paclitaxel, either heparin or bivalirudin, clopidogrel or ticlopidine, everolimus, cobalt, chromium, nickel, tungsten, acrylic and fluoro polymers or contrast sensitivity that cannot be adequately pre-medicated
  9. Elective surgery is planned within the first 9 months (+/- 14 days) after the procedure that will require discontinuing either aspirin or clopidogrel
  10. Patient has a platelet count <100,000 cells/mm3 or >700,000 cells/mm3, a WBC of <3,000 cells/mm3, or documented or suspected liver disease (including laboratory evidence of hepatitis)
  11. Patient has known renal insufficiency (e.g., serum creatinine level of more than 2.5 mg/dl, patient on dialysis)
  12. Patient has a history of bleeding diathesis or coagulopathy or will refuse blood transfusions
  13. Patient has had a cerebrovascular accident (CVA) or transient ischemic neurological attack (TIA) within the past six months
  14. Patient has had a significant GI or urinary bleed within the past six months
  15. Patient has other medical illness (e.g., cancer or congestive heart failure) or known history of substance abuse (alcohol, cocaine, heroin etc.) that may cause non-compliance with the protocol, confound the data interpretation or is associated with a limited life expectancy (i.e. less than one year)
  16. Patient is already participating in another investigational use device or drug study or has completed the follow-up phase of another study within the last 30 days.

Angiographic Exclusion Criteria

  1. Target lesion meets any of the following criteria:

    • Left main location
    • Located within an arterial or saphenous vein graft or distal to a diseased arterial or saphenous vein graft (defined as vessel irregularity per angiogram and >20% stenosed lesion by visual estimation)
    • Heavy calcification
  2. The patient may need more than 4 planned stents. Bailout stents are allowed but must be of the same type as randomization stent.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Observational Models: Cohort
  • Time Perspectives: Prospective

Cohorts and Interventions

Group / Cohort
Intervention / Treatment
EXecutive Registry
A prospective controlled registry to analyze the clinical efficacy and safety at mid and long-term follow-up in patients with MVD treated with the XIENCE V® Everolimus Eluting Coronary Stent System (XIENCE V® EECSS).
Coronary artery placement of a drug-eluting stent (XIENCE V® EECSS)

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Composite endpoint of all Death, MI (Q-wave and non Q-wave), and ischemia-driven Target Vessel Revascularization (TVR) .
Time Frame: 12 months
Composite endpoints are endpoints made up of a range of statistical parameters.
12 months

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Adjudicated stent thrombosis
Time Frame: 30 days
30 days
Revascularizations (TLR/TVR/any revascularization)
Time Frame: 30 days
30 days
Composite endpoint of cardiac death, MI (Q-wave and non Q-wave), and ischemia-driven TLR.
Time Frame: 30 days
30 days
Composite endpoint of all death, MI (Q-wave and non Q-wave), and TVR.
Time Frame: 30 days
30 days
Device success
Time Frame: At time of index procedure
Achievement of a final residual in-stent diameter stenosis of < 30% (visual assessment) using the assigned device only.
At time of index procedure
Lesion success
Time Frame: At time of index procedure
Attainment of < 30% residual in-stent stenosis (by visual assessment) using any percutaneous method.
At time of index procedure
Procedural success defined as: residual in-stent %DS of < 30% using a percutaneous method, without cardiac death, Q-wave MI, non Q-wave MI, or repeat revasc of the target during hospitalization.
Time Frame: At time of index procedure
At time of index procedure
Adjudicated stent thrombosis
Time Frame: 1 year
1 year
Adjudicated stent thrombosis
Time Frame: 2 years
2 years
Adjudicated stent thrombosis
Time Frame: at 3 years
at 3 years
Revascularizations (TLR/TVR/any revascularization)
Time Frame: 1 year
1 year
Revascularizations (TLR/TVR/any revascularization)
Time Frame: 2 years
2 years
Revascularizations (TLR/TVR/any revascularization)
Time Frame: 3 years
3 years
Composite endpoint of cardiac death, MI (Q-wave and non Q-wave), and ischemia-driven TLR.
Time Frame: 1 years
1 years
Composite endpoint of cardiac death, MI (Q-wave and non Q-wave), and ischemia-driven TLR.
Time Frame: 2 years
2 years
Composite endpoint of cardiac death, MI (Q-wave and non Q-wave), and ischemia-driven TLR.
Time Frame: 3 years
3 years
Composite endpoint of all death, MI (Q-wave and non Q-wave), and TVR.
Time Frame: 2 years
2 years
Composite endpoint of all death, MI (Q-wave and non Q-wave), and TVR.
Time Frame: 3 years
3 years

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Investigators

  • Principal Investigator: Corrado Vassanelli, MD, Ospedale Civile Maggiore - Università di Verona
  • Principal Investigator: Flavio Ribichini, MD, Ospedale Civile Maggiore - Università di Verona

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start

September 1, 2007

Primary Completion (Actual)

October 1, 2010

Study Completion (Actual)

June 1, 2011

Study Registration Dates

First Submitted

March 3, 2011

First Submitted That Met QC Criteria

March 7, 2011

First Posted (Estimate)

March 8, 2011

Study Record Updates

Last Update Posted (Estimate)

December 21, 2012

Last Update Submitted That Met QC Criteria

December 20, 2012

Last Verified

December 1, 2012

More Information

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Coronary Artery Disease

Clinical Trials on Coronary artery placement of a drug-eluting stent