The Effect of Fluids Flushed in Pediatric Cardiac Catheterization Procedures on Lung Ultrasound Score

March 16, 2020 updated by: Mai Madkour, Cairo University

The Effect of Fluids Flushed in Pediatric Cardiac Catheterization Procedures on Lung Ultrasound Score: A Prospective Observational Study

Therapeutic catheterizations substituted many traditional surgical procedures with the advance of transcatheter techniques.

Pediatric patients are more liable to fluid overload due to their smaller weights compared to adults and the risk increases in pediatrics with congenital heart diseases due to lower tolerability and reserve capacity and some of them may already have a degree of heart failure. Fluid overload increases the incidence of morbidity and mortality in such patients.

The aim of our study is to observe the amount of fluids needed for flushing during pediatric cardiac catheterization (in ml/kg) and asses its effect on total lung water and PaO2/FiO2, aiming to develop a useful protocol for the amount of fluids used.

Study Overview

Status

Unknown

Detailed Description

.Objectives: The objective of this study is to assess lung water by comparing the calculated values of lung score by ultrasound, PaO2/FiO2 ratio and PaCO2 obtained from arterial blood gases' samples before and after the procedures.

. Study Design:

  • A prospective observational study. Study Method
  • Population of study & disease condition Children from 1 month to 6 years undergoing cardiac catheterization procedures..
  • Study setting:

This study will be conducted at Abo El Reesh Paediatric Hospital, Faculty of Medicine, Cairo University.

- Methodology in details: General anesthesia After interviewing and taking proper history from the parents, examining the patients, checking all routine investigations, informed consent will be taken after discussion with them.

Standard monitoris will be applied to all patients (electrocardiography, pulse oximetry, end-tidal Carbon dioxide CO2, non-invasive arterial blood pressure). All patients will be induced with inhalational induction using 4% sevoflurane in 100% oxygen followed by placement of a peripheral intravenous cannula. Oral endotracheal intubation will be facilitated by IV administration of fentanyl (1-2mic/kg) and atracurium (0.5mg/kg).

Mechanical ventilation will be maintained with an inspired oxygen fraction (FiO2) of 50%, a positive end expiratory pressure (PEEP) of 5 cmH2O, I:E ratio of 1:2 and a peak inspiratory pressure (PIP) will be set to deliver a tidal volume of 5-8 ml/kg and respiratory rate from 15 to 35 cycle per minute according to the end tidal carbon dioxide CO2.

After maintenance of anesthesia and before the procedure lung ultrasound examination will be performed using curved transducer with low frequency (2-5MHz) and will be assessed for the presence of B lines. Arterial blood gases will be aspirated. After the end of the procedure and before awakening the patient both arterial blood gases and lung ultrasound examination will be repeated provided that no complications occurred such as spell or hypertensive crisis.

Maintenance requirements of intravenous fluids will be given by crystalloid solution (lactated ringer) calculated by the "4:2:1 rule": 4 ml/kg/h for the first 10 kg of weight, 2 ml/kg/h for the second 10 kg, and 1 ml/kg/h for each remaining kilograms, in addition preoperative fluid deficits will be replaced calculated by multiplying maintenance requirement per hour by number of hours infant has not received oral or intravenous fluids prior to surgery in aliquots of 50% in the first hour and 25% in second and third hours.

The operators will insert intra-vascular sheathes and catheters that will frequently need to be flushed with heparinized solutions to keep them patent. The amount of the infused solutions will be calculated. This amount will be correlated to the lung ultrasound score.

Lung ultrasound The lung ultrasound score (LUS) is obtained by scanning 12-rib interspaces where each hemithorax divided into 6 areas. Each scanning site yields a score denoting the extent of interstitial pulmonary oedema.

Zero is defined as a complete absence of B-lines in the investigated area. When B-lines are few in the scanning site, they can be easily counted. When they are more numerous, they tend to be confluent and it is less easy to clearly enumerate them. To obtain a semi quantification of the sign, we consider the percentage of scanning site obtained by B-lines (i.e, the percentage of the white screen compared to the black screen below the pleural line) and then divided by 10 (i.e, 30% corresponds to about 3 B-lines, 70% corresponds to about 7 B-lines , and so on). This yields lung score in each site.

Scoring system of lung ultrasound:

Four ultrasound aeration patterns were defined as:

Normal aeration (N): Line sliding sign associated with respiratory movement. Moderate loss of lung aeration (B1 lines) : A clear number of multiple visible B-lines with horizontal spacing between adjacent B lines ≤ 7 mm.

Severe loss of lung aeration (B2 lines): Multiple B lines fused together that were difficult to count with horizontal spacing between adjacent B lines ≤ 3 mm.

White lung,pulmonary consolidation (C): Hyperechoic lung tissue, accompanied by dynamic air bronchogram.

LUS will be determined based on four lung ultrasonographs: N = 0, B1 = 1, B2 = 2 , and C = 3. All patients will undergo a lung ultrasound, and each of the 12 lung areas will be examined. The final LUS of the patient will be the sum of each regional ultrasound score (ranging from 0 to 36).

  • Intervention:

Diagnostic intervention: After maintenance of anesthesia and before the procedure lung ultrasound examination will be performed and will be assessed for the presence of B lines. Arterial blood gases will be aspirated. After the end of the procedure and before awakening the patient both arterial blood gases and lung ultrasound examination will be repeated provided that no complications occurred such as spell or hypertensive crisis.

- Potential risks: No additional risks to the study and any risk is related to the surgical procedure itself.

Statistical analysis The Statistical Package of Social Science software program (SPSS), version 21 (Chicago, USA) will be used for all statistical comparisons. Continuous quantitative normally distributed data will be expressed as means and standard deviations (SD), while non-normally distributed data will be expressed as median and range. Qualitative nominal data will be expressed by percentage.

After testing for normality, continuous variables will be compared using t-test or Mann-Whitney U test as appropriate. Categorical variables will be compared using Chi- squared test or Fisher's exact test as appropriate. Changes over time will be compared using ANOVA for repeated measures with Bonferroni correction. Correlation between amount of fluids and lung score will be conducted by pearson's or spearman's methods according to the normality of data. A p-value <0.05 will be considered statistically significant.

Study Type

Observational

Enrollment (Anticipated)

43

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

    • الجيزة
      • Giza, الجيزة, Egypt, 12555
        • Cairo University Pediatric Hospitals

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

1 month to 6 years (Child)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Sampling Method

Probability Sample

Study Population

Children from 1 month to 6 years undergoing cardiac catheterization procedures..

This study will be conducted at Abo El Reesh Paediatric Hospital, Faculty of Medicine

Description

Inclusion Criteria:

  • Pediatric patients undergoing diagnostic cardiac catheterization procedures.

Exclusion Criteria:

  • Age <1 month and >6 years.
  • Preoperative mechanical ventilation.
  • Heart failure
  • Patients with oligemic lung diseases.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Change between lung ultrasound score before and after fluids flushed
Time Frame: at the start of the procedure of cardiac catherization and immediately after the end of the procedure
heparinized fluids are flushed throughout catheterization through venous and arterial sheathes , ultrasound score will be measured before and after the flushing
at the start of the procedure of cardiac catherization and immediately after the end of the procedure

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
. Change between PaO2/FiO2 ratio
Time Frame: immediately before and immediately after the procedure.
change in ratio between arterial Oxygen tension and Fraction of inspired Oxygen
immediately before and immediately after the procedure.
Correlation between lung score and PaO2/FiO2 ratio
Time Frame: immediately before and immediately after the procedure.
statistically measuring if there is a relation between lung ultrasound score and PaO2/FiO2 ratio
immediately before and immediately after the procedure.

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

March 1, 2020

Primary Completion (Anticipated)

October 15, 2020

Study Completion (Anticipated)

March 15, 2021

Study Registration Dates

First Submitted

March 11, 2020

First Submitted That Met QC Criteria

March 16, 2020

First Posted (Actual)

March 17, 2020

Study Record Updates

Last Update Posted (Actual)

March 17, 2020

Last Update Submitted That Met QC Criteria

March 16, 2020

Last Verified

March 1, 2020

More Information

Terms related to this study

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

UNDECIDED

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Congenital Heart Disease

3