Wearable Evaluation of Ambulatory Readings for Blood Pressure (WEAR-BP)
Study Overview
Status
Detailed Description
The investigators will recruit community-dwelling participants to wear novel cuffless BP monitoring devices for comparison with a Spacelabs ABPM device throughout a 24-hour period. The identification of accurate cuffless BP technologies would greatly improve access to ABPM and allow for BP measurements at times when the use of cuff-based devices are not feasible. Knowledge from this project will inform subsequent research protocols among adults and under-represented groups.
Up to 250 participants (at least 100) will be involved in this study each wearing up to 7 devices (6 BP devices and 1 activity monitor). The assignment of devices will be randomized by day and by the arm or wrist on which they are worn. During the first visit, participants will provide their consent and be randomly fitted with 3 BP devices; either the Spacelabs ABPM device or the ABPMpro device, the Aktiia wristband BP monitor, and one of two other cuff-based wrist BP monitors, along with an activity monitor to track body positions. These devices will be worn continuously for at least 24-hours, including overnight, before being returned. On the following day, for Visit 2, participants will be fitted with a different set of 3 BP devices; the ABPMpro device or Spacelabs ABPM device, the Aktiia wristband BP device (on the opposite wrist from the previous day), and the final cuff-based wristband BP device. Additionally, participants will wear an ambulatory BP device as a patch on the chest. These devices will also be worn for at least 24 hours. This study will enable characterization of the feasibility, practicality, and effectiveness of the measurements and the devices' accuracy and precision.
Study Type
Enrollment (Estimated)
Phase
- Not Applicable
Contacts and Locations
Study Contact
- Name: Stephen P. Juraschek, MD, PhD
- Phone Number: 617-754-1416
- Email: sjurasch@bidmc.harvard.edu
Study Contact Backup
- Name: Fredrick Larbi Kwapong, MD, MPH
- Phone Number: 781-975-4920
- Email: flarbikw@bidmc.harvard.edu
Study Locations
-
-
Massachusetts
-
Boston, Massachusetts, United States, 02215
- Recruiting
- Beth Israel Deaconess Medical Center
-
Contact:
- Stephen Juraschek, MD, PhD
- Phone Number: 6177541416
- Email: sjurasch@bidmc.harvard.edu
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
- Older Adult
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Age 18 to 100 years
- All neighborhoods in Boston area
- Be able to walk with two limbs and have two arms
- Willing and able to complete required measurement procedures
- Able to provide informed consent
Exclusion Criteria:
- Failure to receive informed consent
- Arm circumference of more than 50cm
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Other
- Allocation: Randomized
- Interventional Model: Crossover Assignment
- Masking: None (Open Label)
Arms and Interventions
Participant Group / Arm |
Intervention / Treatment |
|---|---|
|
Experimental: Cuff-based ambulatory blood pressure monitor sequence
Participants will be randomized 1:1 to wear (A) the Spacelabs ambulatory blood pressure monitor on the first day and ABPMPro ambulatory blood pressure monitor on the second day or (B) ABPMPro ambulatory blood pressure monitor on the first day then Spacelabs ambulatory blood pressure monitor on the second day.
|
This is an upper arm, cuff-based intermittent ambulatory BP device.
This device has an internal activity and body position sensor which gathers information about sleep-wake estimation.
This is an upper arm cuff-based device with tubing for continuous ambulatory BP monitoring with a unique activity sensor that correlate with patient movement activity with blood pressure changes.
|
|
Experimental: Left versus right upper limb
Participants will be randomized to wear the Aktiia cuffless blood pressure device on either the left upper limb versus the right upper limb on the first day.
On the second day, the Aktiia blood pressure device will be switched to the other arm which did not get randomized on the first day.
Another wristband (LiveMetric versus Bpro) will be worn on the contralateral arm.
|
This is a wrist cuff-based device which uses an optical sensor (photoplethysmography sensor) to gather data from the arteries under the skin surface.
Aktiia has an upper arm cuff device which is used for calibration once every month to provide a baseline blood pressure reading.
This is a wrist cuff-based applanation tonometry continuous ambulatory BP device.
This device has automatic self-calibration and comes in various sizes.
This is a wrist cuff-based wireless oscillometric, continuous ambulatory BP device.
It has applanation tonometry at the wrist with Pulse wave analysis.
This device needs calibration with a brachial cuff BP measurement.
|
|
Experimental: Wristband sequence (first day versus second day)
Participants will be randomized 1:1 to wear (A) the LiveMetric wristband on the first day and Bpro wristband on the second day or (B) Bpro wristband on the first day then LiveMetric wristband on the second day.
The arm side (i.e., right or left) will be determined by the Aktiia cuffless blood pressure device randomization on the first day.
For the second day, the Aktiia cuffless blood pressure device will be worn on the arm opposite the first day with the other device (LiveMetric versus Bpro) worn on the contralateral arm.
|
This is a wrist cuff-based device which uses an optical sensor (photoplethysmography sensor) to gather data from the arteries under the skin surface.
Aktiia has an upper arm cuff device which is used for calibration once every month to provide a baseline blood pressure reading.
This is a wrist cuff-based applanation tonometry continuous ambulatory BP device.
This device has automatic self-calibration and comes in various sizes.
This is a wrist cuff-based wireless oscillometric, continuous ambulatory BP device.
It has applanation tonometry at the wrist with Pulse wave analysis.
This device needs calibration with a brachial cuff BP measurement.
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Systolic Blood Pressure
Time Frame: 24 - 48 hours
|
Measured from all 5 randomized devices
|
24 - 48 hours
|
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Diastolic Blood Pressure
Time Frame: 24 - 48 hours
|
Measured from all 5 randomized devices
|
24 - 48 hours
|
|
Heart Rate
Time Frame: 24 - 48 hours
|
Measured from all 5 randomized devices
|
24 - 48 hours
|
|
ActivPaL device (Physical activity monitor)
Time Frame: 24 - 48 hours
|
Physical activity intensity and type of activity will be characterized throughout the 48hr wear period.
While the investigators are interested in the impact of devices on activity, the investigators are also interested in the relationship between activities and blood pressure.
|
24 - 48 hours
|
Other Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Systolic blood pressure from the Biobeat device (Chest Patch Blood Pressure device)
Time Frame: 24 hours
|
This is a continuous ambulatory BP device which is worn as a patch on the chest.
This device needs calibration with a brachial cuff BP measurement.
This will be typically worn on day 2.
This is not a randomized assessment.
|
24 hours
|
Collaborators and Investigators
Publications and helpful links
Helpful Links
Study record dates
Study Major Dates
Study Start (Actual)
Primary Completion (Estimated)
Study Completion (Estimated)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Actual)
Study Record Updates
Last Update Posted (Actual)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
- 2024P000441
- 5R01HL158622 (U.S. NIH Grant/Contract)
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
IPD Plan Description
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Normal Blood Pressure
-
Indena S.p.ARecruitingHigh-normal Blood PressureItaly
-
GE HealthcareTerminatedBlood Pressure (Low, Normal, High)United States
-
Umeå UniversityCompletedIdiopathic Normal Pressure Hydrocephalus
-
Göteborg UniversityDepartment of Neurological Surgery, Sahlgrenska University Hospital; Hydrocephalus... and other collaboratorsNot yet recruitingNormal Pressure Hydrocephalus | Normal Pressure Hydrocephalus Patients
-
University Hospital, Basel, SwitzerlandRecruitingIdiopathic Normal Pressure Hydrocephalus (INPH)Switzerland
-
DeepsonbioRecruitingIdiopathic Normal Pressure Hydrocephalus (iNPH)Korea, Republic of
-
Uppsala University HospitalUppsala University; Swedish Society for Medical ResearchCompletedIdiopathic Normal Pressure Hydrocephalus (INPH)Sweden
-
Johns Hopkins UniversityUniversity of Utah; Integra LifeSciences CorporationCompletedIdiopathic Normal Pressure Hydrocephalus (INPH)United States, Canada, Sweden
-
Mayo ClinicTerminatedNormal Pressure Hydrocephalus PatientsUnited States
-
Umeå UniversityCompleted