Novel Thin Bronchoscope Versus Ultrathin Bronchoscope for the Diagnosis of Peripheral Pulmonary Nodules

August 14, 2025 updated by: Jiayuan Sun, Shanghai Chest Hospital

Novel Thin Bronchoscope Versus Ultrathin Bronchoscope for the Diagnosis of Peripheral Pulmonary Nodules: A Multicenter, Randomised Trial

This is a prospective, randomised, non-inferior, multicenter study in consecutive patients with solid or sub-solid PPLs 8 to 30 mm in diameter.The subjects will be randomly assigned in a 1:1:1 ratio to the 3.0mm outer diameter/1.7mm forceps channel ultrathin bronchoscope group (UTB-VBN-EBUS group), the 3.3mm outer diameter/2.0mm forceps channel novel thin bronchoscope combined with guide sheath group (TB1-VBN-EBUS-GS group), and the 4.2mm outer diameter/2.8mm forceps channel novel thin bronchoscope combined with guide sheath group (TB2-VBN-EBUS-GS group). All procedures will be performed using UTB or TB with the guidance of virtual bronchoscopic navigation (VBN) combined with radial endobronchial ultrasound (rEBUS), but without fluoroscopy. A small forceps will be used in UTB-VBN-EBUS group and TB1-VBN-EBUS-GS group, while a standard forceps will be used in TB2-VBN-EBUS-GS group. Primary endpoint is the diagnostic yield.

Study Overview

Detailed Description

This is a prospective, randomised, non-inferior, multicenter study. The inclusion criteria are patients whose chest imaging shows suspiciously malignant peripheral lung nodules (the nodules are surrounded by lung tissue and are located below the segmental bronchus), and the diameter of the lesion is between 8mm and 30mm. The subjects will be randomly assigned in a 1:1:1 ratio to the 3.0mm outer diameter/1.7mm forceps channel ultrathin bronchoscope group (UTB-VBN-EBUS group), the 3.3mm outer diameter/2.0mm forceps channel novel thin bronchoscope combined with guide sheath group (TB1-VBN-EBUS-GS group), and the 4.2mm outer diameter/2.8mm forceps channel novel thin bronchoscope combined with guide sheath group (TB2-VBN-EBUS-GS group). All procedures were performed using UTB or TB with the guidance of virtual bronchoscopic navigation (VBN) combined with radial endobronchial ultrasound (rEBUS), but without fluoroscopy. A small forceps was used in UTB-VBN-EBUS group and TB1-VBN-EBUS-GS group, while a standard forceps was used in TB2-VBN-EBUS-GS group. Primary endpoint is the diagnostic yield. The secondary endpoints include total examination time, the time from bronchoscope insertion of the glottis to the time of removing from the glottis; duration time of finding lesions, the time from insertion of ultrasound probe to withdrawal of ultrasound probe when a rEBUS view was seen; the proportion of lesions visible by rEBUS; factors affecting the diagnostic yield, difference in the bronchus level reached with the bronchoscope; difference in diagnostic yield; and complication rate. Complication rate includes adverse events related to the procedure during or within 1 month after the operation.

Study Type

Interventional

Enrollment (Estimated)

465

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Contact

Study Locations

      • Shanghai, China
        • Shanghai Chest Hospital
        • Contact:
    • Beijing
      • Beijing, Beijing, China, 100034
        • Peking University First Hospital
    • Henan
      • Zhengzhou, Henan, China, 450003
        • Henan Provincial People's Hospital
    • Jiangsu
      • Nanjing, Jiangsu, China, 210009
        • Zhongda Hospital Southeast University
    • Zhejiang
      • Ningbo, Zhejiang, China, 315020
        • The first affiliated hospital of Ningbo university

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

  • Adult
  • Older Adult

Accepts Healthy Volunteers

No

Description

Inclusion Criteria:

  • Patients older than 18 years old.
  • Chest imaging shows the presence of peripheral pulmonary lesions (defined as those lesions that are surrounded by pulmonary parenchyma and located below the segmental bronchus) that need to be confirmed by pathology. The length diameter of the lesion is no less than 8 mm and no more than 30mm.
  • Patients without contraindications of bronchoscopy.
  • Patients have good medical adherence and signed informed consent.

Exclusion Criteria:

  • Peripheral pulmonary lesion is pure ground-glass opacity.
  • Visible lumen lesions in segment and above segment bronchus during bronchoscopy (evidence of endobronchial lesion, extrinsic compression, submucosal tumor, narrowing, inflammation or bleeding of the bronchus).
  • The target lesion has been treated.
  • Diffuse pulmonary lesions.
  • The investigators believe that patient has other conditions that are not suitable for the study.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Diagnostic
  • Allocation: Randomized
  • Interventional Model: Parallel Assignment
  • Masking: Single

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Experimental: UTB-VBN-EBUS
An ultrathin bronchoscope with an outer diameter of 3.0mm and a working channel of 1.7mm will be used in combination with VBN and EBUS. An outer diameter 1.5mm biopsy forceps and a 1.4mm cytology brush will be used for sample collection.
A UTB will be used to perform white light bronchoscopy, then the rEBUS probe was inserted into the working channel and advanced to the PPL to obtain a rEBUS view per the navigation path created by VBN workstation. The probe will be withdrawn from the working channel when an optimal rEBUS view obtained. A 1.5-mm biopsy forceps and 1.4-mm cytology brush will be used to collect samples through the working channel.
Experimental: TB1-VBN-EBUS-GS
A thin bronchoscope with an outer diameter of 3.3mm and a working channel of 2.0mm will be used in combination with VBN and EBUS. A guide sheath with an outer diameter of 1.95mm, a 1.5mm biopsy forceps, and a 1.4mm cytology brush will be used for sample collection.
A thin bronchoscope will be used to perform white light bronchoscopy. A biopsy kit, including a 1.95-mm outer diameter guide sheath, 1.5-mm biopsy forceps, and 1.4-mm cytology brush, will be used to obtain samples with the guidance of VBN.
Experimental: TB2-VBN-EBUS-GS
A thin bronchoscope with an outer diameter of 4.2mm and a working channel of 2.8mm will be used in combination with VBN and EBUS. A guide sheath with an outer diameter of 2.55mm, a 1.9mm biopsy forceps, and a 1.8mm cytology brush will be used for sample collection.
A thin bronchoscope will be used to perform white light bronchoscopy. A biopsy kit, including a 2.55-mm outer diameter guide sheath, 1.9-mm biopsy forceps, and 1.8-mm cytology brush, will be used to obtain samples with the guidance of VBN.

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Diagnostic yield
Time Frame: up to 6 months
Diagnostic yield of ultrathin and thin bronchoscope for peripheral pulmonary nodules
up to 6 months

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Total examination time
Time Frame: During the procedure
Total examination time is defined from the time that the bronchoscope is inserted beyond the glottis, until the bronchoscope has been removed from the glottis after examination
During the procedure
Duration of finding lesions
Time Frame: During the procedure
Duration of finding lesions defined from insertion of ultrasound probe to withdrawal of ultrasound probe
During the procedure
Difference in the bronchus level reached with the bronchoscope
Time Frame: During the procedure
Level: Bronchus is level 0, leaf bronchus is level 1, segment bronchus is level 2, sub-segment bronchus is level 3, and so on, such as: LB3a is level 3
During the procedure
Complication rate
Time Frame: 1 month
The complications refer to the total of serious adverse events related to the procedure during or within 1 month after the operation.
1 month
Factors affecting the diagnosis yield
Time Frame: Up to 6 months
The factors affecting the diagnostic yield includes the nodules nature, size, location, the position of the ultrasound probe relative to the lesions etc.
Up to 6 months
Difference in diagnostic yield between the two novel thin bronchoscopes groups
Time Frame: Up to 6 months
Difference in diagnostic yield between the two novel thin bronchoscopes with guide sheath combined small biopsy forceps and conventional biopsy forceps.
Up to 6 months

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Publications and helpful links

The person responsible for entering information about the study voluntarily provides these publications. These may be about anything related to the study.

General Publications

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Estimated)

September 1, 2025

Primary Completion (Estimated)

July 31, 2026

Study Completion (Estimated)

August 31, 2026

Study Registration Dates

First Submitted

July 22, 2025

First Submitted That Met QC Criteria

August 14, 2025

First Posted (Actual)

August 22, 2025

Study Record Updates

Last Update Posted (Actual)

August 22, 2025

Last Update Submitted That Met QC Criteria

August 14, 2025

Last Verified

August 1, 2025

More Information

Terms related to this study

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

NO

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Lung Cancer (Diagnosis)

Clinical Trials on Ultrathin bronchoscope (UTB)

Subscribe