Closed-Loop Fluid Administration System Using Hemodynamic Monitors
Přehled studie
Postavení
Postavení
Podmínky
Podmínky
Intervence / Léčba
Intervence / Léčba
Detailní popis
Typ studie
Typ studie
Zápis (Aktuální)
Zápis
Fáze
Fáze
- Nelze použít
Kontakty a umístění
Studijní místa
-
-
California
-
Orange, California, Spojené státy, 92858
- University of California, Irvine Medical Center
-
-
Kritéria účasti
Kritéria způsobilosti
Kritéria způsobilosti
Věk způsobilý ke studiu
Přijímá zdravé dobrovolníky
Pohlaví způsobilá ke studiu
Popis
Inclusion Criteria:
- Adult subjects (over the age of 18)
- Subjects undergoing elective major, abdominal surgery
- Subjects requiring general anesthesia and mechanical ventilation
- Subjects requiring cardiac output monitoring and an arterial line
Exclusion Criteria:
- Subjects under 18 years of age
- Subjects not undergoing surgery
- Subjects not requiring general anesthesia or mechanical ventilation
- Subjects not requiring cardiac output monitoring or an arterial line
- Subjects who are pregnant
- Subjects without the capacity to give informed consent
Studijní plán
Jak je studie koncipována?
Detaily designu
- Primární účel: Léčba
- Přidělení: N/A
- Intervenční model: Přiřazení jedné skupiny
- Maskování: Žádné (otevřený štítek)
Počet zbraní
Zbraně a zásahy
Skupina účastníků / ArmSkupina účastníků / Arm |
Intervence / LéčbaIntervence / Léčba |
|---|---|
|
Experimentální: Closed Loop
Study patients will receive a baseline crystalloid infusion of 3 cc/kg/hr and all additional fluid management will be performed via a closed loop (automated) system that will determine rate, amount, and timing of fluid administration.
|
Fluid management in the closed loop group will be performed via a closed loop (automated) system that will use an infusion pump (Q-Core) and a controller (a computer run index and algorithm developed by Sironis) to make frequent, regular and accurate adjustments to the amount of fluid the patient receives using feedback from standard operating room monitors.
|
Co je měření studie?
Primární výstupní opatření
Primární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Fluid Status During Surgery
Časové okno: Duration of Surgery, up to 8 hours
|
The primary outcome between groups is preload independence, defined as % case time where Stroke Volume Variation (SVV) is ≤12%.
|
Duration of Surgery, up to 8 hours
|
Spolupracovníci a vyšetřovatelé
Sponzor
Sponzor
Vyšetřovatelé
Vyšetřovatelé
- Vrchní vyšetřovatel: Maxime Cannesson, MD, PhD, University of California, Irvine
Publikace a užitečné odkazy
Obecné publikace
- Pearse R, Dawson D, Fawcett J, Rhodes A, Grounds RM, Bennett ED. Early goal-directed therapy after major surgery reduces complications and duration of hospital stay. A randomised, controlled trial [ISRCTN38797445]. Crit Care. 2005;9(6):R687-93. doi: 10.1186/cc3887. Epub 2005 Nov 8.
- Rinehart J, Liu N, Alexander B, Cannesson M. Review article: closed-loop systems in anesthesia: is there a potential for closed-loop fluid management and hemodynamic optimization? Anesth Analg. 2012 Jan;114(1):130-43. doi: 10.1213/ANE.0b013e318230e9e0. Epub 2011 Sep 29.
- Bednarski P, Siclari F, Voigt A, Demertzis S, Lau G. Use of a computerized closed-loop sodium nitroprusside titration system for antihypertensive treatment after open heart surgery. Crit Care Med. 1990 Oct;18(10):1061-5. doi: 10.1097/00003246-199010000-00002.
- Colvin JR, Kenny GN. Development and evaluation of a dual-pump microcomputer-based closed-loop arterial pressure control system. Int J Clin Monit Comput. 1989 Jan;6(1):31-5. doi: 10.1007/BF01723370.
- Blankenship HB, Wallace FD, Pacifico AD. Clinical application of closed-loop postoperative autotransfusion. Med Prog Technol. 1990 May;16(1-2):89-93.
- Bowman RJ, Westenskow DR. A microcomputer-based fluid infusion system for the resuscitation of burn patients. IEEE Trans Biomed Eng. 1981 Jun;28(6):475-9. doi: 10.1109/TBME.1981.324822. No abstract available.
- Chaisson NF, Kirschner RA, Deyo DJ, Lopez JA, Prough DS, Kramer GC. Near-infrared spectroscopy-guided closed-loop resuscitation of hemorrhage. J Trauma. 2003 May;54(5 Suppl):S183-92. doi: 10.1097/01.TA.0000064508.11512.28.
- DeBey RK, Westenskow DR, Jordan WS, McJames SW. A urine based control system for fluid infusion. Biomed Sci Instrum. 1987;23:195-8. No abstract available.
- Rinehart J, Alexander B, Le Manach Y, Hofer C, Tavernier B, Kain ZN, Cannesson M. Evaluation of a novel closed-loop fluid-administration system based on dynamic predictors of fluid responsiveness: an in silico simulation study. Crit Care. 2011;15(6):R278. doi: 10.1186/cc10562. Epub 2011 Nov 23.
- Rinehart J, Lee C, Cannesson M, Dumont G. Closed-loop fluid resuscitation: robustness against weight and cardiac contractility variations. Anesth Analg. 2013 Nov;117(5):1110-8. doi: 10.1213/ANE.0b013e3182930050.
- Rinehart J, Lee C, Canales C, Kong A, Kain Z, Cannesson M. Closed-loop fluid administration compared to anesthesiologist management for hemodynamic optimization and resuscitation during surgery: an in vivo study. Anesth Analg. 2013 Nov;117(5):1119-29. doi: 10.1213/ANE.0b013e3182937d61.
- Forget P, Lois F, de Kock M. Goal-directed fluid management based on the pulse oximeter-derived pleth variability index reduces lactate levels and improves fluid management. Anesth Analg. 2010 Oct;111(4):910-4. doi: 10.1213/ANE.0b013e3181eb624f. Epub 2010 Aug 12.
- Rinehart J, Chung E, Canales C, Cannesson M. Intraoperative stroke volume optimization using stroke volume, arterial pressure, and heart rate: closed-loop (learning intravenous resuscitator) versus anesthesiologists. J Cardiothorac Vasc Anesth. 2012 Oct;26(5):933-9. doi: 10.1053/j.jvca.2012.05.015. Epub 2012 Jul 12.
- Rinehart J, Lilot M, Lee C, Joosten A, Huynh T, Canales C, Imagawa D, Demirjian A, Cannesson M. Closed-loop assisted versus manual goal-directed fluid therapy during high-risk abdominal surgery: a case-control study with propensity matching. Crit Care. 2015 Mar 19;19(1):94. doi: 10.1186/s13054-015-0827-7.
- Joosten A, Huynh T, Suehiro K, Canales C, Cannesson M, Rinehart J. Goal-Directed fluid therapy with closed-loop assistance during moderate risk surgery using noninvasive cardiac output monitoring: A pilot study. Br J Anaesth. 2015 Jun;114(6):886-92. doi: 10.1093/bja/aev002. Epub 2015 Feb 17.
Užitečné odkazy
Termíny studijních záznamů
Hlavní termíny studia
Začátek studia
Začátek studia
Primární dokončení (Aktuální)
Primární dokončení
Dokončení studie (Aktuální)
Dokončení studie
Termíny zápisu do studia
První předloženo
První předloženo
První předloženo, které splnilo kritéria kontroly kvality
První předloženo, které splnilo kritéria kontroly kvality
První zveřejněno (Odhad)
První zveřejněno
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Odhad)
Poslední zveřejněná aktualizace
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Naposledy ověřeno
Naposledy ověřeno
Více informací
Termíny související s touto studií
Další relevantní podmínky MeSH
Další identifikační čísla studie
Další identifikační čísla studie
- UCIANES03
Plán pro data jednotlivých účastníků (IPD)
Plánujete sdílet data jednotlivých účastníků (IPD)?
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .