Closed-Loop Fluid Administration System Using Hemodynamic Monitors
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
California
-
Orange, California, United States, 92858
- University of California, Irvine Medical Center
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Adult subjects (over the age of 18)
- Subjects undergoing elective major, abdominal surgery
- Subjects requiring general anesthesia and mechanical ventilation
- Subjects requiring cardiac output monitoring and an arterial line
Exclusion Criteria:
- Subjects under 18 years of age
- Subjects not undergoing surgery
- Subjects not requiring general anesthesia or mechanical ventilation
- Subjects not requiring cardiac output monitoring or an arterial line
- Subjects who are pregnant
- Subjects without the capacity to give informed consent
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Closed Loop
Study patients will receive a baseline crystalloid infusion of 3 cc/kg/hr and all additional fluid management will be performed via a closed loop (automated) system that will determine rate, amount, and timing of fluid administration.
|
Fluid management in the closed loop group will be performed via a closed loop (automated) system that will use an infusion pump (Q-Core) and a controller (a computer run index and algorithm developed by Sironis) to make frequent, regular and accurate adjustments to the amount of fluid the patient receives using feedback from standard operating room monitors.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Fluid Status During Surgery
Time Frame: Duration of Surgery, up to 8 hours
|
The primary outcome between groups is preload independence, defined as % case time where Stroke Volume Variation (SVV) is ≤12%.
|
Duration of Surgery, up to 8 hours
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Maxime Cannesson, MD, PhD, University of California, Irvine
Publications and helpful links
General Publications
- Pearse R, Dawson D, Fawcett J, Rhodes A, Grounds RM, Bennett ED. Early goal-directed therapy after major surgery reduces complications and duration of hospital stay. A randomised, controlled trial [ISRCTN38797445]. Crit Care. 2005;9(6):R687-93. doi: 10.1186/cc3887. Epub 2005 Nov 8.
- Rinehart J, Liu N, Alexander B, Cannesson M. Review article: closed-loop systems in anesthesia: is there a potential for closed-loop fluid management and hemodynamic optimization? Anesth Analg. 2012 Jan;114(1):130-43. doi: 10.1213/ANE.0b013e318230e9e0. Epub 2011 Sep 29.
- Bednarski P, Siclari F, Voigt A, Demertzis S, Lau G. Use of a computerized closed-loop sodium nitroprusside titration system for antihypertensive treatment after open heart surgery. Crit Care Med. 1990 Oct;18(10):1061-5. doi: 10.1097/00003246-199010000-00002.
- Colvin JR, Kenny GN. Development and evaluation of a dual-pump microcomputer-based closed-loop arterial pressure control system. Int J Clin Monit Comput. 1989 Jan;6(1):31-5. doi: 10.1007/BF01723370.
- Blankenship HB, Wallace FD, Pacifico AD. Clinical application of closed-loop postoperative autotransfusion. Med Prog Technol. 1990 May;16(1-2):89-93.
- Bowman RJ, Westenskow DR. A microcomputer-based fluid infusion system for the resuscitation of burn patients. IEEE Trans Biomed Eng. 1981 Jun;28(6):475-9. doi: 10.1109/TBME.1981.324822. No abstract available.
- Chaisson NF, Kirschner RA, Deyo DJ, Lopez JA, Prough DS, Kramer GC. Near-infrared spectroscopy-guided closed-loop resuscitation of hemorrhage. J Trauma. 2003 May;54(5 Suppl):S183-92. doi: 10.1097/01.TA.0000064508.11512.28.
- DeBey RK, Westenskow DR, Jordan WS, McJames SW. A urine based control system for fluid infusion. Biomed Sci Instrum. 1987;23:195-8. No abstract available.
- Rinehart J, Alexander B, Le Manach Y, Hofer C, Tavernier B, Kain ZN, Cannesson M. Evaluation of a novel closed-loop fluid-administration system based on dynamic predictors of fluid responsiveness: an in silico simulation study. Crit Care. 2011;15(6):R278. doi: 10.1186/cc10562. Epub 2011 Nov 23.
- Rinehart J, Lee C, Cannesson M, Dumont G. Closed-loop fluid resuscitation: robustness against weight and cardiac contractility variations. Anesth Analg. 2013 Nov;117(5):1110-8. doi: 10.1213/ANE.0b013e3182930050.
- Rinehart J, Lee C, Canales C, Kong A, Kain Z, Cannesson M. Closed-loop fluid administration compared to anesthesiologist management for hemodynamic optimization and resuscitation during surgery: an in vivo study. Anesth Analg. 2013 Nov;117(5):1119-29. doi: 10.1213/ANE.0b013e3182937d61.
- Forget P, Lois F, de Kock M. Goal-directed fluid management based on the pulse oximeter-derived pleth variability index reduces lactate levels and improves fluid management. Anesth Analg. 2010 Oct;111(4):910-4. doi: 10.1213/ANE.0b013e3181eb624f. Epub 2010 Aug 12.
- Rinehart J, Chung E, Canales C, Cannesson M. Intraoperative stroke volume optimization using stroke volume, arterial pressure, and heart rate: closed-loop (learning intravenous resuscitator) versus anesthesiologists. J Cardiothorac Vasc Anesth. 2012 Oct;26(5):933-9. doi: 10.1053/j.jvca.2012.05.015. Epub 2012 Jul 12.
- Rinehart J, Lilot M, Lee C, Joosten A, Huynh T, Canales C, Imagawa D, Demirjian A, Cannesson M. Closed-loop assisted versus manual goal-directed fluid therapy during high-risk abdominal surgery: a case-control study with propensity matching. Crit Care. 2015 Mar 19;19(1):94. doi: 10.1186/s13054-015-0827-7.
- Joosten A, Huynh T, Suehiro K, Canales C, Cannesson M, Rinehart J. Goal-Directed fluid therapy with closed-loop assistance during moderate risk surgery using noninvasive cardiac output monitoring: A pilot study. Br J Anaesth. 2015 Jun;114(6):886-92. doi: 10.1093/bja/aev002. Epub 2015 Feb 17.
Helpful Links
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Estimate)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- UCIANES03
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.