Closed-Loop Fluid Administration System Using Hemodynamic Monitors
Tutkimuksen yleiskatsaus
Tila
Tila
Ehdot
Ehdot
Interventio / Hoito
Interventio / Hoito
Yksityiskohtainen kuvaus
Opintotyyppi
Opintotyyppi
Ilmoittautuminen (Todellinen)
Ilmoittautuminen
Vaihe
Vaihe
- Ei sovellettavissa
Yhteystiedot ja paikat
Opiskelupaikat
-
-
California
-
Orange, California, Yhdysvallat, 92858
- University of California, Irvine Medical Center
-
-
Osallistumiskriteerit
Kelpoisuusvaatimukset
Kelpoisuusvaatimukset
Opintokelpoiset iät
Hyväksyy terveitä vapaaehtoisia
Sukupuolet, jotka voivat opiskella
Kuvaus
Inclusion Criteria:
- Adult subjects (over the age of 18)
- Subjects undergoing elective major, abdominal surgery
- Subjects requiring general anesthesia and mechanical ventilation
- Subjects requiring cardiac output monitoring and an arterial line
Exclusion Criteria:
- Subjects under 18 years of age
- Subjects not undergoing surgery
- Subjects not requiring general anesthesia or mechanical ventilation
- Subjects not requiring cardiac output monitoring or an arterial line
- Subjects who are pregnant
- Subjects without the capacity to give informed consent
Opintosuunnitelma
Miten tutkimus on suunniteltu?
Suunnittelun yksityiskohdat
- Ensisijainen käyttötarkoitus: Hoito
- Jako: Ei käytössä
- Inventiomalli: Yksittäinen ryhmätehtävä
- Naamiointi: Ei mitään (avoin tarra)
Aseiden lukumäärä
Aseet ja interventiot
Osallistujaryhmä / ArmOsallistujaryhmä / Arm |
Interventio / HoitoInterventio / Hoito |
|---|---|
|
Kokeellinen: Closed Loop
Study patients will receive a baseline crystalloid infusion of 3 cc/kg/hr and all additional fluid management will be performed via a closed loop (automated) system that will determine rate, amount, and timing of fluid administration.
|
Fluid management in the closed loop group will be performed via a closed loop (automated) system that will use an infusion pump (Q-Core) and a controller (a computer run index and algorithm developed by Sironis) to make frequent, regular and accurate adjustments to the amount of fluid the patient receives using feedback from standard operating room monitors.
|
Mitä tutkimuksessa mitataan?
Ensisijaiset tulostoimenpiteet
Ensisijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
Fluid Status During Surgery
Aikaikkuna: Duration of Surgery, up to 8 hours
|
The primary outcome between groups is preload independence, defined as % case time where Stroke Volume Variation (SVV) is ≤12%.
|
Duration of Surgery, up to 8 hours
|
Yhteistyökumppanit ja tutkijat
Sponsori
Sponsori
Tutkijat
Tutkijat
- Päätutkija: Maxime Cannesson, MD, PhD, University of California, Irvine
Julkaisuja ja hyödyllisiä linkkejä
Yleiset julkaisut
- Pearse R, Dawson D, Fawcett J, Rhodes A, Grounds RM, Bennett ED. Early goal-directed therapy after major surgery reduces complications and duration of hospital stay. A randomised, controlled trial [ISRCTN38797445]. Crit Care. 2005;9(6):R687-93. doi: 10.1186/cc3887. Epub 2005 Nov 8.
- Rinehart J, Liu N, Alexander B, Cannesson M. Review article: closed-loop systems in anesthesia: is there a potential for closed-loop fluid management and hemodynamic optimization? Anesth Analg. 2012 Jan;114(1):130-43. doi: 10.1213/ANE.0b013e318230e9e0. Epub 2011 Sep 29.
- Bednarski P, Siclari F, Voigt A, Demertzis S, Lau G. Use of a computerized closed-loop sodium nitroprusside titration system for antihypertensive treatment after open heart surgery. Crit Care Med. 1990 Oct;18(10):1061-5. doi: 10.1097/00003246-199010000-00002.
- Colvin JR, Kenny GN. Development and evaluation of a dual-pump microcomputer-based closed-loop arterial pressure control system. Int J Clin Monit Comput. 1989 Jan;6(1):31-5. doi: 10.1007/BF01723370.
- Blankenship HB, Wallace FD, Pacifico AD. Clinical application of closed-loop postoperative autotransfusion. Med Prog Technol. 1990 May;16(1-2):89-93.
- Bowman RJ, Westenskow DR. A microcomputer-based fluid infusion system for the resuscitation of burn patients. IEEE Trans Biomed Eng. 1981 Jun;28(6):475-9. doi: 10.1109/TBME.1981.324822. No abstract available.
- Chaisson NF, Kirschner RA, Deyo DJ, Lopez JA, Prough DS, Kramer GC. Near-infrared spectroscopy-guided closed-loop resuscitation of hemorrhage. J Trauma. 2003 May;54(5 Suppl):S183-92. doi: 10.1097/01.TA.0000064508.11512.28.
- DeBey RK, Westenskow DR, Jordan WS, McJames SW. A urine based control system for fluid infusion. Biomed Sci Instrum. 1987;23:195-8. No abstract available.
- Rinehart J, Alexander B, Le Manach Y, Hofer C, Tavernier B, Kain ZN, Cannesson M. Evaluation of a novel closed-loop fluid-administration system based on dynamic predictors of fluid responsiveness: an in silico simulation study. Crit Care. 2011;15(6):R278. doi: 10.1186/cc10562. Epub 2011 Nov 23.
- Rinehart J, Lee C, Cannesson M, Dumont G. Closed-loop fluid resuscitation: robustness against weight and cardiac contractility variations. Anesth Analg. 2013 Nov;117(5):1110-8. doi: 10.1213/ANE.0b013e3182930050.
- Rinehart J, Lee C, Canales C, Kong A, Kain Z, Cannesson M. Closed-loop fluid administration compared to anesthesiologist management for hemodynamic optimization and resuscitation during surgery: an in vivo study. Anesth Analg. 2013 Nov;117(5):1119-29. doi: 10.1213/ANE.0b013e3182937d61.
- Forget P, Lois F, de Kock M. Goal-directed fluid management based on the pulse oximeter-derived pleth variability index reduces lactate levels and improves fluid management. Anesth Analg. 2010 Oct;111(4):910-4. doi: 10.1213/ANE.0b013e3181eb624f. Epub 2010 Aug 12.
- Rinehart J, Chung E, Canales C, Cannesson M. Intraoperative stroke volume optimization using stroke volume, arterial pressure, and heart rate: closed-loop (learning intravenous resuscitator) versus anesthesiologists. J Cardiothorac Vasc Anesth. 2012 Oct;26(5):933-9. doi: 10.1053/j.jvca.2012.05.015. Epub 2012 Jul 12.
- Rinehart J, Lilot M, Lee C, Joosten A, Huynh T, Canales C, Imagawa D, Demirjian A, Cannesson M. Closed-loop assisted versus manual goal-directed fluid therapy during high-risk abdominal surgery: a case-control study with propensity matching. Crit Care. 2015 Mar 19;19(1):94. doi: 10.1186/s13054-015-0827-7.
- Joosten A, Huynh T, Suehiro K, Canales C, Cannesson M, Rinehart J. Goal-Directed fluid therapy with closed-loop assistance during moderate risk surgery using noninvasive cardiac output monitoring: A pilot study. Br J Anaesth. 2015 Jun;114(6):886-92. doi: 10.1093/bja/aev002. Epub 2015 Feb 17.
Hyödyllisiä linkkejä
Opintojen ennätyspäivät
Opi tärkeimmät päivämäärät
Opiskelun aloitus
Opiskelun aloitus
Ensisijainen valmistuminen (Todellinen)
Ensisijainen valmistuminen
Opintojen valmistuminen (Todellinen)
Opintojen valmistuminen
Opintoihin ilmoittautumispäivät
Ensimmäinen lähetetty
Ensimmäinen lähetetty
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen Lähetetty (Arvio)
Ensimmäinen Lähetetty
Tutkimustietojen päivitykset
Viimeisin päivitys julkaistu (Arvio)
Viimeisin päivitys julkaistu
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeksi vahvistettu
Viimeksi vahvistettu
Lisää tietoa
Tähän tutkimukseen liittyvät termit
Muita asiaankuuluvia MeSH-ehtoja
Muut tutkimustunnusnumerot
Muut tutkimustunnusnumerot
- UCIANES03
Yksittäisten osallistujien tietojen suunnitelma (IPD)
Aiotko jakaa yksittäisten osallistujien tietoja (IPD)?
Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .