Denne side blev automatisk oversat, og nøjagtigheden af ​​oversættelsen er ikke garanteret. Der henvises til engelsk version for en kildetekst.

Evaluering af membranlungefunktion i højhøjdeområder

4. november 2026 opdateret af: Rui Wang, Beijing Chao Yang Hospital

Evaluering af membranlungefunktion for patienter, der modtager venovenøs ekstrakorporal membraniltning i højhøjdeområder

Over the last 20 years, extracorporeal membrane oxygenation (ECMO) has been used to support adult patients with respiratory or cardiac failure who are unlikely to survive conventional treatment methods. ECMO circuit, pump, and oxygenator technology improvements permit safer perfusion for extended periods. The prolonged use of an ECMO circuit increases the risk of membrane lung (ML) dysfunction. The ML is responsible for taking in oxygen and removing carbon dioxide. The non-biologic surface of the ML triggers inflammatory and coagulation pathways, resulting in the formation of blood clots, breakdown of fibrin, and activation of white blood cells, which ultimately leads to ML dysfunction. Coagulation and fibrinolysis activation can cause systemic coagulopathy or hemolysis, and the deposition of blood clots can block blood flow. Moreover, the accumulation of moisture in the gas phase and the buildup of protein and cellular debris in the blood phase may contribute to shunt and dead-space physiology, respectively, impairing the exchange of gases. These three categories-hematologic abnormalities, mechanical obstruction, and inadequate gas exchange-account for most ML exchanges. Worsening oxygenation during ECMO should prompt quantification of oxygen transfer. ML exchange is indicated when the ML can no longer meet the patient's oxygen demand. The partial pressure of Post-ML arterial oxygen less than 200 mmHg is the most important consideration in this decision. In some high-altitude regions of China, ECMO treatment is also routinely conducted. The experiences above are derived from low-altitude areas, and whether they apply in high-altitude regions is still being determined. This study aimed to explore the significantly lower membrane lung oxygen uptake in high-altitude regions compared to low-altitude areas.

Studieoversigt

Status

Afsluttet

Betingelser

Intervention / Behandling

Undersøgelsestype

Observationel

Tilmelding (Faktiske)

60

Kontakter og lokationer

Dette afsnit indeholder kontaktoplysninger for dem, der udfører undersøgelsen, og oplysninger om, hvor denne undersøgelse udføres.

Studiesteder

    • Beijing Municipality
      • Beijing, Beijing Municipality, Kina, 100020
        • Beijing Chao-Yang Hospital

Deltagelseskriterier

Forskere leder efter personer, der passer til en bestemt beskrivelse, kaldet berettigelseskriterier. Nogle eksempler på disse kriterier er en persons generelle helbredstilstand eller tidligere behandlinger.

Berettigelseskriterier

Aldre berettiget til at studere

18 år til 70 år (Voksen, Ældre voksen)

Tager imod sunde frivillige

N/A

Køn, der er berettiget til at studere

Alle

Prøveudtagningsmetode

Ikke-sandsynlighedsprøve

Studiebefolkning

Patients who are supported by ECMO

Beskrivelse

Inclusion Criteria:

  • Receiving ECMO support

Exclusion Criteria:

  • Unable to obtain post-membrane blood gas
  • Pregnancy
  • Patients cannot receive anticoagulation
  • Refusal to participate in the trial

Studieplan

Dette afsnit indeholder detaljer om studieplanen, herunder hvordan undersøgelsen er designet, og hvad undersøgelsen måler.

Hvordan er undersøgelsen tilrettelagt?

Design detaljer

  • Observationsmodeller: COHORT
  • Tidsperspektiver: PROSPECTIVE

Kohorter og interventioner

Gruppe / kohorte
Intervention / Behandling
Højtliggende gruppe

The altitude in Beijing is 100m, while the altitude in Xining, Qinghai is 2600m. We will monitor the partial pressure of post-ML arterial oxygen in ECMO patients in these two locations and evaluate whether the normal values of membrane lung function are consistent in different altitudes.

Lavhøjdegruppe

The altitude in Beijing is 100m, while the altitude in Xining, Qinghai is 2600m. We will monitor the partial pressure of post-ML arterial oxygen in ECMO patients in these two locations and evaluate whether the normal values of membrane lung function are consistent in different altitudes.

Hvad måler undersøgelsen?

Primære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
Initial assessment of membrane lung oxygen uptake
Tidsramme: On the third day of ECMO support

O2 content of post-ML blood - O2 content of pre-ML blood

On the third day of ECMO support

Sekundære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
60-day mortality
Tidsramme: After patients enrolled 60 days

Mortality rate at 60 days of VV-ECMO support

After patients enrolled 60 days

Samarbejdspartnere og efterforskere

Det er her, du vil finde personer og organisationer, der er involveret i denne undersøgelse.

Sponsor

Samarbejdspartnere

Efterforskere

  • Studieleder: Rui Wang, Dr., Beijing Chao-Yang Hospital, Capital Medical University, Beijing, China

Publikationer og nyttige links

Den person, der er ansvarlig for at indtaste oplysninger om undersøgelsen, leverer frivilligt disse publikationer. Disse kan handle om alt relateret til undersøgelsen.

Datoer for undersøgelser

Disse datoer sporer fremskridtene for indsendelser af undersøgelsesrekord og resumeresultater til ClinicalTrials.gov. Studieregistreringer og rapporterede resultater gennemgås af National Library of Medicine (NLM) for at sikre, at de opfylder specifikke kvalitetskontrolstandarder, før de offentliggøres på den offentlige hjemmeside.

Studer store datoer

Studiestart (Faktiske)

5. december 2023

Primær færdiggørelse (Faktiske)

30. december 2025

Studieafslutning (Faktiske)

31. december 2025

Datoer for studieregistrering

Først indsendt

22. november 2023

Først indsendt, der opfyldte QC-kriterier

22. november 2023

Først opslået (Faktiske)

1. december 2023

Opdateringer af undersøgelsesjournaler

Sidste opdatering sendt (Faktiske)

6. november 2026

Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier

4. november 2026

Sidst verificeret

1. juni 2026

Mere information

Begreber relateret til denne undersøgelse

Yderligere relevante MeSH-vilkår

Andre undersøgelses-id-numre

  • 2023-KE-1121

Plan for individuelle deltagerdata (IPD)

Planlægger du at dele individuelle deltagerdata (IPD)?

INGEN

Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter

Studerer et amerikansk FDA-reguleret lægemiddelprodukt

Ingen

Studerer et amerikansk FDA-reguleret enhedsprodukt

Ingen

Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .