Lav-intensiv mekanisk ventilation i operationsstuen: en pilotundersøgelse (VIOLET)
Lavintensiv mekanisk ventilation i operationsstuen: et pilotstudie
The aim of the study is to assess whether a bundle of protective low-intensity mechanical ventilation interventions reduces perioperative atelectasis and postoperative pulmonary complications, compared with standard care in a robot-assisted surgical setting. The feasibility of this ventilation bundle will also be assessed.
Studieoversigt
Status
Status
Betingelser
Betingelser
Intervention / Behandling
Intervention / Behandling
Detaljeret beskrivelse
The investigators hypothesize that protective low-intensity mechanical ventilation during robot-assisted surgery reduces perioperative atelectasis and postoperative pulmonary complications.
Undersøgelsestype
Undersøgelsestype
Tilmelding (Faktiske)
Tilmelding
Fase
Fase
- Ikke anvendelig
Kontakter og lokationer
Studiesteder
-
-
Massachusetts
-
Boston, Massachusetts, Forenede Stater, 02115
- Beth Israel Deaconess Medical Center
-
-
Deltagelseskriterier
Berettigelseskriterier
Berettigelseskriterier
Aldre berettiget til at studere
Tager imod sunde frivillige
Køn, der er berettiget til at studere
Beskrivelse
Inclusion Criteria:
- Adult patients undergoing non-emergent intra-abdominal or pelvic robot-assisted surgery with an expected duration of at least 2 hours, under general anesthesia with planned extubation at the end of the procedure
Exclusion Criteria:
- Known pregnancy
- Pre-existing intubation or tracheostomy
- Contraindications for esophageal manometry: severe midface trauma or recent nasal surgery, esophageal varices, recent gastric or esophageal surgery
- Contraindications for electrical impedance tomography (EIT): inability to place EIT belt, presence of an active electronic implantable device (e.g., pacemaker, ICD)
Studieplan
Hvordan er undersøgelsen tilrettelagt?
Design detaljer
- Primært formål: Behandling
- Tildeling: Randomiseret
- Interventionel model: Parallel tildeling
- Maskning: Enkelt
Antal våben
Våben og indgreb
Deltagergruppe / ArmDeltagergruppe / Arm |
Intervention / BehandlingIntervention / Behandling |
|---|---|
|
Ingen indgriben: Control
A guided standard of care protocol will be applied in the control group. This includes a PEEP of 5 cmH₂O, with adjustment by the anesthesia provider if SpO₂ falls below 96% or whenever deemed clinically necessary, a tidal volume of 6-10 mL/kg predicted body weight, and a respiratory rate adjusted to maintain end-tidal CO₂ between 35 and 45 mmHg throughout anesthesia. FiO₂ will be set to 100% during the washout phase at the end of surgery to limit resorption atelectasis. |
|
|
Eksperimentel: Intervention
A bundle of protective low-intensity mechanical ventilation strategies will be applied throughout the procedure. All interventions consist of modification of ventilator settings. |
A bundle of protective low-intensity mechanical ventilation strategies will be applied throughout the procedure:
|
Hvad måler undersøgelsen?
Primære resultatmål
Primære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
ΔEELV between baseline and after extubation before leaving the operating room.
Tidsramme: Perioperative Day 0: From pre-intubation baseline in the operating room (prior to induction of anesthesia) to the first post-extubation EIT assessment (within 10 min after extubation on Day 0).
|
Change in end-expiratory lung volume (EELV), measured using electrical impedance tomography between baseline and after extubation before leaving the operating room. |
Perioperative Day 0: From pre-intubation baseline in the operating room (prior to induction of anesthesia) to the first post-extubation EIT assessment (within 10 min after extubation on Day 0).
|
Sekundære resultatmål
Sekundære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Proportion of patients with postoperative pulmonary complications at day 7
Tidsramme: This secondary outcome will be assessed in the time between day of surgery until 7 days after the day of surgery
|
Re-intubation, hypoxemia requiring oxygen therapy, pleural effusion, pneumonia, atelectasis or emergency non-invasive ventilation |
This secondary outcome will be assessed in the time between day of surgery until 7 days after the day of surgery
|
|
Recruitment rate
Tidsramme: Day 0
|
Proportion of patients enrolled in the study-defined as those who provided acceptance and signed informed consent-relative to all patients approached. |
Day 0
|
|
Intervention deliverability
Tidsramme: From intubation to extubation at Day 0
|
proportion of patients in the intervention arm in whom the full bundle of protective low-intensity ventilation strategies is delivered as planned across all predefined intraoperative phases. |
From intubation to extubation at Day 0
|
|
EELV
Tidsramme: Perioperative Day 0: before anesthesia, after intubation, after PEEP/TV/RR titration, after insufflation and positioning, after PEEP/TV/RR reassessment, just before extubation, after extubation, after PACU admission and 60min after PACU admission
|
End-expiratory lung volume measured by Electrical Impedance Tomography in mL |
Perioperative Day 0: before anesthesia, after intubation, after PEEP/TV/RR titration, after insufflation and positioning, after PEEP/TV/RR reassessment, just before extubation, after extubation, after PACU admission and 60min after PACU admission
|
|
COV
Tidsramme: Perioperative Day 0: before anesthesia, after intubation, after PEEP/TV/RR titration, after insufflation and positioning, after PEEP/TV/RR reassessment, just before extubation, after extubation, after PACU admission and 60min after PACU admission
|
Center of ventilation measured by Electrical Impedance Tomography in percentage |
Perioperative Day 0: before anesthesia, after intubation, after PEEP/TV/RR titration, after insufflation and positioning, after PEEP/TV/RR reassessment, just before extubation, after extubation, after PACU admission and 60min after PACU admission
|
|
RVDI
Tidsramme: Perioperative Day 0: before anesthesia, after intubation, after PEEP/TV/RR titration, after insufflation and positioning, after PEEP/TV/RR reassessment, just before extubation, after extubation, after PACU admission and 60min after PACU admission
|
Regional ventilation delay inhomogeneity measured by Electrical Impedance Tomography (unitless) |
Perioperative Day 0: before anesthesia, after intubation, after PEEP/TV/RR titration, after insufflation and positioning, after PEEP/TV/RR reassessment, just before extubation, after extubation, after PACU admission and 60min after PACU admission
|
|
GI
Tidsramme: Perioperative Day 0: before anesthesia, after intubation, after PEEP/TV/RR titration, after insufflation and positioning, after PEEP/TV/RR reassessment, just before extubation, after extubation, after PACU admission and 60min after PACU admission
|
Global inhomogeneity index measured by Electrical Impedance Tomography (unitless) |
Perioperative Day 0: before anesthesia, after intubation, after PEEP/TV/RR titration, after insufflation and positioning, after PEEP/TV/RR reassessment, just before extubation, after extubation, after PACU admission and 60min after PACU admission
|
|
Dorsal ROI
Tidsramme: Perioperative Day 0: before anesthesia, after intubation, after PEEP/TV/RR titration, after insufflation and positioning, after PEEP/TV/RR reassessment, just before extubation, after extubation, after PACU admission and 60min after PACU admission
|
Maximum dorsal ratio of impedance measured by Electrical Impedance Tomography (unitless) |
Perioperative Day 0: before anesthesia, after intubation, after PEEP/TV/RR titration, after insufflation and positioning, after PEEP/TV/RR reassessment, just before extubation, after extubation, after PACU admission and 60min after PACU admission
|
|
EEPL
Tidsramme: Perioperative Day 0: after intubation, after PEEP/TV/RR titration, after insufflation and positioning, after PEEP/TV/RR reassessment, just before extubation
|
End-expiratory transpulmonary pressure, calculated as airway pressure minus esophageal pressure (cmH₂O) |
Perioperative Day 0: after intubation, after PEEP/TV/RR titration, after insufflation and positioning, after PEEP/TV/RR reassessment, just before extubation
|
|
EIPL
Tidsramme: Perioperative Day 0: after intubation, after PEEP/TV/RR titration, after insufflation and positioning, after PEEP/TV/RR reassessment, just before extubation
|
End-inspiratory transpulmonary pressure, calculated as airway pressure minus esophageal pressure (cmH₂O) |
Perioperative Day 0: after intubation, after PEEP/TV/RR titration, after insufflation and positioning, after PEEP/TV/RR reassessment, just before extubation
|
|
Relationship between body mass index with optimal PEEP
Tidsramme: Intraoperative Day 0: after insufflation of pneumoperitoneum and positioning the patient for surgery
|
Correlation between BMI (kg/m²) and the optimal positive end-expiratory pressure (PEEP, cmH₂O) determined after pneumoperitoneum insufflation and patient positioning for surgery. |
Intraoperative Day 0: after insufflation of pneumoperitoneum and positioning the patient for surgery
|
|
Relationship of the degree of Trendelenburg inclination with optimal PEEP
Tidsramme: Intraoperative Day 0: after insufflation of pneumoperitoneum and positioning the patient for surgery
|
Correlation between the degree of Trendelenburg inclination (in degree) and the optimal positive end-expiratory pressure (PEEP, cmH₂O) determined after pneumoperitoneum insufflation and patient positioning for surgery. |
Intraoperative Day 0: after insufflation of pneumoperitoneum and positioning the patient for surgery
|
|
Relationship of the pneumoperitoneum (insufflation) with optimal PEEP
Tidsramme: Intraoperative Day 0: after insufflation of pneumoperitoneum and positioning the patient for surgery
|
Correlation between the pneumoperitoneum (insufflation in cmH2O) and the optimal positive end-expiratory pressure (PEEP, cmH₂O) determined after pneumoperitoneum insufflation and patient positioning for surgery. |
Intraoperative Day 0: after insufflation of pneumoperitoneum and positioning the patient for surgery
|
|
Intraoperative oxygenation
Tidsramme: Perioperative Day 0: before anesthesia, after intubation, after PEEP/TV/RR titration, after insufflation and positioning, after PEEP/TV/RR reassessment, just before extubation, after extubation
|
Intraoperative peripheral pulsed oxygen saturation (SpO2) |
Perioperative Day 0: before anesthesia, after intubation, after PEEP/TV/RR titration, after insufflation and positioning, after PEEP/TV/RR reassessment, just before extubation, after extubation
|
|
Postoperative oxygenation
Tidsramme: Postoperative Day 0: after PACU admission and 60min after PACU admission
|
Postoperative peripheral pulsed oxygen saturation (SpO2) |
Postoperative Day 0: after PACU admission and 60min after PACU admission
|
Samarbejdspartnere og efterforskere
Sponsor
Sponsor
Publikationer og nyttige links
Generelle publikationer
- Schaefer MS, Wania V, Bastin B, Schmalz U, Kienbaum P, Beiderlinden M, Treschan TA. Electrical impedance tomography during major open upper abdominal surgery: a pilot-study. BMC Anesthesiol. 2014 Jul 5;14:51. doi: 10.1186/1471-2253-14-51. eCollection 2014.
- Schaefer MS, Treschan TA, Gauch J, Neukirchen M, Kienbaum P. Influence of xenon on pulmonary mechanics and lung aeration in patients with healthy lungs. Br J Anaesth. 2018 Jun;120(6):1394-1400. doi: 10.1016/j.bja.2018.02.064. Epub 2018 Apr 13.
Datoer for undersøgelser
Studer store datoer
Studiestart (Faktiske)
Studiestart
Primær færdiggørelse (Faktiske)
Primær færdiggørelse
Studieafslutning (Faktiske)
Studieafslutning
Datoer for studieregistrering
Først indsendt
Først indsendt
Først indsendt, der opfyldte QC-kriterier
Først indsendt, der opfyldte QC-kriterier
Først opslået (Faktiske)
Først opslået
Opdateringer af undersøgelsesjournaler
Sidste opdatering sendt (Faktiske)
Sidste opdatering sendt
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidst verificeret
Sidst verificeret
Mere information
Begreber relateret til denne undersøgelse
Andre undersøgelses-id-numre
Andre undersøgelses-id-numre
- 2025P000986
Plan for individuelle deltagerdata (IPD)
Planlægger du at dele individuelle deltagerdata (IPD)?
Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter
Studerer et amerikansk FDA-reguleret lægemiddelprodukt
Studerer et amerikansk FDA-reguleret enhedsprodukt
produkt fremstillet i og eksporteret fra U.S.A.
Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .