Study of the Cell Response in the Tear Film After Overnight Contact Lens Wear (CORNWALL)
Polymorphonuclear Leukocyte Response During Overnight Lens Wear
Studienübersicht
Status
Status
Bedingungen
Bedingungen
Intervention / Behandlung
Intervention / Behandlung
Detaillierte Beschreibung
Studientyp
Studientyp
Einschreibung (Tatsächlich)
Einschreibung
Phase
Phase
- Unzutreffend
Kontakte und Standorte
Studienorte
-
-
Ontario
-
Waterloo, Ontario, Kanada, N2L 3G1
- University of Waterloo Centre for Contact Lens Research
-
-
Teilnahmekriterien
Zulassungskriterien
Zulassungskriterien
Studienberechtigtes Alter
Akzeptiert gesunde Freiwillige
Studienberechtigte Geschlechter
Beschreibung
Inclusion Criteria:
- 17 years of age or older.
- Ocular examination in the last two years.
- Has up-to-date spectacles.
Falls into one of the following three categories:
- Adapted wearer of Lotrafilcon A contact lenses
- Adapted wearer of Lotrafilcon B contact lenses
- Does not wear contact lenses
- Other protocol-defined inclusion criteria may apply.
Exclusion Criteria:
- Ocular disease
- Systemic or topical medications that may affect ocular health.
- Known sensitivity to diagnostic pharmaceuticals used in study.
- Uses artificial tears and/or rewetting drops.
- Wears contact lenses on an overnight basis for more than one night per week.
- Other protocol-defined exclusion criteria may apply.
Studienplan
Wie ist die Studie aufgebaut?
Designdetails
- Hauptzweck: Grundlegende Wissenschaft
- Zuteilung: Nicht randomisiert
- Interventionsmodell: Parallele Zuordnung
- Maskierung: Single
Anzahl der Arme
Waffen und Interventionen
Teilnehmergruppe / ArmTeilnehmergruppe / Arm |
Intervention / BehandlungIntervention / Behandlung |
|---|---|
|
Aktiver Komparator: Lotrafilcon A
Lotrafilcon A contact lenses worn on a daily wear basis for 1 week, followed by 8 hours overnight wear in a replacement pair.
After a 12-hour washout period, a new pair of lotrafilcon A contact lenses were dispensed for 4 weeks of daily wear, followed by 8 hours overnight wear.
|
Commercially marketed, silicone hydrogel, single-vision contact lens FDA-approved for daily and extended (overnight) wear for up to 30 nights.
Andere Namen:
Hydrogen peroxide-based contact lens care system for nightly cleaning and disinfection of study lenses
Andere Namen:
|
|
Aktiver Komparator: Lotrafilcon B
Lotrafilcon B contact lenses worn on a daily wear basis for 1 week, followed by 8 hours overnight wear in a replacement pair.
After a 12-hour washout period, a new pair of lotrafilcon B contact lenses were dispensed for 4 weeks of daily wear, followed by 8 hours overnight wear.
|
Hydrogen peroxide-based contact lens care system for nightly cleaning and disinfection of study lenses
Andere Namen:
Commercially marketed, silicone hydrogel, single-vision contact lens FDA-approved for daily or extended (overnight) wear up to 6 nights.
Andere Namen:
|
|
Kein Eingriff: No lens wear
No contact lens wear for the duration of the study.
One 8-hour sleep at 1 week, followed by an 8-hour sleep 4 weeks later.
|
Was misst die Studie?
Primäre Ergebnismessungen
Primäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Leukocyte Population
Zeitfenster: Week 5
|
A tear sample was collected after 8 hours of sleep using an ocular surface cell collection apparatus (OSCCA).
Different types of white blood cells (leukocytes) were identified, which included neutrophils, monocytes, and lymphocytes.
The total amount of leukocytes for contact lens wearers and non-lens wearers is presented.
Potential differences in leukocyte count between lens wearers and non-lens wearers may indicate a different immune response.
|
Week 5
|
|
Relative Cell Adhesion Response of Polymorphonuclear Leukocytes (PMNs)
Zeitfenster: Week 5
|
A tear sample was collected after 8 hours of sleep using an ocular surface cell collection apparatus (OSCCA) and analyzed on a flow cytometer.
CD54 is a protein typically found in the cell membrane of leukocytes, which up-regulates during inflammation and promotes cell adhesion.
Cell adhesion response is reported as a ratio of stimulated to non-stimulated samples.
|
Week 5
|
|
Relative Oxidative Response of Polymorphonuclear Leukocytes (PMNs)
Zeitfenster: Week 5
|
A tear sample was collected after 8 hours of sleep using an ocular surface cell collection apparatus (OSCCA) and analyzed on a flow cytometer.
Oxidative response is reported as a ratio of activated to non-activated samples.
DCF (dichlorofluorescein diacetate) is a molecular probe that measures the oxidative burst.
Upon stimulation, the PMNs synthesize reactive oxygen species, such as superoxide or hydrogen peroxide, which is detected by the probe.
Differences in the oxidative response between contact lens wearers and non-lens wearers is indicated by a shift in the ratio (stimulated/unstimulated).
|
Week 5
|
|
Change From Week 1 in Leukocyte Population at Week 5
Zeitfenster: Week 1, Week 5
|
A tear sample was collected after 8 hours of sleep using an ocular surface cell collection apparatus (OSCCA).
Different types of white blood cells (leukocytes) were identified, which included neutrophils, monocytes, and lymphocytes.
The difference between total leukocytes for contact lens wearers and non-lens wearers (Week 5 minus Week 1) is presented.
|
Week 1, Week 5
|
|
Change From 1 Week in Relative Cell Adhesion Response of PMNs at Week 5
Zeitfenster: Week 1, Week 5
|
A tear sample was collected after 8 hours of sleep using an ocular surface cell collection apparatus (OSCCA) and analyzed on a flow cytometer.
Cell adhesion response is reported as a ratio of activated to non-activated samples.
The difference between the ratio data for contact lens wearers and non-lens wearers (Week 5 minus Week 1) is presented.
|
Week 1, Week 5
|
|
Change From Week 1 in Relative Oxidative Response of PMNs at Week 5
Zeitfenster: Week 1, Week 5
|
A tear sample was collected after 8 hours of sleep using an ocular surface cell collection apparatus (OSCCA) and analyzed on a flow cytometer.
Oxidative response is reported as a ratio of activated to non-activated samples.
The difference between the ratio data for contact lens wearers and non-lens wearers (Week 5 minus Week 1) is presented.
|
Week 1, Week 5
|
Mitarbeiter und Ermittler
Sponsor
Sponsor
Mitarbeiter
Mitarbeiter
Ermittler
Ermittler
- Hauptermittler: Lyndon Jones, PhD FCOptom FAAO, Director, Centre for Contact Lens Research, School of Optometry, University of Waterloo
Studienaufzeichnungsdaten
Haupttermine studieren
Studienbeginn
Studienbeginn
Primärer Abschluss (Tatsächlich)
Primärer Abschluss
Studienabschluss (Tatsächlich)
Studienabschluss
Studienanmeldedaten
Zuerst eingereicht
Zuerst eingereicht
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst gepostet (Schätzen)
Zuerst gepostet
Studienaufzeichnungsaktualisierungen
Letztes Update gepostet (Schätzen)
Letztes Update gepostet
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Zuletzt verifiziert
Zuletzt verifiziert
Mehr Informationen
Begriffe im Zusammenhang mit dieser Studie
Andere Studien-ID-Nummern
Andere Studien-ID-Nummern
- P-373-C-102
Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .