Study of the Cell Response in the Tear Film After Overnight Contact Lens Wear (CORNWALL)
Polymorphonuclear Leukocyte Response During Overnight Lens Wear
Tutkimuksen yleiskatsaus
Tila
Tila
Ehdot
Ehdot
Interventio / Hoito
Interventio / Hoito
Yksityiskohtainen kuvaus
Opintotyyppi
Opintotyyppi
Ilmoittautuminen (Todellinen)
Ilmoittautuminen
Vaihe
Vaihe
- Ei sovellettavissa
Yhteystiedot ja paikat
Opiskelupaikat
-
-
Ontario
-
Waterloo, Ontario, Kanada, N2L 3G1
- University of Waterloo Centre for Contact Lens Research
-
-
Osallistumiskriteerit
Kelpoisuusvaatimukset
Kelpoisuusvaatimukset
Opintokelpoiset iät
Hyväksyy terveitä vapaaehtoisia
Sukupuolet, jotka voivat opiskella
Kuvaus
Inclusion Criteria:
- 17 years of age or older.
- Ocular examination in the last two years.
- Has up-to-date spectacles.
Falls into one of the following three categories:
- Adapted wearer of Lotrafilcon A contact lenses
- Adapted wearer of Lotrafilcon B contact lenses
- Does not wear contact lenses
- Other protocol-defined inclusion criteria may apply.
Exclusion Criteria:
- Ocular disease
- Systemic or topical medications that may affect ocular health.
- Known sensitivity to diagnostic pharmaceuticals used in study.
- Uses artificial tears and/or rewetting drops.
- Wears contact lenses on an overnight basis for more than one night per week.
- Other protocol-defined exclusion criteria may apply.
Opintosuunnitelma
Miten tutkimus on suunniteltu?
Suunnittelun yksityiskohdat
- Ensisijainen käyttötarkoitus: Perustiede
- Jako: Ei satunnaistettu
- Inventiomalli: Rinnakkaistehtävä
- Naamiointi: Yksittäinen
Aseiden lukumäärä
Aseet ja interventiot
Osallistujaryhmä / ArmOsallistujaryhmä / Arm |
Interventio / HoitoInterventio / Hoito |
|---|---|
|
Active Comparator: Lotrafilcon A
Lotrafilcon A contact lenses worn on a daily wear basis for 1 week, followed by 8 hours overnight wear in a replacement pair.
After a 12-hour washout period, a new pair of lotrafilcon A contact lenses were dispensed for 4 weeks of daily wear, followed by 8 hours overnight wear.
|
Commercially marketed, silicone hydrogel, single-vision contact lens FDA-approved for daily and extended (overnight) wear for up to 30 nights.
Muut nimet:
Hydrogen peroxide-based contact lens care system for nightly cleaning and disinfection of study lenses
Muut nimet:
|
|
Active Comparator: Lotrafilcon B
Lotrafilcon B contact lenses worn on a daily wear basis for 1 week, followed by 8 hours overnight wear in a replacement pair.
After a 12-hour washout period, a new pair of lotrafilcon B contact lenses were dispensed for 4 weeks of daily wear, followed by 8 hours overnight wear.
|
Hydrogen peroxide-based contact lens care system for nightly cleaning and disinfection of study lenses
Muut nimet:
Commercially marketed, silicone hydrogel, single-vision contact lens FDA-approved for daily or extended (overnight) wear up to 6 nights.
Muut nimet:
|
|
Ei väliintuloa: No lens wear
No contact lens wear for the duration of the study.
One 8-hour sleep at 1 week, followed by an 8-hour sleep 4 weeks later.
|
Mitä tutkimuksessa mitataan?
Ensisijaiset tulostoimenpiteet
Ensisijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
Leukocyte Population
Aikaikkuna: Week 5
|
A tear sample was collected after 8 hours of sleep using an ocular surface cell collection apparatus (OSCCA).
Different types of white blood cells (leukocytes) were identified, which included neutrophils, monocytes, and lymphocytes.
The total amount of leukocytes for contact lens wearers and non-lens wearers is presented.
Potential differences in leukocyte count between lens wearers and non-lens wearers may indicate a different immune response.
|
Week 5
|
|
Relative Cell Adhesion Response of Polymorphonuclear Leukocytes (PMNs)
Aikaikkuna: Week 5
|
A tear sample was collected after 8 hours of sleep using an ocular surface cell collection apparatus (OSCCA) and analyzed on a flow cytometer.
CD54 is a protein typically found in the cell membrane of leukocytes, which up-regulates during inflammation and promotes cell adhesion.
Cell adhesion response is reported as a ratio of stimulated to non-stimulated samples.
|
Week 5
|
|
Relative Oxidative Response of Polymorphonuclear Leukocytes (PMNs)
Aikaikkuna: Week 5
|
A tear sample was collected after 8 hours of sleep using an ocular surface cell collection apparatus (OSCCA) and analyzed on a flow cytometer.
Oxidative response is reported as a ratio of activated to non-activated samples.
DCF (dichlorofluorescein diacetate) is a molecular probe that measures the oxidative burst.
Upon stimulation, the PMNs synthesize reactive oxygen species, such as superoxide or hydrogen peroxide, which is detected by the probe.
Differences in the oxidative response between contact lens wearers and non-lens wearers is indicated by a shift in the ratio (stimulated/unstimulated).
|
Week 5
|
|
Change From Week 1 in Leukocyte Population at Week 5
Aikaikkuna: Week 1, Week 5
|
A tear sample was collected after 8 hours of sleep using an ocular surface cell collection apparatus (OSCCA).
Different types of white blood cells (leukocytes) were identified, which included neutrophils, monocytes, and lymphocytes.
The difference between total leukocytes for contact lens wearers and non-lens wearers (Week 5 minus Week 1) is presented.
|
Week 1, Week 5
|
|
Change From 1 Week in Relative Cell Adhesion Response of PMNs at Week 5
Aikaikkuna: Week 1, Week 5
|
A tear sample was collected after 8 hours of sleep using an ocular surface cell collection apparatus (OSCCA) and analyzed on a flow cytometer.
Cell adhesion response is reported as a ratio of activated to non-activated samples.
The difference between the ratio data for contact lens wearers and non-lens wearers (Week 5 minus Week 1) is presented.
|
Week 1, Week 5
|
|
Change From Week 1 in Relative Oxidative Response of PMNs at Week 5
Aikaikkuna: Week 1, Week 5
|
A tear sample was collected after 8 hours of sleep using an ocular surface cell collection apparatus (OSCCA) and analyzed on a flow cytometer.
Oxidative response is reported as a ratio of activated to non-activated samples.
The difference between the ratio data for contact lens wearers and non-lens wearers (Week 5 minus Week 1) is presented.
|
Week 1, Week 5
|
Yhteistyökumppanit ja tutkijat
Sponsori
Sponsori
Yhteistyökumppanit
Yhteistyökumppanit
Tutkijat
Tutkijat
- Päätutkija: Lyndon Jones, PhD FCOptom FAAO, Director, Centre for Contact Lens Research, School of Optometry, University of Waterloo
Opintojen ennätyspäivät
Opi tärkeimmät päivämäärät
Opiskelun aloitus
Opiskelun aloitus
Ensisijainen valmistuminen (Todellinen)
Ensisijainen valmistuminen
Opintojen valmistuminen (Todellinen)
Opintojen valmistuminen
Opintoihin ilmoittautumispäivät
Ensimmäinen lähetetty
Ensimmäinen lähetetty
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen Lähetetty (Arvio)
Ensimmäinen Lähetetty
Tutkimustietojen päivitykset
Viimeisin päivitys julkaistu (Arvio)
Viimeisin päivitys julkaistu
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeksi vahvistettu
Viimeksi vahvistettu
Lisää tietoa
Tähän tutkimukseen liittyvät termit
Muut tutkimustunnusnumerot
Muut tutkimustunnusnumerot
- P-373-C-102
Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .