Study of the Cell Response in the Tear Film After Overnight Contact Lens Wear (CORNWALL)
Polymorphonuclear Leukocyte Response During Overnight Lens Wear
Studieoversigt
Status
Status
Betingelser
Betingelser
Intervention / Behandling
Intervention / Behandling
Detaljeret beskrivelse
Undersøgelsestype
Undersøgelsestype
Tilmelding (Faktiske)
Tilmelding
Fase
Fase
- Ikke anvendelig
Kontakter og lokationer
Studiesteder
-
-
Ontario
-
Waterloo, Ontario, Canada, N2L 3G1
- University of Waterloo Centre for Contact Lens Research
-
-
Deltagelseskriterier
Berettigelseskriterier
Berettigelseskriterier
Aldre berettiget til at studere
Tager imod sunde frivillige
Køn, der er berettiget til at studere
Beskrivelse
Inclusion Criteria:
- 17 years of age or older.
- Ocular examination in the last two years.
- Has up-to-date spectacles.
Falls into one of the following three categories:
- Adapted wearer of Lotrafilcon A contact lenses
- Adapted wearer of Lotrafilcon B contact lenses
- Does not wear contact lenses
- Other protocol-defined inclusion criteria may apply.
Exclusion Criteria:
- Ocular disease
- Systemic or topical medications that may affect ocular health.
- Known sensitivity to diagnostic pharmaceuticals used in study.
- Uses artificial tears and/or rewetting drops.
- Wears contact lenses on an overnight basis for more than one night per week.
- Other protocol-defined exclusion criteria may apply.
Studieplan
Hvordan er undersøgelsen tilrettelagt?
Design detaljer
- Primært formål: Grundvidenskab
- Tildeling: Ikke-randomiseret
- Interventionel model: Parallel tildeling
- Maskning: Enkelt
Antal våben
Våben og indgreb
Deltagergruppe / ArmDeltagergruppe / Arm |
Intervention / BehandlingIntervention / Behandling |
|---|---|
|
Aktiv komparator: Lotrafilcon A
Lotrafilcon A contact lenses worn on a daily wear basis for 1 week, followed by 8 hours overnight wear in a replacement pair.
After a 12-hour washout period, a new pair of lotrafilcon A contact lenses were dispensed for 4 weeks of daily wear, followed by 8 hours overnight wear.
|
Commercially marketed, silicone hydrogel, single-vision contact lens FDA-approved for daily and extended (overnight) wear for up to 30 nights.
Andre navne:
Hydrogen peroxide-based contact lens care system for nightly cleaning and disinfection of study lenses
Andre navne:
|
|
Aktiv komparator: Lotrafilcon B
Lotrafilcon B contact lenses worn on a daily wear basis for 1 week, followed by 8 hours overnight wear in a replacement pair.
After a 12-hour washout period, a new pair of lotrafilcon B contact lenses were dispensed for 4 weeks of daily wear, followed by 8 hours overnight wear.
|
Hydrogen peroxide-based contact lens care system for nightly cleaning and disinfection of study lenses
Andre navne:
Commercially marketed, silicone hydrogel, single-vision contact lens FDA-approved for daily or extended (overnight) wear up to 6 nights.
Andre navne:
|
|
Ingen indgriben: No lens wear
No contact lens wear for the duration of the study.
One 8-hour sleep at 1 week, followed by an 8-hour sleep 4 weeks later.
|
Hvad måler undersøgelsen?
Primære resultatmål
Primære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Leukocyte Population
Tidsramme: Week 5
|
A tear sample was collected after 8 hours of sleep using an ocular surface cell collection apparatus (OSCCA).
Different types of white blood cells (leukocytes) were identified, which included neutrophils, monocytes, and lymphocytes.
The total amount of leukocytes for contact lens wearers and non-lens wearers is presented.
Potential differences in leukocyte count between lens wearers and non-lens wearers may indicate a different immune response.
|
Week 5
|
|
Relative Cell Adhesion Response of Polymorphonuclear Leukocytes (PMNs)
Tidsramme: Week 5
|
A tear sample was collected after 8 hours of sleep using an ocular surface cell collection apparatus (OSCCA) and analyzed on a flow cytometer.
CD54 is a protein typically found in the cell membrane of leukocytes, which up-regulates during inflammation and promotes cell adhesion.
Cell adhesion response is reported as a ratio of stimulated to non-stimulated samples.
|
Week 5
|
|
Relative Oxidative Response of Polymorphonuclear Leukocytes (PMNs)
Tidsramme: Week 5
|
A tear sample was collected after 8 hours of sleep using an ocular surface cell collection apparatus (OSCCA) and analyzed on a flow cytometer.
Oxidative response is reported as a ratio of activated to non-activated samples.
DCF (dichlorofluorescein diacetate) is a molecular probe that measures the oxidative burst.
Upon stimulation, the PMNs synthesize reactive oxygen species, such as superoxide or hydrogen peroxide, which is detected by the probe.
Differences in the oxidative response between contact lens wearers and non-lens wearers is indicated by a shift in the ratio (stimulated/unstimulated).
|
Week 5
|
|
Change From Week 1 in Leukocyte Population at Week 5
Tidsramme: Week 1, Week 5
|
A tear sample was collected after 8 hours of sleep using an ocular surface cell collection apparatus (OSCCA).
Different types of white blood cells (leukocytes) were identified, which included neutrophils, monocytes, and lymphocytes.
The difference between total leukocytes for contact lens wearers and non-lens wearers (Week 5 minus Week 1) is presented.
|
Week 1, Week 5
|
|
Change From 1 Week in Relative Cell Adhesion Response of PMNs at Week 5
Tidsramme: Week 1, Week 5
|
A tear sample was collected after 8 hours of sleep using an ocular surface cell collection apparatus (OSCCA) and analyzed on a flow cytometer.
Cell adhesion response is reported as a ratio of activated to non-activated samples.
The difference between the ratio data for contact lens wearers and non-lens wearers (Week 5 minus Week 1) is presented.
|
Week 1, Week 5
|
|
Change From Week 1 in Relative Oxidative Response of PMNs at Week 5
Tidsramme: Week 1, Week 5
|
A tear sample was collected after 8 hours of sleep using an ocular surface cell collection apparatus (OSCCA) and analyzed on a flow cytometer.
Oxidative response is reported as a ratio of activated to non-activated samples.
The difference between the ratio data for contact lens wearers and non-lens wearers (Week 5 minus Week 1) is presented.
|
Week 1, Week 5
|
Samarbejdspartnere og efterforskere
Sponsor
Sponsor
Samarbejdspartnere
Samarbejdspartnere
Efterforskere
Efterforskere
- Ledende efterforsker: Lyndon Jones, PhD FCOptom FAAO, Director, Centre for Contact Lens Research, School of Optometry, University of Waterloo
Datoer for undersøgelser
Studer store datoer
Studiestart
Studiestart
Primær færdiggørelse (Faktiske)
Primær færdiggørelse
Studieafslutning (Faktiske)
Studieafslutning
Datoer for studieregistrering
Først indsendt
Først indsendt
Først indsendt, der opfyldte QC-kriterier
Først indsendt, der opfyldte QC-kriterier
Først opslået (Skøn)
Først opslået
Opdateringer af undersøgelsesjournaler
Sidste opdatering sendt (Skøn)
Sidste opdatering sendt
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidst verificeret
Sidst verificeret
Mere information
Begreber relateret til denne undersøgelse
Andre undersøgelses-id-numre
Andre undersøgelses-id-numre
- P-373-C-102
Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .