- ICH GCP
- US-Register für klinische Studien
- Klinische Studie NCT06263842
Modifizierter Elamrousy-Ansatz für die sofortige Implantatinsertion mithilfe der Socket-Sheild-Technik
Periimplantäre klinische und radiologische Veränderungen nach sofort eingesetzten und sofort belasteten Zahnimplantaten unter Verwendung des Socket-Shield-Ansatzes mit autogenem Ganzzahntransplantat im Vergleich zu Xenotransplantat: Randomisierte klinische Studie
The current trial aim was to evaluate clinically and radiographically the changes around dental implants inserted immediately in maxillary anterior esthetic zone using a novel combination of autogenous whole tooth graft (AWTG) with socket shield approach (SSA) and compared this approach to socket shield technique with xenograft.
The present study included 63 patients, aged 20 to 45, with teeth that needed to be extracted. After Kafrelsheikh University research ethics committee approval, patients were randomized into 3 groups: group I patients underwent immediate implantation using socket shield protocol, while group II patients underwent the same procedure, but the shield/fixture jumping gap was grafted by xenograft. finally group III was grafted by AWTG that was created using the decoronated crown and the extracted palatal portion of the tooth; and then placed in the peri-implant gap defect.
Studienübersicht
Status
Bedingungen
Detaillierte Beschreibung
It has been demonstrated that utilizing dental implants to replace lost teeth is a predictable clinical choice. Promising outcomes of immediate implant insertion in conjunction with immediate loading/provisionalization (Type 1A implant protocol according to Gallucci et al has been reported to provide major benefits in terms of better esthetic and psychosocial impacts, shorter treatment duration, minimal surgical interventions and preservation of peri-implant bone and soft tissue.
However, because of technically sensitive and sophisticated surgery required for Type 1A protocol, high risk of early implant failure was noticed particularly in conditions that might complicate that protocol as deficient facial bone plate, soft tissues deficiencies and thin gingival phenotype. Furthermore, those conditions also were found to be responsible for midfacial mucosal recession (MFMR), papillary recession and resorption of facial plate that deteriorates the clinical, radiological, and esthetic outcomes of Type 1A protocol. Consequently, alternate approaches would be suggested to improve the clinical and esthetic concerns associated with immediate implantation and loading such as buccal gap grafting, guided bone regeneration and socket shield approach.
In order to maintain the facial bone plate for prompt Type 1A protocol in esthetic zone, the SSA has been developed by Hürzeler et al. in 2010 as a potential therapeutic approach through maintaining the facial portion of the root and thus preserving the periodontal ligament and its vascularity that nourishes the tooth's bundle bone. The FSS functions as a natural barrier that prevents buccal bone resorption and enhances tissue contouring, both of which contribute to the achievement of predictable esthetic outcomes. Additionally, the FSS serves as a guide to ensure the implant is positioned correctly. SSA in conjunction with immediate loading reduces the frequency of clinical sessions and reduces the necessity for both soft and hard tissue grafts.
It has been recommended to palatally insert the implants in extraction sockets with at least 2 mm jumping gap between the fixture and the FSS. Significantly, this gap denotes the future buccal bone that will directly contribute to the buccal contour and impact the soft tissue levels. For jumping gaps smaller than 2 mm, bone heals spontaneously, while gaps bigger than 2 mm are advised to be augmented.
AWTG is obviously very advantageous as it exhibits superior osteoconductive and osteoinductive capacity with high biocompatibility and comparable physico-chemical characteristics to autogenous bones. AWTG was successfully employed for augmenting of peri-implant bone defects, with excellent clinical and radiographic outcomes. Similarly, both AWTG and autogenous demineralized dentin graft were equally effective at reducing dimensional losses in alveolar ridge preservation. The production of demineralized dentin is time-consuming, cost-intensive and complicated, which restricts its widespread use in clinics.
In the light of this, the current study was conducted to assess and compare the effectiveness of AWTG versus xenograft for augmenting the FSS/fixture jumping gap around immediately placed implants using SSA with immediate temporization in the maxillary esthetic zone.
To the best of our knowledge, this study is the first to use AWTG for filling the peri-implant jumping gap following SSA and highlight its impact on peri-implant soft and hard tissue parameters compared to xenograft.
Studientyp
Einschreibung (Tatsächlich)
Phase
- Unzutreffend
Kontakte und Standorte
Studienorte
-
-
-
Kafr ash Shaykh, Ägypten, 76130
- Walid Elamrousy
-
-
Teilnahmekriterien
Zulassungskriterien
Studienberechtigtes Alter
Akzeptiert gesunde Freiwillige
Studienberechtigte Geschlechter
Beschreibung
Inclusion Criteria:
- above the age of 18years
- presence of non-restorable maxillary anterior tooth
- had sufficient bone volume and
- The primary stability at insertion not less than 35 N
Exclusion Criteria:
-
history of systemic condition
-
history of using bisphosphonates or other drugs that might impact bone turnover
-
a history of smoking during the previous five years,
-
a history of any acute infections at the surgical site,
-
teeth having root resorptions
-
massive periodontal destruction
, the presence of any systemic diseases;
-
intake of drugs that may alter bone metabolism
-
presence of acute infection
-
infra-bony horizontal tooth fracture
-
facial vertical root fracture;
-
root resorption; mobile teeth
-
malaligned teeth,
-
active periodontitis at the implantation site.
Studienplan
Wie ist die Studie aufgebaut?
Designdetails
- Hauptzweck: Behandlung
- Zuteilung: Zufällig
- Interventionsmodell: Parallele Zuordnung
- Maskierung: Single
Waffen und Interventionen
Teilnehmergruppe / Arm |
Intervention / Behandlung |
|---|---|
|
Experimental: Immediate Implant Placement Using Socket Shield Technique alone
after insertion of immediate implant Using Socket Shield Technique, the bone defect between the socket shield and the implant fixture will be left ungrafted |
the jumping gap will be left ungrafted |
|
Experimental: Immediate Implant Placement Using Socket Shield Technique with xenograft
the shield/fixture jumping gap will be grafted with xenograft |
the jumping gap will be filled with xenograft |
|
Experimental: Modified Elamrousy Approach for Immediate Implant Placement Using Socket Shield Technique
Immediate Implant Placement Using Socket Shield Technique with autogenous whole tooth graft after immediate implantation using Socket Shield Technique, the palatal root portion and the decoronated crown will be converted to autogenous whole tooth graft and used for grafting the defect between the socket shield and the implant fixture |
the jumping gap will be filled with AWTG |
Was misst die Studie?
Primäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Horizontal bone width
Zeitfenster: 24-month.
|
Measuring the buccolingual width of the ridge at the CBCT sagittal/axial section was carried out by calculating the distance between the outer boundaries of the palatal and facial bony plates horizontally at a distance of 2 mm away from the implant shoulder apically |
24-month.
|
|
Stability Quotient of dental implant (SQDI)
Zeitfenster: 24-month.
|
Osstell TM was used to record the primary stability.ISQ, or Implant Stability Quotient, is a scale from 1 to 100 and is a measure of the stability of an implant. The ISQ scale has a non-linear correlation to micro mobility. With more than 1400 scientific references, investigators now know that high stability means >70 ISQ, between 60-69 is medium stability and < 60 ISQ is considered as low stability. |
24-month.
|
|
pink esthetic score (PES)
Zeitfenster: 24-month.
|
The pink esthetic score (PES) evaluates the esthetic outcome of soft tissue around implant-supported single crowns in the anterior zone by awarding seven points for the mesial and distal papilla, soft-tissue level, soft-tissue contour, soft-tissue color, soft-tissue texture, and alveolar process deficiency.Using a 0-1-2 scoring system, 0 being the lowest, 2 being the highest value, the maximum achievable PES was 14 |
24-month.
|
|
Midfacial Mucosal Alterations
Zeitfenster: 24-month.
|
digital intraoral scans were recorded. To quantify the vertical changes in the soft tissues around implants buccally, the collected scans were digitally superimposed via matching Gom inspect software |
24-month.
|
Sekundäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
facial marginal bone level (FMBL)
Zeitfenster: 24-month.
|
Utilizing CBCT sagittal sections, the BMBL was evaluated by computerized analysis. Navigation was done on the multiplanar display until the implant's precise same-view location was established on the reformatted cross-sectional section and panoramic view. |
24-month.
|
Mitarbeiter und Ermittler
Sponsor
Ermittler
- Hauptermittler: Walid AH Elamrousy, PhD, Faculty of Oral and Dental Medicine, Kafrelsheikh University
Studienaufzeichnungsdaten
Haupttermine studieren
Studienbeginn (Tatsächlich)
Primärer Abschluss (Tatsächlich)
Studienabschluss (Tatsächlich)
Studienanmeldedaten
Zuerst eingereicht
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst gepostet (Tatsächlich)
Studienaufzeichnungsaktualisierungen
Letztes Update gepostet (Tatsächlich)
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Zuletzt verifiziert
Mehr Informationen
Begriffe im Zusammenhang mit dieser Studie
Zusätzliche relevante MeSH-Bedingungen
Andere Studien-ID-Nummern
- KFSIRB200-132
Plan für individuelle Teilnehmerdaten (IPD)
Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?
Beschreibung des IPD-Plans
IPD will not be shared with other researchers
Arzneimittel- und Geräteinformationen, Studienunterlagen
Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt
Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt
Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .