The Comparison of Two Different Methods of Partial Inflation of Cuff for Facile Insertion of Laryngeal Mask Airway in Pediatric Patients
Descripción general del estudio
Estado
Estado
Condiciones
Condiciones
Intervención / Tratamiento
Intervención / Tratamiento
Tipo de estudio
Tipo de estudio
Inscripción (Actual)
Inscripción
Fase
Fase
- No aplica
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
-
Seoul, Corea, república de, 120-752
- Severance Hospital
-
-
Criterios de participación
Criterio de elegibilidad
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Descripción
Inclusion Criteria:
- children (0-9 years of age)
- children who is scheduled for elective surgery of short duration (less than 2 hr) undergoing general anesthesia using LMA-classic
Exclusion Criteria:
- patients with an abnormal airway
- patients with reactive airway disease
- patients with gastroesophageal reflux disease
- patients with chronic respiratory disease
- patients who has a history of an upper respiratory tract infection in the preceding 6-week period
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Asignación: Aleatorizado
- Modelo Intervencionista: Asignación paralela
- Enmascaramiento: Doble
Número de brazos
Armas e Intervenciones
Grupo de participantes/brazoGrupo de participantes/brazo |
Intervención / TratamientoIntervención / Tratamiento |
|---|---|
|
Experimental: grupo de volumen en reposo
|
80 patients are randomly allocated into two groups : resting volume group (n=40), half the maximum volume group (n=40).
In the resting volume group, the pilot balloon valve is connected to syringe without piston for keeping the valve open to the atmosphere and allowing the pressure within the cuff of LMA to equalize with atmospheric pressure.
In the half the maximum volume group, the cuff of LMA is completely emptied and then the cuff is filled with the half the maximum volume.
|
|
Comparador activo: maximum volume group
|
80 patients are randomly allocated into two groups : resting volume group (n=40), half the maximum volume group (n=40).
In the resting volume group, the pilot balloon valve is connected to syringe without piston for keeping the valve open to the atmosphere and allowing the pressure within the cuff of LMA to equalize with atmospheric pressure.
In the half the maximum volume group, the cuff of LMA is completely emptied and then the cuff is filled with the half the maximum volume.
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
The intra-cuff pressure
Periodo de tiempo: approximately 5 to 10 minutes after insertion of LMA.
|
1) After insertion of LMA, we confirm adequate ventilation.
And then we measure intra-cuff pressure using cuff pressure manometer.
2) After confirming adequate ventilation, tidal volumes are measured using spirometer sensor attached anesthesia machine.
Five corresponding inspiratory and expiratory tidal volumes are recorded and the difference between these is calculated as the leak volume.
The time that measures the intra-cuff pressure and leak volume is approximately 5 to 10 minutes after insertion of LMA.
|
approximately 5 to 10 minutes after insertion of LMA.
|
|
The leak volume
Periodo de tiempo: approximately 5 to 10 minutes after insertion of LMA.
|
1) After insertion of LMA, we confirm adequate ventilation.
And then we measure intra-cuff pressure using cuff pressure manometer.
2) After confirming adequate ventilation, tidal volumes are measured using spirometer sensor attached anesthesia machine.
Five corresponding inspiratory and expiratory tidal volumes are recorded and the difference between these is calculated as the leak volume.
The time that measures the intra-cuff pressure and leak volume is approximately 5 to 10 minutes after insertion of LMA.
|
approximately 5 to 10 minutes after insertion of LMA.
|
Colaboradores e Investigadores
Patrocinador
Patrocinador
Publicaciones y enlaces útiles
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio
Inicio del estudio
Finalización primaria (Actual)
Finalización primaria
Finalización del estudio (Actual)
Finalización del estudio
Fechas de registro del estudio
Enviado por primera vez
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Estimar)
Publicado por primera vez
Actualizaciones de registros de estudio
Última actualización publicada (Estimar)
Última actualización publicada
Última actualización enviada que cumplió con los criterios de control de calidad
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Última verificación
Más información
Términos relacionados con este estudio
Otros números de identificación del estudio
Otros números de identificación del estudio
- 1-2011-0046
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
producto fabricado y exportado desde los EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .
Ensayos clínicos sobre The cuff inflation by the resting volume
-
NCT02234232TerminadoEnfermedad renal en etapa terminal