Esta página se tradujo automáticamente y no se garantiza la precisión de la traducción. por favor refiérase a versión inglesa para un texto fuente.

Viabilidad diagnóstica de la estimulación tetánica de 100 Hz

24 de noviembre de 2026 actualizado por: Pongrácz Adrienn, University of Debrecen

Diagnostic Feasibility of 100 Hz Tetanic Stimulation in the Perioperative Setting in Patients With Normal and Abnormal ENG: a Pilot Study

The goal of this observational study is to investigate the applicability of 100 Hz tetanic stimulation with an electromyography device in the exclusion of postoperative residual neuromuscular block. The aim is to determine whether fatigue develops with 100 Hz tetanic stimulation in anaesthetized, non-relaxed patients with normal or abnormal baseline electroneurographic (ENG) findings.

Descripción general del estudio

Estado

Terminado

Condiciones

Descripción detallada

The aim of the present study is to investigate the applicability of 100 Hz tetanic stimulation with an electromyography (EMG) device. The aim is to determine whether fatigue develops with 100 Hz tetanic stimulation in anaesthetized, non-relaxed patients with normal or abnormal baseline electroneurographic (ENG) findings. Electric responses of the musculus digiti minimi elicited by supramaximal stimulation of the ulnar nerve at the carpal tunnel are monitored. Alpine Biomed ENG-EMG device with Keypoint software version 5.11 is used for the examinations. The exposed arm is fixed on the armboard, the skin is degreased and then the electrodes for monitoring are mounted lege artis. After the anesthesia has been induced, ENG of the ulnar nerve is examined. Based on the results of the ENG test, patients are divided into separate groups (normal or abnormal ENG). During the ENG test, the supramaximal current is determined. Afterwards, repetitive tetanic stimulation of the defined frequency (60 and 100 Hz) and duration (5 sec) is applied to the two test groups at the current according to the test plan.

The clinical utilities of the study results are:

  • Determination of the "safety margin" of neuromuscular junction, which is not provided by routine monitoring.
  • To investigate how comorbid status (especially chronic conditions affecting peripheral nerves such as polyneuropathy) influences the feasibility of tetanic stimulation in the diagnostics of residual neuromuscular block and safety margin.

Tipo de estudio

De observación

Inscripción (Actual)

40

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Ubicaciones de estudio

      • Debrecen, Hungría, 4032
        • University of Debrecen Medical Center, Department of Anesthesiology and Intensive Care
    • Hajdú-Bihar
      • Debrecen, Hajdú-Bihar, Hungría, 4032
        • Department of Anesthesiology and Intensive Care, University of Debrecen

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

18 años a 65 años (Adulto, Adulto Mayor)

Acepta Voluntarios Saludables

Sí

Géneros elegibles para el estudio

Todos

Método de muestreo

Muestra no probabilística

Población de estudio

Surgical patients

Descripción

Inclusion Criteria:

  • ASA 1-3;
  • BMI 18.5-25 (normal body weight);
  • patient is in supine position with one arm accessible.

Exclusion Criteria:

  • diseases with impaired neuromuscular function (myopathies, severe liver and kidney failure);
  • drugs affecting neuromuscular function (magnesium, aminoglycosides);
  • pregnancy (pregnancy tests are carried out in women of childbearing age to rule out pregnancy);
  • breast-feeding;
  • acute surgery

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Modelos observacionales: COHORT
  • Perspectivas temporales: PROSPECTIVE

Cohortes e Intervenciones

Grupo / Cohorte
Normal ENG

Patients who have normal results at baseline electroneurogrphy examination

Abnormal ENG

Patients who have abnormal results at baseline electroneurogrphy examination due to polyneuropathy

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
100 Hz tetanic fade response of abductor digiti minimi muscle to ulnar nerve stimulation in patients with normal and abnormal ENG
Periodo de tiempo: From enrollment until end of anesthesia asessed up to 1 hour. No further ENG measurements are performed in the postoperative period.

Electroneurography response of the abductor digiti minimi muscle to 100 Hz tetanic stimulation (tetanic fade) is examined to find out if there is difference in patients with or without polyneuropathy. Tetanic fade is the decrease of the twitch heights of the compound muscle action potential due to depletion of cetylcholin stores in the nerve terminal during tetanic stimulation.

From enrollment until end of anesthesia asessed up to 1 hour. No further ENG measurements are performed in the postoperative period.

Medidas de resultado secundarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Diagnostic feasibility of electromyography in the examination of safety margin
Periodo de tiempo: From enrollment until end of anesthesia assessed up to 1 hour. No further ENG measurements are performed in the postoperative period.

To see whether tetanic stimulation with electromyography can be used as a routine tool to examine the safety margin and residual neuromuscular block. It is expected that there will be no fade in muscle response to 60 Hz tetanic stimulation in either groups. It is suspected that there will be no tetanic fade response to 100 Hz tetanic stimulation in patinets with normal ENG, however patinets with abnormal baseline ENG will produce tetanic fade. The incidence and extent of tetanic fade response will be examined.

From enrollment until end of anesthesia assessed up to 1 hour. No further ENG measurements are performed in the postoperative period.

Otras medidas de resultado

Medida de resultado
Medida Descripción
Periodo de tiempo
60 Hz tetanic fade response of abductor digiti minimi muscle to ulnar nerve stimulation in patients with normal and abnormal ENG
Periodo de tiempo: From enrollment until end of anesthesia assessed up to 1 hour. No further ENG measurements are performed in the postoperative period.

Electroneurography response of the abductor digiti minimi muscle to 60 Hz tetanic stimulation (tetanic fade) is examined to find out if there is difference in patients with or without polyneuropathy. Tetanic fade is the decrease of the twitch heights of the compound muscle action potential due to depletion of cetylcholin stores in the nerve terminal during tetanic stimulation.

From enrollment until end of anesthesia assessed up to 1 hour. No further ENG measurements are performed in the postoperative period.

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Patrocinador

Investigadores

  • Director de estudio: Béla Fülesdi, MD PhD DSci, University of Debrecen

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio (Actual)

6 de enero de 2025

Finalización primaria (Actual)

31 de octubre de 2026

Finalización del estudio (Actual)

31 de octubre de 2026

Fechas de registro del estudio

Enviado por primera vez

5 de diciembre de 2024

Primero enviado que cumplió con los criterios de control de calidad

23 de diciembre de 2024

Publicado por primera vez (Actual)

1 de enero de 2025

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

25 de noviembre de 2026

Última actualización enviada que cumplió con los criterios de control de calidad

24 de noviembre de 2026

Última verificación

1 de noviembre de 2026

Más información

Términos relacionados con este estudio

Otros números de identificación del estudio

  • AITT 2024/2

Plan de datos de participantes individuales (IPD)

¿Planea compartir datos de participantes individuales (IPD)?

NO

Información sobre medicamentos y dispositivos, documentos del estudio

Estudia un producto farmacéutico regulado por la FDA de EE. UU.

No

Estudia un producto de dispositivo regulado por la FDA de EE. UU.

No

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .