SLT directo versus convencional en glaucoma de ángulo abierto: un ECA
Un ensayo controlado aleatorio que compara la trabeculoplastia láser selectiva directa (DSLT) y la trabeculoplastia láser selectiva (SLT) para reducir la presión intraocular en glaucoma de ángulo abierto
This study compares two laser treatments for open-angle glaucoma: Selective Laser Trabeculoplasty (SLT) and Direct Selective Laser Trabeculoplasty (DSLT). SLT is a widely used procedure that requires a manual technique with a goniolens, while DSLT is a new, automated, non-contact method using the Eagle system. The study will evaluate whether DSLT is as effective as SLT in reducing intraocular pressure (IOP). Participants will be randomly assigned to receive either treatment and will be monitored over 12 months to assess changes in IOP, medication use, and safety outcomes. The goal is to determine if the simpler DSLT procedure can provide similar results to SLT, potentially improving patient comfort and access to glaucoma care.
Descripción general del estudio
Estado
Estado
Condiciones
Condiciones
Intervención / Tratamiento
Intervención / Tratamiento
Descripción detallada
Glaucoma management is fundamentally aimed at reducing intraocular pressure (IOP) to prevent optic nerve damage and preserve vision. Selective Laser Trabeculoplasty (SLT) has been a cornerstone in the treatment of open-angle glaucoma due to its efficacy and safety profile. However, SLT's manual delivery method using a goniolens can introduce variability, patient discomfort, and operator dependency.
Direct Selective Laser Trabeculoplasty (DSLT) represents an innovative advancement, offering a non-contact, automated laser treatment via the Eagle system. This technology is designed to simplify the procedure, enhance patient comfort, and minimize operator-induced variability. Early evidence suggests that DSLT may provide similar or improved IOP reduction compared to SLT, with a potentially better safety profile.
This study seeks to rigorously evaluate whether DSLT is non-inferior to SLT in reducing IOP, thus providing critical data on the efficacy and safety of this novel approach. Demonstrating non-inferiority would support broader adoption of DSLT, potentially improving patient outcomes and expanding access to effective glaucoma treatment.
Tipo de estudio
Tipo de estudio
Inscripción (Estimado)
Inscripción
Fase
Fase
- No aplica
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
South Carolina
-
Charleston, South Carolina, Estados Unidos, 29407
- MUSC Health West Ophthalmology Clinic
-
-
Criterios de participación
Criterio de elegibilidad
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Descripción
Inclusion Criteria:
-
Age ≥18 years.
-
Diagnosed with OAG (including exfoliative/pigmentary glaucoma) or OHT.
-
Gonioscopically visible scleral spur for 360 degrees.
-
Ability to provide informed consent.
-
In good health, without prior laser trabeculoplasty, with decision to treat made by an ophthalmologist on the basis of risk profile, patient preference, or both.
-
Each eye with one of the following qualifying diagnoses (diagnoses may differ between eyes):
- High-risk ocular hypertension (OHT): IOP > 21 mmHg without glaucomatous optic neuropathy (excavation, diffuse or focal thinning or notching of the neuroretinal rim, visible nerve fiber layer defects, or asymmetry of the vertical cup-to-disc ratio of >0.2 between eyes) [enrollment of trial participants with High-risk OHT will be capped at 25% of total enrollment]
- Mild primary open-angle glaucoma: glaucomatous optic neuropathy, visual field mean deviation >-6.0 dB with no points in the central 5° <15 dB
- Moderate primary open-angle glaucoma: glaucomatous optic neuropathy, visual field mean deviation -6.0 dB to >-12 dB and no more than 1 central 5° point <15 dB
Exclusion Criteria:
- Advanced POAG in either eye
- Glaucoma other than OAG (including pigmentary and pseudoexfoliation glaucoma) in either eye
- Mean IOP > 35 mmHg at either the screening or baseline visit in either eye
- Narrow or closed angle (Shaffer Grade 0, 1, or 2) in either eye
- Contraindications to SLT, brimonidine, apraclonidine, or any other study intervention
- Any corneal pathology that would preclude accurate assessment of IOP by Goldmann tonometry in either eye
- Any intraocular surgical procedure within the past 6 months in either eye
- Inability to attend all scheduled study visits
- Pregnancy or plan to become pregnant in the next 1 year
- Any prior laser trabeculoplasty, including ALT, MLT and SLT.
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Tratamiento
- Asignación: Aleatorizado
- Modelo Intervencionista: Asignación paralela
- Enmascaramiento: Único
Número de brazos
Armas e Intervenciones
Grupo de participantes/brazoGrupo de participantes/brazo |
Intervención / TratamientoIntervención / Tratamiento |
|---|---|
|
Otro: Arm 1- DSLT (Direct Selective Laser Trabeculoplasty)
DSLT is a well-established non-contact laser application that does not require a gonioscopy lens, reducing the risk of corneal damage and inflammation. |
This intervention aims to determine the efficacy and safety of Direct Selective Laser Trabeculoplasty (DSLT) in reducing intraocular pressure in patients with open-angle glaucoma. |
|
Otro: Arm 2- Selective Laser Trabeculoplasty (SLT)
SLT is a widely used and effective laser therapy to lower intraocular pressure that requires operator expertise and carries risks of mild inflammation, corneal damage and discomfort. This is a standard laser system that requires the use of a gonioscopy lens placed on the cornea to administer. |
To determine the efficacy and safety of using Selective Laser Trabeculoplasty for treatment of open-angle glaucoma. |
¿Qué mide el estudio?
Medidas de resultado primarias
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Primary Endpoint
Periodo de tiempo: 6 months
|
Measuring the difference in the average IOP measurement reduction from the patient's baseline at 6 months between the DSLT and the SLT groups. |
6 months
|
Medidas de resultado secundarias
Medidas de resultado secundarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Secondary Outcome
Periodo de tiempo: 12 months
|
The patients percentage of IOP reduction at 2 months, 6 months, and 12 months. Measuring the amount of patient's that have achieved >/= 20% IOP reduction at 6 months. Documentation of any change in the use of ocular hypotensive medications at 12 months. Documentation of the rate of repeat laser treatments or additional IOP lowering procedures. |
12 months
|
Colaboradores e Investigadores
Patrocinador
Patrocinador
Investigadores
Investigadores
- Investigador principal: Jella An, MD, MBA, Medical University of South Carolina
Publicaciones y enlaces útiles
Publicaciones Generales
- Konstantakopoulou E, Gazzard G, Garway-Heath D, Adeleke M, Ambler G, Vickerstaff V, Bunce C, Nathwani N, Barton K; LiGHT Trial Study Group. Selective Laser Trabeculoplasty After Medical Treatment for Glaucoma or Ocular Hypertension. JAMA Ophthalmol. 2025 Apr 1;143(4):295-302. doi: 10.1001/jamaophthalmol.2024.6492.
- Goldenfeld M, Belkin M, Dobkin-Bekman M, Sacks Z, Blum Meirovitch S, Geffen N, Leshno A, Skaat A. Automated Direct Selective Laser Trabeculoplasty: First Prospective Clinical Trial. Transl Vis Sci Technol. 2021 Mar 1;10(3):5. doi: 10.1167/tvst.10.3.5.
- Melik Parsadaniantz S, Reaux-le Goazigo A, Sapienza A, Habas C, Baudouin C. Glaucoma: A Degenerative Optic Neuropathy Related to Neuroinflammation? Cells. 2020 Feb 25;9(3):535. doi: 10.3390/cells9030535.
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Actual)
Inicio del estudio
Finalización primaria (Estimado)
Finalización primaria
Finalización del estudio (Estimado)
Finalización del estudio
Fechas de registro del estudio
Enviado por primera vez
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Publicado por primera vez
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización publicada
Última actualización enviada que cumplió con los criterios de control de calidad
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
Otros números de identificación del estudio
- Pro00142923
Plan de datos de participantes individuales (IPD)
¿Planea compartir datos de participantes individuales (IPD)?
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
producto fabricado y exportado desde los EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .