Esta página se tradujo automáticamente y no se garantiza la precisión de la traducción. por favor refiérase a versión inglesa para un texto fuente.

Seguridad y Rendimiento Clínico del Sistema de Andamio de Magnesio Reabsorbible Freesolve (RMS) en Sujetos con Lesiones de la Arteria Coronaria (BIOMAG-III)

10 de noviembre de 2026 actualizado por: Teleflex

Seguridad y Rendimiento Clínico del Sistema de Andamiaje Coronario de Magnesio Reabsorbible con Fármaco (Freesolve) en el Tratamiento de Pacientes con Lesiones de Novo en Arterias Coronarias Nativas

The objective of this study is to assess the safety and efficacy of the Freesolve resorbable magnesium scaffold (RMS) in the treatment of subjects with up to two de novo lesions in native coronary arteries compared to the Xience coronary drug-eluting stent (DES) system

Descripción general del estudio

Estado

Reclutamiento

Condiciones

Intervención / Tratamiento

Descripción detallada

The BIOMAG-III clinical trial is a prospective, international, multi-center, single-blinded, randomized controlled, non-inferiority trial to compare the Freesolve Sirolimus Eluting Coronary Resorbable Magnesium Scaffold (Freesolve RMS) System with the Xience Everolimus Eluting Stent (Xience DES) System. with respect to Target Lesion Failure (TLF) rate at 12 months. Subjects will be randomized in a 2:1 fashion Freesolve to Xience. A total of up to 1859 subjects will be randomized at up to 120 total sites worldwide including North America, Europe, and Asia Pacific. Clinical follow-up will be conducted at 1, 6, and 12 months and at 2, 3, 4, and 5 years post-procedure.

Tipo de estudio

Intervencionista

Inscripción (Estimado)

1859

Fase

  • No aplica

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Estudio Contacto

  • Nombre: BIOMAG-III Project Manager
  • Número de teléfono: 1-866-246-6990
  • Correo electrónico: biomag_us@teleflex.com

Ubicaciones de estudio

    • District of Columbia
      • Washington D.C., District of Columbia, Estados Unidos, 20010
        • Reclutamiento
        • MedStar Washington Hospital Center
    • Texas
      • Dallas, Texas, Estados Unidos, 75226
        • Reclutamiento
        • Baylor Scott & White The Heart Hospital - Dallas
      • Plano, Texas, Estados Unidos, 75093
        • Reclutamiento
        • The Heart Hospital Baylor Plano
    • West Virginia
      • Charleston, West Virginia, Estados Unidos, 25304
        • Reclutamiento
        • Charleston Area Medical Center
    • Gard
      • Nîmes, Gard, Francia, 30900
        • Reclutamiento
        • CHU de Nîmes
      • Riga, Letonia, LV-1002
        • Reclutamiento
        • Pauls Stradins Clinical University Hospital
    • Lower Silesian Voivodeship
      • Lubin, Lower Silesian Voivodeship, Polonia, 59-301
        • Reclutamiento
        • Miedziowe Centrum Zdrowia S.A.

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

18 años a 80 años (Adulto, Adulto Mayor)

Acepta Voluntarios Saludables

No

Géneros elegibles para el estudio

Todos

Descripción

Clinical Inclusion Criteria:

  1. Subject is ≥ 18 years and ≤ 80 years of age

  2. Subject has provided written informed consent as approved by the Ethics Committee / Institutional Review Board (IRB) of the respective clinical site prior to the study related procedures

  3. Subject is eligible for PCI according to the applicable guidelines

  4. Subject is an acceptable candidate for coronary artery bypass surgery

  5. Subjects with stable or unstable angina pectoris, documented silent ischemia/abnormal physiologic testing or hemodynamically stable non-ST elevation myocardial infarction (NSTEMI) patients without angiographic evidence of thrombus at target lesion

    Note: STEMI patients may be eligible for the study for treatment of selected non-culprit lesions, if:

    • Subject and target lesion(s) meet all inclusion and no exclusion criteria and consent occurs at least ≥ 72 hours after successful treatment of the culprit lesion(s) [lesion(s) causing the acute STEMI];
    • Subject is hemodynamically stable with documented declining cardiac biomarkers;
    • Target lesion(s) to be treated are not located in the culprit vessel(s) and are not culprit lesion(s)
  6. Subject is eligible for Dual Antiplatelet Therapy (DAPT) with aspirin plus either clopidogrel, prasugrel, ticagrelor or ticlopidine

  7. Documented left ventricular ejection fraction (LVEF) ≥ 30% within 6 months prior to or during the procedure (prior to randomization)

  8. Subject is willing and able to comply with protocol requirements, including completion of study visits for the duration of the study

Angiographic Inclusion Criteria:

  1. Subjects with a maximum of two single de novo target lesions each in separate native coronary arteries
  2. Target vessel must have a reference diameter between 2.5-4.2 mm by operator visual estimation, which may be assisted by Quantitative Coronary Angiography (QCA) / Intravascular Ultrasound (IVUS) / Optical Coherence Tomography (OCT)
  3. Target lesion(s) must be ≤ 36 mm in length by operator visual estimation, which may be assisted by QCA / IVUS / OCT, (or < 20 mm for target lesion(s) to be treated with a study device < 3.0 mm in diameter) and must be amenable to treatment with a single study device
  4. Target lesion stenosis ≥ 50% and < 100% by operator visual estimation, which may be assisted by QCA / IVUS / OCT. Target lesion stenosis < 70% by visual estimation, should have clinical justification for treatment as per local standards.
  5. Target lesion must have a Thrombolysis in Myocardial Infarction (TIMI) flow ≥ 1

Clinical Exclusion Criteria:

  1. Subject is pregnant and/or breastfeeding or intends to become pregnant during the duration of the study
  2. Subject has clinical symptoms and/or electrocardiogram (ECG) changes consistent with STEMI < 72 hours prior to the index procedure Note: Hemodynamically stable non-STEMI (NSTEMI) subjects are eligible for study enrollment
  3. Subject has undergone prior PCI within the target vessel during the last 12 months prior to the index procedure or prior PCI within a non-target vessel < 72 hours prior to the index procedure
  4. Subject is on dialysis or has impaired renal function (serum creatinine > 2.5 mg/dL or 221 µmol/L, determined within 7 days prior to the index procedure)
  5. Subject has a known allergy to contrast medium that cannot be adequately premedicated, or any known allergy to aspirin, P2Y12 inhibitors, both heparin and bivalirudin, sirolimus, everolimus (or similar limus drugs), poly L-lactide, the scaffold material (magnesium, aluminum, tantalum), or Xience stent material (cobalt, chromium, tungsten, nickel, methacrylic polymer, and fluoropolymer)
  6. Subject is receiving oral or intravenous immunosuppressive therapy (inhaled steroids are permitted) or has known life-limiting immunosuppressive or autoimmune disease (e.g., human immunodeficiency virus, systemic lupus erythematosus; diabetes mellitus is permitted)
  7. Life expectancy less than 1 year
  8. Planned surgery or dental surgical procedure within 6 months after index procedure, unless DAPT can be maintained
  9. In the investigator's opinion subject will not be able to comply with the follow-up requirements
  10. Subjects under oral anticoagulation therapy (OAC) prior to index procedure unless DAPT + OAC (i.e., triple therapy) can be maintained for a minimum of 1 month
  11. Subject has had a stroke or transient ischemic attack (TIA) within 6 months prior to the index procedure
  12. Subject with active bleeding disorder, active coagulopathy, or any other reason, who is ineligible for DAPT
  13. Subject is currently participating or plans to participate in another study with an investigational device or an investigational drug
  14. Subject has known severe aortic or mitral valve stenosis/insufficiency or has previously undergone transcatheter aortic valve replacement (TAVR)

Angiographic Exclusion Criteria:

  1. Target vessel has been previously treated and the target lesion is within 5 mm proximal or distal to the previously treated lesion
  2. Left main coronary artery disease
  3. Target lesion is totally occluded (100% stenosis)
  4. Thrombus in target vessel
  5. Future planned staged PCI either in target or non-target vessel
  6. Ostial target lesion within the left anterior descending (LAD), left circumflex (LCX), or right coronary artery (RCA) (within 5.0 mm of vessel origin)
  7. Target lesion involves a side branch ≥ 2.0 mm in diameter that requires a two-device strategy after pre-dilatation
  8. Target lesion is located in or supplied by an arterial or venous bypass graft
  9. Target lesion with excessive tortuosity proximal to or within the lesion based on visual estimation or heavily calcified target lesion which cannot be adequately pre-dilated by a non-compliant and/or cutting/scoring balloon as described in angiographic exclusion criteria 10
  10. Target lesion requires treatment with a device other than the non-compliant balloon and/or cutting/scoring balloon prior to scaffold/stent placement (including but not limited to atherectomy devices, intravascular lithotripsy, drug-coated balloons, etc.)
  11. Target vessel was treated with brachytherapy any time prior to the index procedure.
  12. Unsuccessful pre-dilatation, defined as residual stenosis > 20% (by visual estimation) and/or angiographic complications (e.g., distal embolization, side branch closure, flow-limiting dissections)

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Propósito principal: Tratamiento
  • Asignación: Aleatorizado
  • Modelo Intervencionista: Asignación paralela
  • Enmascaramiento: Único

Armas e Intervenciones

Grupo de participantes/brazo
Intervención / Tratamiento
Experimental: Freesolve RMS

Intervention with a Freesolve Sirolimus Eluting Coronary Resorbable Magnesium Scaffold (RMS) System

Freesolve Sirolimus-Eluting Coronary Resorbable Magnesium Scaffold (RMS) System, a drug-eluting balloon-expandable resorbable scaffold

Comparador activo: Xience DES

Intervention with a Xience Everolimus Eluting Stent System

Xience Everolimus Eluting Stent System

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Target Lesion Failure (TLF) rate at 12 months post-index procedure
Periodo de tiempo: 12 months

The primary endpoint is Target Lesion Failure (TLF) at 12 months, a composite of Cardiac Death, Target Vessel Q-wave or non-Q wave MI, or clinically driven target lesion revascularization (TLR).

12 months

Medidas de resultado secundarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Muerte cardíaca
Periodo de tiempo: 1, 6, 12 meses y 2, 3, 4 y 5 años después del procedimiento índice
1, 6, 12 meses y 2, 3, 4 y 5 años después del procedimiento índice
Muerte cardiovascular
Periodo de tiempo: 1, 6, 12 meses y 2, 3, 4 y 5 años después del procedimiento índice
1, 6, 12 meses y 2, 3, 4 y 5 años después del procedimiento índice
Mortalidad por todas las causas
Periodo de tiempo: 1, 6, 12 meses y 2, 3, 4 y 5 años después del procedimiento índice
1, 6, 12 meses y 2, 3, 4 y 5 años después del procedimiento índice
Infarto de miocardio del vaso diana de acuerdo con las definiciones del objetivo principal para infarto de miocardio periprocedimiento y no periprocedimiento
Periodo de tiempo: 1, 6, 12 meses y 2, 3, 4 y 5 años tras el procedimiento índice
1, 6, 12 meses y 2, 3, 4 y 5 años tras el procedimiento índice
Cualquier IAM (incluyendo territorio de vaso no diana)
Periodo de tiempo: 1, 6, 12 meses y 2, 3, 4 y 5 años después del procedimiento índice
1, 6, 12 meses y 2, 3, 4 y 5 años después del procedimiento índice
TLR clínicamente guiado
Periodo de tiempo: 1, 6, 12 meses y 2, 3, 4 y 5 años después del procedimiento índice
1, 6, 12 meses y 2, 3, 4 y 5 años después del procedimiento índice
TVR impulsado clínicamente
Periodo de tiempo: 1, 6, 12 meses y 2, 3, 4 y 5 años después del procedimiento índice
1, 6, 12 meses y 2, 3, 4 y 5 años después del procedimiento índice
Trombosis del andamio/stent (definida, definida/probable, probable) según los criterios del Consorcio de Investigación Académica (ARC-2) para trombosis aguda, subaguda, tardía, muy tardía y acumulativa del andamio/stent
Periodo de tiempo: 1, 6, 12 meses y 2, 3, 4 y 5 años después del procedimiento índice
1, 6, 12 meses y 2, 3, 4 y 5 años después del procedimiento índice
Procedure success
Periodo de tiempo: Hospital Discharge (6-24 hours post-index procedure)

Procedure success defined as achievement of < 30% final residual diameter stenosis [by Quantitative Coronary Angiography (QCA) or visual estimation] of the target lesion using the assigned study device only, without the occurrence of cardiac death, Q-wave or non-Q-wave MI, or repeat revascularization of the target lesion during the hospital stay

Hospital Discharge (6-24 hours post-index procedure)
Device Success
Periodo de tiempo: Hospital Discharge (6-24 hours post-index procedure)

Device Success defined as a final residual diameter stenosis of < 30% by QCA or visual estimation, using the assigned device only with

  • successful delivery of the device to the target lesion, and
  • appropriate device deployment, and
  • successful removal of the delivery system
Hospital Discharge (6-24 hours post-index procedure)
Target lesion failure (TLF)
Periodo de tiempo: Time Frame: 1, 6 months and 2, 3, 4 and 5 years post-index procedure

TLF is defined as a composite of Cardiac Death, Target Vessel Q-wave or non-Q-wave myocardial infarction (MI), or clinically driven Target Lesion Revascularization (TLR)

Time Frame: 1, 6 months and 2, 3, 4 and 5 years post-index procedure
Target Vessel Failure (TVF)
Periodo de tiempo: 1, 6, 12 months and 2, 3, 4 and 5 years post-index procedure

Target Vessel Failure (TVF), a composite of Cardiac Death, Target Vessel Q-wave or non-Q wave MI, or clinically driven Target Vessel Revascularization (TVR)

1, 6, 12 months and 2, 3, 4 and 5 years post-index procedure
Powered Secondary Endpoint 1: TLF from 1-5 Years
Periodo de tiempo: 1 to 5 years post-index procedure

A powered secondary endpoint of cumulative TLF rates between 1 and 5 years post-procedure will be evaluated.

1 to 5 years post-index procedure
Powered Secondary Endpoint 2: TLF at 12 Months in the Diabetic Population
Periodo de tiempo: 12 months post-index procedure

A powered secondary endpoint of TLF at 12 months in the diabetic population will be evaluated.

12 months post-index procedure

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Patrocinador

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio (Actual)

11 de junio de 2026

Finalización primaria (Estimado)

1 de junio de 2029

Finalización del estudio (Estimado)

1 de junio de 2033

Fechas de registro del estudio

Enviado por primera vez

20 de noviembre de 2025

Primero enviado que cumplió con los criterios de control de calidad

20 de noviembre de 2025

Publicado por primera vez (Actual)

2 de diciembre de 2025

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

12 de noviembre de 2026

Última actualización enviada que cumplió con los criterios de control de calidad

10 de noviembre de 2026

Última verificación

1 de noviembre de 2026

Más información

Términos relacionados con este estudio

Otros números de identificación del estudio

  • G230176

Plan de datos de participantes individuales (IPD)

¿Planea compartir datos de participantes individuales (IPD)?

NO

Descripción del plan IPD

No IPD sharing is planned at this time. This study evaluates an investigational device under an FDA IDE. The sponsor may consider sharing de-identified IPD under controlled access following completion of primary endpoint analysis and regulatory review. Summary results will be reported in scientific publications and public registries.

Información sobre medicamentos y dispositivos, documentos del estudio

Estudia un producto farmacéutico regulado por la FDA de EE. UU.

No

Estudia un producto de dispositivo regulado por la FDA de EE. UU.

Sí

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .