Development of a Clinical Decision Support System for Cataract Surgery Planning Using Swept Source Optical Biometry (CAT-OCT)
This single-center, observational, analytical, ambispective study aims to develop and internally validate a clinical decision support system for cataract surgery planning using swept-source optical coherence tomography (SS-OCT) integrated into the ARGOS optical biometer.
The study will evaluate the ability of preoperative crystalline lens tomographic patterns (Types I-III) to predict surgical complexity and the surgical approach required during cataract extraction. Additionally, it will assess whether SS-OCT-derived information provides incremental predictive value beyond conventional clinical assessment using the Lens Opacities Classification System III (LOCS III).
Clinical, biometric, and surgical data will be analyzed to determine the predictive performance, reproducibility, and technical feasibility of the proposed classification system. The ultimate goal is to establish an objective, noninvasive, and reproducible tool to support personalized surgical planning and preoperative risk stratification in cataract surgery.
Descripción general del estudio
Estado
Estado
Condiciones
Condiciones
Intervención / Tratamiento
Intervención / Tratamiento
Descripción detallada
Background and Rationale
Cataract remains a leading cause of visual impairment and preventable blindness worldwide. Although advances in surgical techniques and technology have improved cataract surgery outcomes, predicting surgical complexity and selecting the most appropriate surgical approach remain important clinical challenges. Currently, preoperative assessment relies primarily on clinical examination and subjective grading systems, such as the Lens Opacities Classification System III (LOCS III), which may exhibit interobserver variability.
Swept-source optical coherence tomography (SS-OCT), integrated into optical biometers such as ARGOS (Alcon Laboratories, Inc.), provides noninvasive, high-resolution images of the crystalline lens and biometric measurements. These images may reveal morphological characteristics associated with lens opacity, nuclear density, and surgical complexity.
This study proposes the development and internal validation of a clinical decision support system based on the identification of specific crystalline lens tomographic patterns to improve preoperative risk stratification and support cataract surgery planning.
Study Design and Population
This is a single-center, observational, analytical, ambispective study conducted at Clínica de Oftalmología de Cali, Colombia. The study will include patients older than 40 years undergoing crystalline lens extraction who have undergone preoperative optical biometry using the ARGOS device, including SS-OCT imaging of the crystalline lens.
The ambispective design will incorporate retrospectively identified surgical cases and prospectively included patients. Surgical management will follow routine clinical practice, without experimental treatment assignment or modification of the surgical technique by the investigators.
Patients undergoing combined cataract surgery with glaucoma, corneal, or retinal procedures, those with a history of significant ocular trauma affecting anterior segment anatomy, and patients with ocular conditions preventing reliable tomographic image acquisition will be excluded.
A reference group of patients with clear crystalline lenses who underwent ARGOS biometry for indications other than cataract will be used exclusively to characterize the Type I tomographic pattern. These individuals will not be included in the statistical analysis.
Preoperative Assessment and Tomographic Classification
Preoperative evaluation will include demographic characteristics, visual acuity, LOCS III cataract grading, relevant ocular comorbidities, and biometric parameters obtained using ARGOS.
Crystalline lens SS-OCT images will be classified according to three predefined tomographic patterns (Types I, II, and III), based on lens reflectivity, intralenticular signal distribution, and the morphological characteristics of the anterior and posterior lens peaks.
Images will be independently assessed by trained observers blinded to the surgical technique and intraoperative outcomes. Disagreements will be resolved through consensus or third-observer adjudication. Interobserver and intraobserver reproducibility will be evaluated.
Study Outcomes
The primary outcome will be the need for a complex surgical approach during cataract extraction, defined using prespecified objective criteria derived from surgical records and, when available, surgical recordings.
Secondary outcomes will include the specific surgical technique performed, conversion from the initially planned approach, phacoemulsification energy parameters, intraoperative complications, and technical feasibility of SS-OCT image acquisition and interpretation.
Statistical Analysis and Internal Validation
The predictive performance of the proposed tomographic classification will be assessed using sensitivity, specificity, positive and negative predictive values, likelihood ratios, and overall classification accuracy, with 95% confidence intervals.
Multivariable logistic regression will be used to evaluate the association between SS-OCT patterns and surgical complexity. A conventional clinical prediction model based on LOCS III and prespecified clinical variables will be compared with an expanded model incorporating the SS-OCT tomographic classification.
Model discrimination will be evaluated using the area under the receiver operating characteristic curve (AUC-ROC), while calibration will be assessed by comparing predicted and observed outcomes. Internal validation will be performed using bootstrap resampling.
Expected Clinical Relevance
The study seeks to determine whether SS-OCT-derived crystalline lens patterns can provide clinically useful information beyond conventional cataract grading. If validated, this classification could support more objective preoperative assessment, improve identification of surgically complex cases, and facilitate individualized cataract surgery planning using information already available from routine optical biometry.
The proposed system is intended to complement, rather than replace, clinical judgment. Further external validation will be required before its implementation in routine clinical practice.
Tipo de estudio
Tipo de estudio
Inscripción (Actual)
Inscripción
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
Valle del Cauca Department
-
Cali, Valle del Cauca Department, Colombia, 760036
- Clínica de Oftalmología de Cali
-
-
Criterios de participación
Criterio de elegibilidad
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Método de muestreo
Población de estudio
For the establishment of the reference group with clear crystalline lenses, patients who underwent optical biometry using the ARGOS device for indications other than cataract, such as myopia monitoring, will be included to characterize the Type I pattern. These patients were not included in the statistical analysis of the study.
The study population will consist of patients older than 40 years with an indication for crystalline lens extraction and preoperative biometry performed using ARGOS, including acquisition of SS-OCT images of the crystalline lens. Patients in whom both the preoperative tomographic pattern and the surgical outcome can be adequately determined will be eligible.
Descripción
Inclusion Criteria:
- Patients older than 40 years undergoing crystalline lens extraction surgery.
- Preoperative optical biometry performed using the ARGOS biometer, including swept-source optical coherence tomography (SS-OCT) imaging of the crystalline lens.
- Availability of sufficient preoperative tomographic information and surgical records to determine both the lenticular tomographic pattern and the surgical outcome.
Exclusion Criteria:
- Patients undergoing combined cataract surgery with glaucoma, corneal, or retinal procedures.
- Patients with a history of ocular trauma capable of significantly altering anterior segment anatomy.
- Patients with ocular conditions that prevent the acquisition of reliable tomographic images using swept-source optical coherence tomography (SS-OCT).
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Modelos observacionales: COHORT
- Perspectivas temporales: PROSPECTIVE
Número de grupos/cohortes
Cohortes e Intervenciones
Grupo / CohorteGrupo / Cohorte |
Intervención / TratamientoIntervención / Tratamiento |
|---|---|
|
Cataract Surgery Patients
Patients older than 40 years undergoing cataract surgery with preoperative swept-source optical coherence tomography (SS-OCT) imaging obtained using the ARGOS biometer. Lenticular tomographic patterns will be classified and evaluated for their ability to predict surgical complexity and the surgical approach required. |
Preoperative assessment of crystalline lens tomographic patterns using swept-source optical coherence tomography (SS-OCT) integrated into the ARGOS optical biometer. Images will be classified according to predefined lenticular patterns (Types I-III) to evaluate their predictive value for surgical complexity and surgical approach during cataract extraction.
Otros nombres:
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Predictive Performance of SS-OCT Lenticular Patterns for Surgical Complexity in Cataract Surgery
Periodo de tiempo: 6 months
|
Assessment of the ability of preoperative crystalline lens tomographic patterns (Types I-III), obtained using swept-source optical coherence tomography (SS-OCT) with the ARGOS biometer, to predict the need for a complex surgical approach during cataract extraction. Surgical complexity will be classified as conventional or complex according to predefined objective criteria derived from operative records. Predictive performance will be evaluated using sensitivity, specificity, positive and negative predictive values, likelihood ratios, and overall classification accuracy, with 95% confidence intervals. |
6 months
|
Medidas de resultado secundarias
Medidas de resultado secundarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Incremental Predictive Value of SS-OCT Compared With LOCS III
Periodo de tiempo: 6 months
|
Evaluation of the additional predictive value of SS-OCT lenticular patterns beyond conventional clinical assessment using LOCS III. Predictive models will be compared in terms of discrimination, measured by the area under the receiver operating characteristic curve (AUC-ROC), and calibration. |
6 months
|
|
Distribution of Surgical Techniques Across SS-OCT Lenticular Pattern Categories
Periodo de tiempo: 6 months
|
To determine the percentage of eyes undergoing each surgical technique within the preoperative lenticular pattern categories (I, II, and III), as classified using swept-source optical coherence tomography (SS-OCT) images obtained with the ARGOS optical biometer. Surgical techniques will be identified from operative records and categorized as phacoemulsification (divide and conquer, stop and chop, vertical chop, or horizontal chop), extracapsular cataract extraction, or manual small-incision cataract surgery (MSICS). The frequency distribution of surgical techniques will be compared across SS-OCT lenticular pattern categories using appropriate categorical statistical methods. |
6 months
|
|
Cumulative Dissipated Energy During Phacoemulsification Across SS-OCT Lenticular Pattern Categories
Periodo de tiempo: 6 months
|
To quantify cumulative dissipated energy (CDE) during cataract surgery performed using phacoemulsification and describe its distribution across preoperative SS-OCT lenticular pattern categories (I, II, and III). CDE will be obtained from the phacoemulsification system records and expressed in the units reported by the device. Differences in CDE across lenticular pattern categories will be evaluated using statistical methods appropriate to the observed distribution of the data. |
6 months
|
|
Interobserver and Intraobserver Reproducibility of SS-OCT Lenticular Pattern Classification
Periodo de tiempo: 6 months
|
Assessment of interobserver and intraobserver agreement in the classification of SS-OCT lenticular patterns (Types I-III), using percentage agreement and Cohen's kappa coefficient with 95% confidence intervals. |
6 months
|
|
Incidence of Intraoperative Complications
Periodo de tiempo: 6 months
|
Assessment of the occurrence of intraoperative complications during cataract surgery and their association with preoperative SS-OCT lenticular patterns. Complication frequencies will be reported according to tomographic pattern classification. |
6 months
|
Colaboradores e Investigadores
Patrocinador
Patrocinador
Publicaciones y enlaces útiles
Publicaciones Generales
- Day AC, Donachie PH, Sparrow JM, Johnston RL; Royal College of Ophthalmologists' National Ophthalmology Database. The Royal College of Ophthalmologists' National Ophthalmology Database study of cataract surgery: report 1, visual outcomes and complications. Eye (Lond). 2015 Apr;29(4):552-60. doi: 10.1038/eye.2015.3. Epub 2015 Feb 13.
- Chylack LT Jr, Wolfe JK, Singer DM, Leske MC, Bullimore MA, Bailey IL, Friend J, McCarthy D, Wu SY. The Lens Opacities Classification System III. The Longitudinal Study of Cataract Study Group. Arch Ophthalmol. 1993 Jun;111(6):831-6. doi: 10.1001/archopht.1993.01090060119035.
- GBD 2019 Blindness and Vision Impairment Collaborators; Vision Loss Expert Group of the Global Burden of Disease Study. Causes of blindness and vision impairment in 2020 and trends over 30 years, and prevalence of avoidable blindness in relation to VISION 2020: the Right to Sight: an analysis for the Global Burden of Disease Study. Lancet Glob Health. 2021 Feb;9(2):e144-e160. doi: 10.1016/S2214-109X(20)30489-7. Epub 2020 Dec 1.
- Reifeltshammer SA, Khalil H, Hoftberger T, Laubichler P, Pomberger L, Waser K, Bolz M, Hirnschall N. Evaluation of the crystalline lens diameter using swept-source optical coherence tomography. BMJ Open Ophthalmol. 2026 Aug 20;11(3):e002819. doi: 10.1136/bmjophth-2026-002819.
- Angmo D, Nongpiur ME, Sharma R, Sidhu T, Sihota R, Dada T. Clinical utility of anterior segment swept-source optical coherence tomography in glaucoma. Oman J Ophthalmol. 2016 Jan-Apr;9(1):3-10. doi: 10.4103/0974-620X.176093.
- Hung KC, Ho TC, Lin PJ. Refractive outcomes after cataract surgery using swept-source OCT biometry and image-guided toric IOL alignment: a prospective comparative study in normal versus long axial length eyes. Sci Rep. 2026 Mar 2;16(1):11566. doi: 10.1038/s41598-026-41920-6.
- Nguyen P, Chopra V. Applications of optical coherence tomography in cataract surgery. Curr Opin Ophthalmol. 2013 Jan;24(1):47-52. doi: 10.1097/ICU.0b013e32835aee7b.
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Actual)
Inicio del estudio
Finalización primaria (Actual)
Finalización primaria
Finalización del estudio (Actual)
Finalización del estudio
Fechas de registro del estudio
Enviado por primera vez
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Publicado por primera vez
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización publicada
Última actualización enviada que cumplió con los criterios de control de calidad
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
Otros números de identificación del estudio
- 2020001-01
- 2020001-01 (Otro identificador: Self-financed)
Plan de datos de participantes individuales (IPD)
¿Planea compartir datos de participantes individuales (IPD)?
Marco de tiempo para compartir IPD
In 6 months
Criterios de acceso compartido de IPD
Restricted access by request
Tipo de información de apoyo para compartir IPD
- PROTOCOLO DE ESTUDIO
- SAVIA
- RSC
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
producto fabricado y exportado desde los EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .