Esta página se tradujo automáticamente y no se garantiza la precisión de la traducción. por favor refiérase a versión inglesa para un texto fuente.

Performance of MicroTextured Dental Implants

26 de enero de 2017 actualizado por: Michael Reddy, DMD, University of Alabama at Birmingham

A Randomized Clinical Trial to Assess the Performance of MicroTextured Dental Implants With or Without a Machined Collar

The study will compare initial peri-implant bone healing and longitudinal osseointegration between a fully microtextured dental implant and an analogous implant with a smooth machined collar.

The investigators hypothesize the fully textured implant will result in less peri-implant crestal bone resorption than the implant with a machined collar.

Descripción general del estudio

Descripción detallada

Zimmer dental has developed a microtextured tapered screw-vent implant design with a titanium skin that has been grit-blasted with hydroxyapatite particles resulting in an overall roughened surface, which, when compared to an implant with a machined (smooth) collar (narrow band around the top of the device) surface is thought to increase the apposition of osseous tissue integration and to promote epithelial attachment to the implant device.

Tipo de estudio

Intervencionista

Inscripción (Actual)

68

Fase

  • No aplica

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Ubicaciones de estudio

    • Alabama
      • Birmingham, Alabama, Estados Unidos, 35294-0007
        • University of Alabama at Birmingham School of Dentistry

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

19 años y mayores (Adulto, Adulto Mayor)

Acepta Voluntarios Saludables

No

Géneros elegibles para el estudio

Todos

Descripción

Inclusion Criteria:

  1. Be a current registered University of Alabama at Birmingham (UAB)dental school patient
  2. Existence of one or more missing teeth scheduled to be replaced with dental implants
  3. Healthy enough to undergo proposed therapy without compromising existing health
  4. Able to consent for their own inclusion
  5. Able to read and understand the informed consent form
  6. Demonstrated willingness to comply with protocol requirements and timeline

Exclusion Criteria:

  1. Any health condition that in the opinion of the investigators may adversely affect bone healing
  2. Any medication that in the opinion of the investigators may adversely affect bone healing
  3. Any indication of an inability to make autonomous decisions
  4. Reported pregnancy at the time of enrollment -

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Propósito principal: Tratamiento
  • Asignación: Aleatorizado
  • Modelo Intervencionista: Asignación paralela
  • Enmascaramiento: Único

Armas e Intervenciones

Grupo de participantes/brazo
Intervención / Tratamiento
Experimental: Microtextured dental implant
Randomized for microtextured dental implant treatment
Microtextured dental implant treatment will include a surgically inserted device implanted into edentulous areas of the jaw where natural teeth have been lost and adequate bone exists.
Otros nombres:
  • Screw-vent dental implant
Comparador activo: Dental implant
Randomized dental implant treatment with machined-collar implants
Treatment with dental implants; implants with a machined collar will be surgically implanted into edentulous areas of the jaw where natural teeth have been lost and adequate bone exists.

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Change in Millimeters of Bone Loss Surrounding the Implant Device
Periodo de tiempo: Implant insertion, 12 months post-insertion
Using radiographic images and image-processing software, measurements of bone height at the mesial and distal of each implant will be captured in millimeters.
Implant insertion, 12 months post-insertion

Medidas de resultado secundarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Changes in Peri-implant Gingivitis Score
Periodo de tiempo: 1 year after placement
Measurement of changes in peri-implant gingivitis score [Loe and Silness gingival index (GI)] after implant restoration
1 year after placement
Millimeters of Periodontal Pocket Depth Surrounding the Dental Implant Device
Periodo de tiempo: 1 year after placement
Probing pocket depth (PD) is measured from the mucosal sulcus to the depth of the pocket attachment after implant restoration.
1 year after placement

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Colaboradores

Investigadores

  • Investigador principal: Nicolaas C. Geurs, DDS.MS, University of Alabama at Birmingham

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio

1 de mayo de 2011

Finalización primaria (Actual)

1 de junio de 2014

Finalización del estudio (Actual)

1 de octubre de 2015

Fechas de registro del estudio

Enviado por primera vez

13 de marzo de 2013

Primero enviado que cumplió con los criterios de control de calidad

26 de marzo de 2013

Publicado por primera vez (Estimar)

1 de abril de 2013

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

16 de marzo de 2017

Última actualización enviada que cumplió con los criterios de control de calidad

26 de enero de 2017

Última verificación

1 de enero de 2017

Más información

Términos relacionados con este estudio

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .

3
Suscribir