- ICH GCP
- Registro de ensayos clínicos de EE. UU.
- Ensayo clínico NCT04793893
Tratamiento de la refracción hipermetrópica residual en pacientes jóvenes después de LASIK mediante implante de lentículo corneal fresco humano con cirugía de sonrisa ReLEX (Relex-Smile)
Tratamiento de la refracción hipermetrópica residual en pacientes jóvenes después de LASIK mediante implante de lentículo corneal fresco humano mediante cirugía de sonrisa Relex
LASIK (laser-assisted in situ keratomileusis) is a type of refractive surgery for correction of myopia, hyperopia and astigmatism. Yet approximately 30% of operated patients have symptoms like glare, halos, dry eyes and especially residual hypermetrop refractive errors.
Residual hypermetrop refractive errors are difficult to treat surgically, the current treatment is Refractive Lens Implantation - risks are similar to those of cataract surgery (endophthalmitis, loss of accommodation, etc.)
Descripción general del estudio
Estado
Condiciones
Intervención / Tratamiento
Descripción detallada
The main problem at young patients post - LASIK after one year is residual refractive errors.
The method used in Eye Hospital is treatment with implantation of human fresh corneal lenticule (min. -1.50D) taken from myopic patients in post - LASIK patients with residual refractive error (min. +1.0D).
The flap of LASIK is lifted, cleaned and then the lenticule is gently inserted. The fresh myopic lenticule is implanted under the guidance of corneal topography in young patients with hypermetropic astigmatism residual refraction, according to the low K value. In cases where astigmatism is not present the lenticule is positioned in central position under the flap.
The flap of LASIK is not touched or lifted but using VisuMax femtosecond laser we created the stromal pocket with diameter 8.0 mm (1 mm larger than the optical zone of the donor lenticule) and cap thickness set to 140 μm from corneal surface and 4 mm superior incision. Hinge position flap was set at 90° angle 50° and width 4 mm, side cut angle 90°. The pocket was dissected using a blunt spatula washed with normal saline. The lenticule was held with lenticule forceps and gently inserted into the pocket through the 4 mm superior incision.
Tipo de estudio
Inscripción (Actual)
Fase
- No aplica
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
-
Pristina, Kosovo, 10000
- Eye Hospital Pristina
-
-
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Descripción
Inclusion Criteria:
- residual hypermetropic refraction,
- low visual acuity
Exclusion Criteria:
- active anterior segment pathology,
- glaucoma,
- retinae detachment,
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Tratamiento
- Asignación: N / A
- Modelo Intervencionista: Asignación de un solo grupo
- Enmascaramiento: Ninguno (etiqueta abierta)
Armas e Intervenciones
Grupo de participantes/brazo |
Intervención / Tratamiento |
|---|---|
|
Experimental: Treatment of residual hypermetropia refraction after LASIK
The main problem at young patients post - LASIK after one year is residual hypermetropic refractive errors (especially accommodation problem) The method used in Eye Hospital is treatment with implantation of human fresh corneal lenticule (min. -1.50D) taken from myopic patients in post - LASIK patients with residual hypermetropic refractive error (min. +1.0D). The flap of LASIk is lifted,cleaned and then the lenticule gently inserted.The lenticule was positioned according the K2 values when is astigmatism residual refractive error.In cases where is not astigmatism the lenticule was positioned in central position under the flap. |
With the ReLex Smile the optical zone (lenticule diameter) and cap diameter are 6.5 and 7.5 mm respectively. After dissection of both anterior and posterior planes, the lenticule is extracted through 120 degree superior 3.5 mm incision and marked with a sterile marker (ViscotMedster). This retrospective case series included 84 eyes of 42 patients (15 male, 27 female; mean age 32.9 ± 7.5 years, range 22-44 years) who underwent positive meniscus-shaped lenticule transplantation for correction of residual hyperopia and presbyopia following prior hyperopic LASIK between January 2017 and December 2018. Of these, 13 patients (31.0%) were aged ≥40 years with established presbyopia. Preoperative refractive error was +3.68 ± 1.32 D (range +1.00 to +6.00 D) with a mean cylinder of +1.36 ± 0.43 D (range +0.75 to +2.00 D). Mean preoperative central corneal thickness was 493.87 ± 34.04 µm (range 440-560 µm). |
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Increase of visual acuity
Periodo de tiempo: 12 months
|
Increase of visual acuity by reducing residual hypermetropy refractive errors using ReLex Smile (human fresh lenticule implantation) after LASIK. |
12 months
|
Colaboradores e Investigadores
Patrocinador
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Actual)
Finalización primaria (Actual)
Finalización del estudio (Estimado)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
- EPristinaHospital
Plan de datos de participantes individuales (IPD)
¿Planea compartir datos de participantes individuales (IPD)?
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .