Ultrasonografía en modo M para la identificación del catéter epidural y la confirmación de la posición correcta del catéter (ETEMERC)
Evaluación de la ecografía en modo M para la identificación y colocación correcta del catéter epidural en anestesia obstétrica
In France, 80% of women choose epidural analgesia for delivery and birth. The localization of the epidural space is classically achieved by loss of resistance to saline. This blind technique means the passage of the needle through the ligamentum flavum. However, epidural analgesia failure has been reported in 27-32% of cases.
Currently, lumbar neuraxial ultrasound has become a valuable tool facilitating the placement of an epidural catheter. Although lumbar neuraxial ultrasound has been the source of many studies, few have focused on its use to confirm the exact location of the epidural catheter in the epidural space.
In the Pediatric and Obstetric Anesthesia-Resuscitation Department of the Necker-Enfants Malades Hospital, pre procedural lumbar neuraxial ultrasound for epidural anesthesia is a regular practice.
The objective of this study is to evaluate the ability of M-mode (M-m) and color Doppler (cD) ultrasonography to identify the epidural catheter position for parturients in the delivery room.
Descripción general del estudio
Estado
Condiciones
Intervención / Tratamiento
Descripción detallada
In France, 80% of women choose epidural analgesia for delivery and birth. The localization of the epidural space is classically achieved by loss of resistance to saline. This blind technique means the passage of the needle through the ligamentum flavum. However, epidural analgesia failure has been reported in 27-32% of cases.
Currently, lumbar neuraxial ultrasound has become a valuable tool facilitating the placement of an epidural catheter. Although lumbar neuraxial ultrasound has been the source of many studies, few have focused on its use to confirm the exact location of the epidural catheter in the epidural space.
Indeed, only 2 retrospective studies have described this strategy on cohorts with small numbers of adult patients. One demonstrated in a mixed population the possible localization of the epidural analgesia catheter using color Doppler (cD) mode (67.5% of cases) and M-mode (M-m) ultrasonography (M-m) (75%). Only one study identified the position of the epidural catheter in the obstetric context due to the cD mode ; with a low rate of visualization (37.1% of cases).
In the Pediatric and Obstetric Anesthesia-Resuscitation Department of the Necker-Enfants Malades Hospital, pre procedural lumbar neuraxial ultrasound for epidural anesthesia is a regular practice.
The objective of this study is to evaluate the ability of the M-m and cD mode to identify proper catheter placement in parturients in the delivery room.
Tipo de estudio
Inscripción (Actual)
Fase
- No aplica
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
-
Paris, Francia, 75015
- Hôpital Necker-Enfants Malades
-
-
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Descripción
Inclusion Criteria:
- Adult women admitted to the delivery room for a vaginal delivery with an epidural analgesia.
- Written informed consent.
- French speaking patient.
Exclusion Criteria:
- Patient with a contraindication to neuraxial analgesia.
- Visual Analogue Scale score >7 at epidural analgesia pose.
- No health insurance.
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Cuidados de apoyo
- Asignación: N / A
- Modelo Intervencionista: Asignación de un solo grupo
- Enmascaramiento: Ninguno (etiqueta abierta)
Armas e Intervenciones
Grupo de participantes/brazo |
Intervención / Tratamiento |
|---|---|
|
Experimental: Parturients
Adult patients admitted to the delivery room of Necker-Enfants Malades hospital maternity with an epidural catheter. |
Research of the location of the epidural analgesia catheter using M-mode and color Doppler (cD) ultrasonography. |
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Success rate of epidural catheter localisation in M-mode (M-m) ultrasonography
Periodo de tiempo: Day 0
|
The location of the epidural catheter is based on the visualization of the "beach and sea" sign with injection of the analgesic solution through the epidural catheter into the epidural space. |
Day 0
|
Medidas de resultado secundarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Success rate of epidural catheter localisation in color Doppler (cD) ultrasonography
Periodo de tiempo: Day 0
|
The localization of the epidural catheter is based on the visualization of a blue and red mosaic with the injection of the analgesic solution through the epidural catheter in the epidural space. |
Day 0
|
|
Risk factors associated with location failure in M-m et cD mode
Periodo de tiempo: 14 months
|
Description of the risk factors associated with catheter localization failure using M-mode (M-m) and color Doppler (cD) mode. |
14 months
|
|
Best neuraxial ultrasound view to locate the epidural analgesia catheter with M-mode (M-m) and color Doppler (cD) mode
Periodo de tiempo: 14 months
|
Determine the best neuraxial ultrasound view to locate the epidural catheter with M-mode (M-m) and color Doppler (cD) mode. |
14 months
|
|
Evaluate the effectiveness of epidural analgesia when the catheter is considered in the epidural space by lumbar neuraxial ultrasound
Periodo de tiempo: Day 0
|
Evaluate the percentage of epidurals having had a symmetrical sensory level > D10 when the epidural catheter is considered in the epidural space by lumbar neuraxial ultrasound. The epidural analgesia rate with a sensory level >D10 is determined 30 min after epidural analgesia application thanks to a sensitive test. |
Day 0
|
|
Duration of neuraxial ultrasound's research to determine the localization of epidural analgesia catheter
Periodo de tiempo: Day 0
|
Evaluate the time required in minutes to confirm the correct positioning of the epidural analgesia catheter using M-m and cD mode. |
Day 0
|
|
Assess operator satisfaction with M-mode (M-m) and color Doppler (cD) to locate the epidural catheter
Periodo de tiempo: Day 0
|
Operator satisfaction score with M-mode (M-m) and color Doppler (cD) to locate the epidural analgesia catheter with a numerical scale from 0 to 10. |
Day 0
|
|
Evaluate the satisfaction of parturients in terms of comfort during the lumbar neuraxial ultrasound to identify the epidural catheter
Periodo de tiempo: Day 0
|
Evaluate the satisfaction of parturients in terms of comfort during the lumbar neuraxial ultrasound to identify the epidural catheter with a numerical scale from 0 to 10 |
Day 0
|
Colaboradores e Investigadores
Patrocinador
Colaboradores
Investigadores
- Director de estudio: Hawa Keita-Meyer, MD, PhD, Assistance Publique - Hôpitaux de Paris
- Investigador principal: Lauranne Ossé, Assistance Publique - Hôpitaux de Paris
Publicaciones y enlaces útiles
Publicaciones Generales
- Perlas A, Chaparro LE, Chin KJ. Lumbar Neuraxial Ultrasound for Spinal and Epidural Anesthesia: A Systematic Review and Meta-Analysis. Reg Anesth Pain Med. 2016 Mar-Apr;41(2):251-60. doi: 10.1097/AAP.0000000000000184.
- Vanhaesebrouck A, Vilain A, Rey S, Fresson J. Les maternités en 2016: résultats de l'enquête nationale périnatale (ENP). Revue d'Épidémiologie et de Santé Publique. 2018;66:S54
- Sicard JA, Forestier J. Radiographic method for exploration of the extradural space using lipidol. Rev Neurol. 1921;28:1264
- Elsharkawy H, Sonny A, Govindarajan SR, Chan V. Use of colour Doppler and M-mode ultrasonography to confirm the location of an epidural catheter - a retrospective case series. Can J Anaesth. 2017 May;64(5):489-496. doi: 10.1007/s12630-017-0819-y. Epub 2017 Jan 10.
- Riveros-Perez E, Albo C, Jimenez E, Cheriyan T, Rocuts A. Color your epidural: color flow Doppler to confirm labor epidural needle position. Minerva Anestesiol. 2019 Apr;85(4):376-383. doi: 10.23736/S0375-9393.18.13175-0. Epub 2018 Nov 22.
- Osse L, Myriam B, Dahan S, Xavier R, Saumtally H, Orliaguet G, Bouvet L, Keita H. Performance of M-mode and Color Doppler Ultrasound for Confirming Epidural Catheter Placement in Laboring women: A Prospective Cohort Study. Anaesth Crit Care Pain Med. 2026 Apr 14:101850. doi: 10.1016/j.accpm.2026.101850. Online ahead of print.
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Actual)
Finalización primaria (Actual)
Finalización del estudio (Actual)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Otros números de identificación del estudio
- APHP230314
- 2023-A00076-39 (Otro identificador: IDRCB Number)
Plan de datos de participantes individuales (IPD)
¿Planea compartir datos de participantes individuales (IPD)?
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .