Ultrassonografia em modo M para identificação do cateter peridural e confirmação da posição correta do cateter (ETEMERC)
Avaliação da Ultrassonografia Modo-M para Identificação e Posicionamento Correto do Cateter Peridural em Anestesia Obstétrica
In France, 80% of women choose epidural analgesia for delivery and birth. The localization of the epidural space is classically achieved by loss of resistance to saline. This blind technique means the passage of the needle through the ligamentum flavum. However, epidural analgesia failure has been reported in 27-32% of cases.
Currently, lumbar neuraxial ultrasound has become a valuable tool facilitating the placement of an epidural catheter. Although lumbar neuraxial ultrasound has been the source of many studies, few have focused on its use to confirm the exact location of the epidural catheter in the epidural space.
In the Pediatric and Obstetric Anesthesia-Resuscitation Department of the Necker-Enfants Malades Hospital, pre procedural lumbar neuraxial ultrasound for epidural anesthesia is a regular practice.
The objective of this study is to evaluate the ability of M-mode (M-m) and color Doppler (cD) ultrasonography to identify the epidural catheter position for parturients in the delivery room.
Visão geral do estudo
Status
Intervenção / Tratamento
Descrição detalhada
In France, 80% of women choose epidural analgesia for delivery and birth. The localization of the epidural space is classically achieved by loss of resistance to saline. This blind technique means the passage of the needle through the ligamentum flavum. However, epidural analgesia failure has been reported in 27-32% of cases.
Currently, lumbar neuraxial ultrasound has become a valuable tool facilitating the placement of an epidural catheter. Although lumbar neuraxial ultrasound has been the source of many studies, few have focused on its use to confirm the exact location of the epidural catheter in the epidural space.
Indeed, only 2 retrospective studies have described this strategy on cohorts with small numbers of adult patients. One demonstrated in a mixed population the possible localization of the epidural analgesia catheter using color Doppler (cD) mode (67.5% of cases) and M-mode (M-m) ultrasonography (M-m) (75%). Only one study identified the position of the epidural catheter in the obstetric context due to the cD mode ; with a low rate of visualization (37.1% of cases).
In the Pediatric and Obstetric Anesthesia-Resuscitation Department of the Necker-Enfants Malades Hospital, pre procedural lumbar neuraxial ultrasound for epidural anesthesia is a regular practice.
The objective of this study is to evaluate the ability of the M-m and cD mode to identify proper catheter placement in parturients in the delivery room.
Tipo de estudo
Inscrição (Real)
Estágio
- Não aplicável
Contactos e Locais
Locais de estudo
-
-
-
Paris, França, 75015
- Hôpital Necker-Enfants Malades
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Descrição
Inclusion Criteria:
- Adult women admitted to the delivery room for a vaginal delivery with an epidural analgesia.
- Written informed consent.
- French speaking patient.
Exclusion Criteria:
- Patient with a contraindication to neuraxial analgesia.
- Visual Analogue Scale score >7 at epidural analgesia pose.
- No health insurance.
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Cuidados de suporte
- Alocação: N / D
- Modelo Intervencional: Atribuição de grupo único
- Mascaramento: Nenhum (rótulo aberto)
Armas e Intervenções
Grupo de Participantes / Braço |
Intervenção / Tratamento |
|---|---|
|
Experimental: Parturients
Adult patients admitted to the delivery room of Necker-Enfants Malades hospital maternity with an epidural catheter. |
Research of the location of the epidural analgesia catheter using M-mode and color Doppler (cD) ultrasonography. |
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Success rate of epidural catheter localisation in M-mode (M-m) ultrasonography
Prazo: Day 0
|
The location of the epidural catheter is based on the visualization of the "beach and sea" sign with injection of the analgesic solution through the epidural catheter into the epidural space. |
Day 0
|
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Success rate of epidural catheter localisation in color Doppler (cD) ultrasonography
Prazo: Day 0
|
The localization of the epidural catheter is based on the visualization of a blue and red mosaic with the injection of the analgesic solution through the epidural catheter in the epidural space. |
Day 0
|
|
Risk factors associated with location failure in M-m et cD mode
Prazo: 14 months
|
Description of the risk factors associated with catheter localization failure using M-mode (M-m) and color Doppler (cD) mode. |
14 months
|
|
Best neuraxial ultrasound view to locate the epidural analgesia catheter with M-mode (M-m) and color Doppler (cD) mode
Prazo: 14 months
|
Determine the best neuraxial ultrasound view to locate the epidural catheter with M-mode (M-m) and color Doppler (cD) mode. |
14 months
|
|
Evaluate the effectiveness of epidural analgesia when the catheter is considered in the epidural space by lumbar neuraxial ultrasound
Prazo: Day 0
|
Evaluate the percentage of epidurals having had a symmetrical sensory level > D10 when the epidural catheter is considered in the epidural space by lumbar neuraxial ultrasound. The epidural analgesia rate with a sensory level >D10 is determined 30 min after epidural analgesia application thanks to a sensitive test. |
Day 0
|
|
Duration of neuraxial ultrasound's research to determine the localization of epidural analgesia catheter
Prazo: Day 0
|
Evaluate the time required in minutes to confirm the correct positioning of the epidural analgesia catheter using M-m and cD mode. |
Day 0
|
|
Assess operator satisfaction with M-mode (M-m) and color Doppler (cD) to locate the epidural catheter
Prazo: Day 0
|
Operator satisfaction score with M-mode (M-m) and color Doppler (cD) to locate the epidural analgesia catheter with a numerical scale from 0 to 10. |
Day 0
|
|
Evaluate the satisfaction of parturients in terms of comfort during the lumbar neuraxial ultrasound to identify the epidural catheter
Prazo: Day 0
|
Evaluate the satisfaction of parturients in terms of comfort during the lumbar neuraxial ultrasound to identify the epidural catheter with a numerical scale from 0 to 10 |
Day 0
|
Colaboradores e Investigadores
Patrocinador
Colaboradores
Investigadores
- Diretor de estudo: Hawa Keita-Meyer, MD, PhD, Assistance Publique - Hôpitaux de Paris
- Investigador principal: Lauranne Ossé, Assistance Publique - Hôpitaux de Paris
Publicações e links úteis
Publicações Gerais
- Perlas A, Chaparro LE, Chin KJ. Lumbar Neuraxial Ultrasound for Spinal and Epidural Anesthesia: A Systematic Review and Meta-Analysis. Reg Anesth Pain Med. 2016 Mar-Apr;41(2):251-60. doi: 10.1097/AAP.0000000000000184.
- Vanhaesebrouck A, Vilain A, Rey S, Fresson J. Les maternités en 2016: résultats de l'enquête nationale périnatale (ENP). Revue d'Épidémiologie et de Santé Publique. 2018;66:S54
- Sicard JA, Forestier J. Radiographic method for exploration of the extradural space using lipidol. Rev Neurol. 1921;28:1264
- Elsharkawy H, Sonny A, Govindarajan SR, Chan V. Use of colour Doppler and M-mode ultrasonography to confirm the location of an epidural catheter - a retrospective case series. Can J Anaesth. 2017 May;64(5):489-496. doi: 10.1007/s12630-017-0819-y. Epub 2017 Jan 10.
- Riveros-Perez E, Albo C, Jimenez E, Cheriyan T, Rocuts A. Color your epidural: color flow Doppler to confirm labor epidural needle position. Minerva Anestesiol. 2019 Apr;85(4):376-383. doi: 10.23736/S0375-9393.18.13175-0. Epub 2018 Nov 22.
- Osse L, Myriam B, Dahan S, Xavier R, Saumtally H, Orliaguet G, Bouvet L, Keita H. Performance of M-mode and Color Doppler Ultrasound for Confirming Epidural Catheter Placement in Laboring women: A Prospective Cohort Study. Anaesth Crit Care Pain Med. 2026 Apr 14:101850. doi: 10.1016/j.accpm.2026.101850. Online ahead of print.
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Real)
Conclusão Primária (Real)
Conclusão do estudo (Real)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Outros números de identificação do estudo
- APHP230314
- 2023-A00076-39 (Outro identificador: IDRCB Number)
Plano para dados de participantes individuais (IPD)
Planeja compartilhar dados de participantes individuais (IPD)?
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .