Ultrassonografia em modo M para identificação do cateter peridural e confirmação da posição correta do cateter (ETEMERC)

17 de setembro de 2026 atualizado por: Assistance Publique - Hôpitaux de Paris

Avaliação da Ultrassonografia Modo-M para Identificação e Posicionamento Correto do Cateter Peridural em Anestesia Obstétrica

In France, 80% of women choose epidural analgesia for delivery and birth. The localization of the epidural space is classically achieved by loss of resistance to saline. This blind technique means the passage of the needle through the ligamentum flavum. However, epidural analgesia failure has been reported in 27-32% of cases.

Currently, lumbar neuraxial ultrasound has become a valuable tool facilitating the placement of an epidural catheter. Although lumbar neuraxial ultrasound has been the source of many studies, few have focused on its use to confirm the exact location of the epidural catheter in the epidural space.

In the Pediatric and Obstetric Anesthesia-Resuscitation Department of the Necker-Enfants Malades Hospital, pre procedural lumbar neuraxial ultrasound for epidural anesthesia is a regular practice.

The objective of this study is to evaluate the ability of M-mode (M-m) and color Doppler (cD) ultrasonography to identify the epidural catheter position for parturients in the delivery room.

Visão geral do estudo

Descrição detalhada

In France, 80% of women choose epidural analgesia for delivery and birth. The localization of the epidural space is classically achieved by loss of resistance to saline. This blind technique means the passage of the needle through the ligamentum flavum. However, epidural analgesia failure has been reported in 27-32% of cases.

Currently, lumbar neuraxial ultrasound has become a valuable tool facilitating the placement of an epidural catheter. Although lumbar neuraxial ultrasound has been the source of many studies, few have focused on its use to confirm the exact location of the epidural catheter in the epidural space.

Indeed, only 2 retrospective studies have described this strategy on cohorts with small numbers of adult patients. One demonstrated in a mixed population the possible localization of the epidural analgesia catheter using color Doppler (cD) mode (67.5% of cases) and M-mode (M-m) ultrasonography (M-m) (75%). Only one study identified the position of the epidural catheter in the obstetric context due to the cD mode ; with a low rate of visualization (37.1% of cases).

In the Pediatric and Obstetric Anesthesia-Resuscitation Department of the Necker-Enfants Malades Hospital, pre procedural lumbar neuraxial ultrasound for epidural anesthesia is a regular practice.

The objective of this study is to evaluate the ability of the M-m and cD mode to identify proper catheter placement in parturients in the delivery room.

Tipo de estudo

Intervencional

Inscrição (Real)

100

Estágio

  • Não aplicável

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Locais de estudo

      • Paris, França, 75015
        • Hôpital Necker-Enfants Malades

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

18 anos e mais velhos (Adulto, Adulto mais velho)

Aceita Voluntários Saudáveis

Não

Gêneros Elegíveis para o Estudo

Fêmea

Descrição

Inclusion Criteria:

  • Adult women admitted to the delivery room for a vaginal delivery with an epidural analgesia.
  • Written informed consent.
  • French speaking patient.

Exclusion Criteria:

  • Patient with a contraindication to neuraxial analgesia.
  • Visual Analogue Scale score >7 at epidural analgesia pose.
  • No health insurance.

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

  • Finalidade Principal: Cuidados de suporte
  • Alocação: N / D
  • Modelo Intervencional: Atribuição de grupo único
  • Mascaramento: Nenhum (rótulo aberto)

Armas e Intervenções

Grupo de Participantes / Braço
Intervenção / Tratamento
Experimental: Parturients

Adult patients admitted to the delivery room of Necker-Enfants Malades hospital maternity with an epidural catheter.

Research of the location of the epidural analgesia catheter using M-mode and color Doppler (cD) ultrasonography.

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
Success rate of epidural catheter localisation in M-mode (M-m) ultrasonography
Prazo: Day 0

The location of the epidural catheter is based on the visualization of the "beach and sea" sign with injection of the analgesic solution through the epidural catheter into the epidural space.

Day 0

Medidas de resultados secundários

Medida de resultado
Descrição da medida
Prazo
Success rate of epidural catheter localisation in color Doppler (cD) ultrasonography
Prazo: Day 0

The localization of the epidural catheter is based on the visualization of a blue and red mosaic with the injection of the analgesic solution through the epidural catheter in the epidural space.

Day 0
Risk factors associated with location failure in M-m et cD mode
Prazo: 14 months

Description of the risk factors associated with catheter localization failure using M-mode (M-m) and color Doppler (cD) mode.

14 months
Best neuraxial ultrasound view to locate the epidural analgesia catheter with M-mode (M-m) and color Doppler (cD) mode
Prazo: 14 months

Determine the best neuraxial ultrasound view to locate the epidural catheter with M-mode (M-m) and color Doppler (cD) mode.

14 months
Evaluate the effectiveness of epidural analgesia when the catheter is considered in the epidural space by lumbar neuraxial ultrasound
Prazo: Day 0

Evaluate the percentage of epidurals having had a symmetrical sensory level > D10 when the epidural catheter is considered in the epidural space by lumbar neuraxial ultrasound.

The epidural analgesia rate with a sensory level >D10 is determined 30 min after epidural analgesia application thanks to a sensitive test.

Day 0
Duration of neuraxial ultrasound's research to determine the localization of epidural analgesia catheter
Prazo: Day 0

Evaluate the time required in minutes to confirm the correct positioning of the epidural analgesia catheter using M-m and cD mode.

Day 0
Assess operator satisfaction with M-mode (M-m) and color Doppler (cD) to locate the epidural catheter
Prazo: Day 0

Operator satisfaction score with M-mode (M-m) and color Doppler (cD) to locate the epidural analgesia catheter with a numerical scale from 0 to 10.

Day 0
Evaluate the satisfaction of parturients in terms of comfort during the lumbar neuraxial ultrasound to identify the epidural catheter
Prazo: Day 0

Evaluate the satisfaction of parturients in terms of comfort during the lumbar neuraxial ultrasound to identify the epidural catheter with a numerical scale from 0 to 10

Day 0

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Investigadores

  • Diretor de estudo: Hawa Keita-Meyer, MD, PhD, Assistance Publique - Hôpitaux de Paris
  • Investigador principal: Lauranne Ossé, Assistance Publique - Hôpitaux de Paris

Publicações e links úteis

A pessoa responsável por inserir informações sobre o estudo fornece voluntariamente essas publicações. Estes podem ser sobre qualquer coisa relacionada ao estudo.

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Real)

9 de setembro de 2023

Conclusão Primária (Real)

26 de maio de 2024

Conclusão do estudo (Real)

26 de maio de 2024

Datas de inscrição no estudo

Enviado pela primeira vez

11 de maio de 2023

Enviado pela primeira vez que atendeu aos critérios de CQ

1 de junho de 2023

Primeira postagem (Real)

9 de junho de 2023

Atualizações de registro de estudo

Última Atualização Postada (Real)

22 de setembro de 2026

Última atualização enviada que atendeu aos critérios de controle de qualidade

17 de setembro de 2026

Última verificação

1 de setembro de 2025

Mais Informações

Termos relacionados a este estudo

Outros números de identificação do estudo

  • APHP230314
  • 2023-A00076-39 (Outro identificador: IDRCB Number)

Plano para dados de participantes individuais (IPD)

Planeja compartilhar dados de participantes individuais (IPD)?

NÃO

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Não

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .

Se inscrever