- ICH GCP
- Registro de ensayos clínicos de EE. UU.
- Ensayo clínico NCT06690333
Eficacia y seguridad de los marcapasos sin cables frente a la estimulación del área del haz izquierdo: una exploración preliminar (COMPAREPACE)
This is a prospective, randomized controlled (1:1) multicenter trial. The pilot study will be conducted up to three clinical sites in the United States. The primary purpose of this study is to compare the overall safety and efficacy between the leadless pacemaker and left bundle area pacing.
Descripción general del estudio
Estado
Condiciones
Intervención / Tratamiento
Descripción detallada
This is a prospective, randomized controlled (1:1) multicenter trial. The pilot study will be conducted up to three clinical sites in the United States. This study is designed to compare the safety and effectiveness of two types of pacemaker treatments: leadless pacemakers and left bundle area pacing. Patients who's heart rhythm indicate a degree of heart block that slows the heart beat and decreases the amount of blood the heart is pumping to the rest of the body will be identified by physicians to participate. This study seeks to improve our understanding of heart rhythm disorders to allow us to provide the best treatment for our patients.
Tipo de estudio
Inscripción (Estimado)
Fase
- No aplica
Contactos y Ubicaciones
Estudio Contacto
- Nombre: Dinesh Sharma, MD
- Número de teléfono: (239) 624-8113
- Correo electrónico: dinesh.sharma@nchmd.org
Copia de seguridad de contactos de estudio
- Nombre: Kathy Byrd, RN
- Número de teléfono: (239)624-8113
- Correo electrónico: Kathy.Byrd@nchmd.org
Ubicaciones de estudio
-
-
Florida
-
Naples, Florida, Estados Unidos, 34102
- Reclutamiento
- NCH Healthcare
-
Contacto:
- Kathy Byrd, RN
- Número de teléfono: (239)624-8113
- Correo electrónico: Kathy.Byrd@nchmd.org
-
-
Massachusetts
-
Boston, Massachusetts, Estados Unidos, 02114
- Reclutamiento
- Massachusetts General Hospital
-
Contacto:
- Christopher Azzam, BS
- Número de teléfono: 781-775-1214
- Correo electrónico: cazzam@mgh.harvard.edu
-
Investigador principal:
- Chee Ng, M.D.
-
-
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Descripción
Inclusion Criteria:
-
Age > 18
-
Planned for:
- permanent pacemaker implantation for AV node disease (first, second or third degree), OR
- post-TAVR patient requiring permanent pacemaker implantation
-
Preserved ejection fraction > 50%
-
Preserved sinus node function
-
Willingness to adhere to study restrictions and comply with all post-procedural follow-up requirements
-
Life expectancy > 1 year
-
Female subject of childbearing potential is not pregnant, not breast feeding, does not plan to be pregnant during the course of the study, and agrees to use a highly effective contraceptive method (i.e. IUD, birth control, vasectomized partner, sexual abstinence, etc.) during the course of the study.
-
Subject has been informed of the nature of the study, agrees to its provision and has provided written informed consent, approved by the IRB
Exclusion Criteria:
-
Sinus node dysfunction, anticipating atrial pacing or persistent atrial fibrillation
-
Anatomical restriction for either MICRA or transvenous pacing such as
- Access vein occlusion or thrombosis
- previous radiation therapy at insertion site
- inferior vena cava filter
-
Endstage renal disease (ESRD)/on dialysis
-
Dementia (inability to give consent)
-
Moderate to Severe or Severe Tricuspid valve regurgitation
-
Moderate to Severe or Severe Mitral valve regurgitation
-
History of mitral or tricuspid valve surgery
-
Preexisting implanted pacemaker or ICD or lead
-
Subject is allergic to titanium
-
Life expectancy < 1 year
-
Recurrent or high risk of infections
-
Active malignancy requiring systemic chemotherapy or local chest radiation
-
Subject has myocardial infarction, unstable angina, cerebrovascular accident, or heart failure admission within 3 months of the baseline visit
-
CABG, valve surgery or PCI within the last 3 months except TAVR
-
Other major cardiac surgery within the last 6 months
-
Persistent and permanent atrial fibrillation diagnosed by a healthcare provider
-
NYHA class 3 or 4 Heart Failure
Additional post-TAVR Exclusion Criteria:
-
Evidence of renal injury (12 hours post-TAVR)
-
Access site complication(s) post-TAVR
-
Suspicion of stroke/cerebrovascular accident (CVA) or transient ischemic attack (TIA) within 12 hours post-TAVR
-
Physician suspicion that ambulation to pre-TAVR activities post-pacemaker implantation would be unattainable
-
Other post-TAVR complications that in the opinion of the investigator may seriously confound study outcomes
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Otro
- Asignación: Aleatorizado
- Modelo Intervencionista: Asignación paralela
- Enmascaramiento: Único
Armas e Intervenciones
Grupo de participantes/brazo |
Intervención / Tratamiento |
|---|---|
|
Comparador activo: Left bundle area pacing
Transvenous pacemaker with left bundle area pacing |
Transvenous pacemaker with left bundle area pacing Transcatheter pacemaker with MICRA AV |
|
Comparador activo: MICRA AV
Transcatheter pacemaker with MICRA AV |
Transvenous pacemaker with left bundle area pacing Transcatheter pacemaker with MICRA AV |
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Efficacy & Safety
Periodo de tiempo: 12 months
|
The composite of:
|
12 months
|
Medidas de resultado secundarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Procedure time
Periodo de tiempo: from procedure start to procedure end
|
measured in minutes |
from procedure start to procedure end
|
|
Device longevity
Periodo de tiempo: at 12 month follow up
|
device longevity as noted on interrogation reports |
at 12 month follow up
|
Colaboradores e Investigadores
Colaboradores
Investigadores
- Investigador principal: Dinesh Sharma, MD, NCH Healthcare
Publicaciones y enlaces útiles
Publicaciones Generales
- Vijayaraman P, Ponnusamy S, Cano O, Sharma PS, Naperkowski A, Subsposh FA, Moskal P, Bednarek A, Dal Forno AR, Young W, Nanda S, Beer D, Herweg B, Jastrzebski M. Left Bundle Branch Area Pacing for Cardiac Resynchronization Therapy: Results From the International LBBAP Collaborative Study Group. JACC Clin Electrophysiol. 2021 Feb;7(2):135-147. doi: 10.1016/j.jacep.2020.08.015. Epub 2020 Oct 28.
- Kiehl EL, Makki T, Kumar R, Gumber D, Kwon DH, Rickard JW, Kanj M, Wazni OM, Saliba WI, Varma N, Wilkoff BL, Cantillon DJ. Incidence and predictors of right ventricular pacing-induced cardiomyopathy in patients with complete atrioventricular block and preserved left ventricular systolic function. Heart Rhythm. 2016 Dec;13(12):2272-2278. doi: 10.1016/j.hrthm.2016.09.027.
- Udo EO, Zuithoff NP, van Hemel NM, de Cock CC, Hendriks T, Doevendans PA, Moons KG. Incidence and predictors of short- and long-term complications in pacemaker therapy: the FOLLOWPACE study. Heart Rhythm. 2012 May;9(5):728-35. doi: 10.1016/j.hrthm.2011.12.014. Epub 2011 Dec 17.
- Vijayaraman P, Sharma PS, Cano O, Ponnusamy SS, Herweg B, Zanon F, Jastrzebski M, Zou J, Chelu MG, Vernooy K, Whinnett ZI, Nair GM, Molina-Lerma M, Curila K, Zalavadia D, Haseeb A, Dye C, Vipparthy SC, Brunetti R, Moskal P, Ross A, van Stipdonk A, George J, Qadeer YK, Mumtaz M, Kolominsky J, Zahra SA, Golian M, Marcantoni L, Subzposh FA, Ellenbogen KA. Comparison of Left Bundle Branch Area Pacing and Biventricular Pacing in Candidates for Resynchronization Therapy. J Am Coll Cardiol. 2023 Jul 18;82(3):228-241. doi: 10.1016/j.jacc.2023.05.006. Epub 2023 May 21.
- Chinitz L, Ritter P, Khelae SK, Iacopino S, Garweg C, Grazia-Bongiorni M, Neuzil P, Johansen JB, Mont L, Gonzalez E, Sagi V, Duray GZ, Clementy N, Sheldon T, Splett V, Stromberg K, Wood N, Steinwender C. Accelerometer-based atrioventricular synchronous pacing with a ventricular leadless pacemaker: Results from the Micra atrioventricular feasibility studies. Heart Rhythm. 2018 Sep;15(9):1363-1371. doi: 10.1016/j.hrthm.2018.05.004. Epub 2018 May 11.
- Sanchez R, Nadkarni A, Buck B, Daoud G, Koppert T, Okabe T, Houmsse M, Weiss R, Augostini R, Hummel JD, Kalbfleisch S, Daoud EG, Afzal MR. Incidence of pacing-induced cardiomyopathy in pacemaker-dependent patients is lower with leadless pacemakers compared to transvenous pacemakers. J Cardiovasc Electrophysiol. 2021 Feb;32(2):477-483. doi: 10.1111/jce.14814. Epub 2020 Nov 25.
- Duray GZ, Ritter P, El-Chami M, Narasimhan C, Omar R, Tolosana JM, Zhang S, Soejima K, Steinwender C, Rapallini L, Cicic A, Fagan DH, Liu S, Reynolds D; Micra Transcatheter Pacing Study Group. Long-term performance of a transcatheter pacing system: 12-Month results from the Micra Transcatheter Pacing Study. Heart Rhythm. 2017 May;14(5):702-709. doi: 10.1016/j.hrthm.2017.01.035. Epub 2017 Feb 10.
- Zhang S, Guo J, Tao A, Zhang B, Bao Z, Zhang G. Clinical outcomes of left bundle branch pacing compared to right ventricular apical pacing in patients with atrioventricular block. Clin Cardiol. 2021 Apr;44(4):481-487. doi: 10.1002/clc.23513. Epub 2021 Mar 11.
- Kusumoto FM, Schoenfeld MH, Barrett C, Edgerton JR, Ellenbogen KA, Gold MR, Goldschlager NF, Hamilton RM, Joglar JA, Kim RJ, Lee R, Marine JE, McLeod CJ, Oken KR, Patton KK, Pellegrini CN, Selzman KA, Thompson A, Varosy PD. 2018 ACC/AHA/HRS Guideline on the Evaluation and Management of Patients With Bradycardia and Cardiac Conduction Delay: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines and the Heart Rhythm Society. Circulation. 2019 Aug 20;140(8):e382-e482. doi: 10.1161/CIR.0000000000000628. Epub 2018 Nov 6. No abstract available.
- Huang HD, Mansour M. Pacemaker Implantation After Transcatheter Aortic Valve Replacement: A Necessary Evil Perhaps But Are We Making Progress? J Am Heart Assoc. 2020 May 5;9(9):e016700. doi: 10.1161/JAHA.120.016700. Epub 2020 May 2. No abstract available.
- Dell'Era G, Baroni M, Frontera A, Ghiglieno C, Carbonaro M, Penela D, Romano C, Giordano F, Del Monaco G, Galimberti P, Mazzone P, Patti G. Left bundle branch area versus conventional pacing after transcatheter valve implant for aortic stenosis: the LATVIA study. J Cardiovasc Med (Hagerstown). 2024 Jun 1;25(6):450-456. doi: 10.2459/JCM.0000000000001619. Epub 2024 Apr 1.
- Kassab K, Patel J, Feseha H, Kaynak E. MICRA AV implantation after transcatheter aortic valve replacement. Cardiovasc Revasc Med. 2024 Jun;63:31-35. doi: 10.1016/j.carrev.2024.01.005. Epub 2024 Jan 12.
- Mechulan A, Prevot S, Peret A, Nait-Saidi L, Miliani I, Leong-Feng L, Leude-Vaillant E, Vaillant A, Cornen A, Latiere B, Giacomoni MP, Collet F, Bechet V, Bouharaoua A, Dieuzaide P. Micra AV leadless pacemaker implantation after transcatheter aortic valve implantation. Pacing Clin Electrophysiol. 2022 Nov;45(11):1310-1315. doi: 10.1111/pace.14545. Epub 2022 Jun 13.
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Actual)
Finalización primaria (Estimado)
Finalización del estudio (Estimado)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Otros números de identificación del estudio
- IRB0081
- 13500 (Otro identificador: Medtronic)
Plan de datos de participantes individuales (IPD)
¿Planea compartir datos de participantes individuales (IPD)?
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
producto fabricado y exportado desde los EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .