Hypoglycaemia and Cardiac Arrhythmias in Type 2 Diabetes (HYPO-HEART)
Aperçu de l'étude
Statut
Statut
Les conditions
Les conditions
Intervention / Traitement
Intervention / Traitement
Type d'étude
Type d'étude
Inscription (Réel)
Inscription
Contacts et emplacements
Lieux d'étude
-
-
-
Hellerup, Danemark, 2900
- Gentofte Hospital
-
-
Critères de participation
Critère d'éligibilité
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
Méthode d'échantillonnage
Population étudiée
La description
Inclusion Criteria:
Patients with type 2 diabetes
- Informed and written consent
- Type 2 diabetes diagnosed according to the criteria of the World Health Organization (WHO)
- Treatment with insulin
- Glycated haemoglobin A1c (HbA1c) ≤58 mmol/mol
- One or more clinical relevant complications to diabetes defined as: peripheral neuropathy with vibration perception threshold of > 25 volt determined by biothesiometry, moderate to severe retinopathy, nephropathy (creatinine >130 μmol/l and/or albuminuria), and/or macrovascular disease. Macrovascular disease is defined as coronary disease (stable angina pectoris or previous unstable angina pectoris or myocardial infarct), cerebrovascular disease (previous stroke or transitional cerebral ischaemia), and peripheral vascular disease (previous intermittent claudication or prior acute ischemia)
- Well-functioning LR during run-in period (acceptable readings judged by an arrhythmologist)
- Participation in the extended study
Healthy individuals
- HbA1c ≤42 mmol/mol
- Fasting plasma glucose ≤6.1 mmol/l
Exclusion Criteria:
Patients with type 2 diabetes
- Arrhythmia diagnosed prior to or at the time of inclusion
- Implantable cardioverter defibrillator (ICD) or pacemaker at the time of inclusion
- Severe heart failure (left ventricular ejection fraction <25%)
- Structural heart disease (Wolf-Parkinson-White syndrome, congenital heart disease, severe valve disease)
- Insulin naïve patients with type 2 diabetes
- Thyroid dysfunction (except for well-regulated eltroxine substituted myxoedema)
- Unable to comply with daily CGM during run-in period
- Anemia (male: hemoglobin < 8.0; female: hemoglobin < 7.0 mmol/l)
Healthy individuals
- Type 1 or type 2 diabetes
- Prediabetes (HbA1c >42 mmol/l and/or fasting plasma glucose >6.1 mmol/l)
- Family history of diabetes (type 1 og type 2 diabetes)
- Arrhythmia diagnosed prior to or at the time of inclusion
- ICD or pacemaker at the time of inclusion
- Severe heart failure (left ventricular ejection fraction <25%)
- Structural heart disease (Wolf-Parkinson-White syndrome, congenital heart disease, severe valve disease)
- Thyroid dysfunction (except for well-regulated eltroxine substituted myxoedema)
- Anemia (male: hemoglobin < 8.0; female: hemoglobin < 7.0 mmol/l)
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
Nombre de groupes / cohortes
Cohortes et interventions
Groupe / CohorteGroupe / Cohorte |
Intervention / TraitementIntervention / Traitement |
|---|---|
|
Patients with type 2 diabetes
Insulin-treated type 2 diabetes with diabetic complications
|
During the entire clamp, participants will be monitored by ECG, pulse oximetry, and blood pressure and plasma glucose will be measured bedside every fifth minute.
Additionally, patients with type 2 diabetes will be monitored by a loop recorder (LR) and a continuous glucose monitor (CGM).
Comparison of LR and CGM recordings with the recordings obtained by ECG Holter monitor and blood sampling will be used for validation of the method used in Part 2 of the study.
Blood samples will be drawn and analysed for changes in electrolytes, insulin, glucagon, catecholamines and cortisone.
A cardiac haemodynamic evaluation will be performed by echocardiography at baseline, hyperglycaemia, and hypoglycaemia.
Implantation of a loop-recorder
Monitoring with a continuous glucose monitor
|
|
Contrôles sains
Sujets témoins sains
|
During the entire clamp, participants will be monitored by ECG, pulse oximetry, and blood pressure and plasma glucose will be measured bedside every fifth minute.
Additionally, patients with type 2 diabetes will be monitored by a loop recorder (LR) and a continuous glucose monitor (CGM).
Comparison of LR and CGM recordings with the recordings obtained by ECG Holter monitor and blood sampling will be used for validation of the method used in Part 2 of the study.
Blood samples will be drawn and analysed for changes in electrolytes, insulin, glucagon, catecholamines and cortisone.
A cardiac haemodynamic evaluation will be performed by echocardiography at baseline, hyperglycaemia, and hypoglycaemia.
|
Que mesure l'étude ?
Principaux critères de jugement
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Part 1: Clinically relevant arrhythmias
Délai: 0-240 min during the combined hyper- and hypoglycaemic clamp
|
Composite endpoint including atrial fibrillation, brady-arrhythmias and tachy-arrhythmias.
Clinically relevant brady-arrhythmias are defined as sinus arrest for more than 3 seconds, frequency below 30 beats per minute (bpm), or high grade atrioventricular (AV) block including Mobitz Type II and third-degree AV block.
Clinically relevant tachy-arrhythmias are defined as sustained ventricular tachycardia (duration >30 seconds), and non-sustained ventricular tachycardia.
|
0-240 min during the combined hyper- and hypoglycaemic clamp
|
|
Part 2: Prevalence of clinically relevant arrhythmias as defined above
Délai: Within 12 months
|
Prevalence of clinically relevant arrhythmias as defined above
|
Within 12 months
|
|
Part 2: Clinically relevant arrhythmias during hypoglycaemia compared to euglycaemia
Délai: Within 12 months
|
Clinically relevant arrhythmias during hypoglycaemia compared to euglycaemia
|
Within 12 months
|
|
Part 2: Difference in MAGE
Délai: Within 12 months
|
Difference in mean amplitude of glycaemic excursions (MAGE) two hours preceding an arrhythmic event versus MAGE during non-event
|
Within 12 months
|
Mesures de résultats secondaires
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Part 1: Differences in mean corrected QT interval (QTc)
Délai: 0-240 min during the combined hyper- and hypoglycaemic clamp
|
Differences in mean corrected QT interval (QTc) between patients with type 2 diabetes and matched normal glucose tolerant individuals during the combined hyper- and hypoglycaemic clamp
|
0-240 min during the combined hyper- and hypoglycaemic clamp
|
|
Part 1: Difference in counter regulatory hormonal response
Délai: 0-240 min during the combined hyper- and hypoglycaemic clamp
|
Difference in counter regulatory hormonal response between patients with type 2 diabetes and matched normal glucose tolerant individuals during the combined hyper- and hypoglycaemic clamp
|
0-240 min during the combined hyper- and hypoglycaemic clamp
|
|
Part 1: Differences in haemodynamic regulation
Délai: 0-240 min during the combined hyper- and hypoglycaemic clamp
|
Differences in haemodynamic regulation (measured by echocardiography) between patients with type 2 diabetes and matched normal glucose tolerant individuals during a combined hyper- and hypoglycaemic clamp
|
0-240 min during the combined hyper- and hypoglycaemic clamp
|
|
Part 2: Clinical relevant arrhythmias during low glucose variability compared to high glucose variability.
Délai: Within 12 months
|
Clinical relevant arrhythmias during low glucose variability (LGV), defined as variations in plasma glucose below or equal to 5 mmol/l within two hours preceding an arrhythmic event, compared to high glucose variability (HGV), defined as variations in plasma glucose above 5 mmol/l within two hours preceding an arrhythmic event
|
Within 12 months
|
|
Part 2: The relationship between cardiovascular disease at baseline and clinically relevant arrhythmias in relation to hypoglycaemia and HGV
Délai: Within 12 months
|
The relationship between cardiovascular disease (heart failure and ischaemic heart disease) at baseline and clinically relevant arrhythmias in relation to hypoglycaemia and HGV
|
Within 12 months
|
|
Part 2: The relationship between pharmacological treatment at baseline and clinically relevant arrhythmias in relation to hypoglycaemia and HGV
Délai: Within 12 months
|
The relationship between pharmacological treatment at baseline and clinically relevant arrhythmias in relation to hypoglycaemia and HGV
|
Within 12 months
|
|
Part 2: The relationship between diabetes complication status at baseline and clinically relevant arrhythmias in relation to hypoglycaemia and HGV
Délai: Within 12 months
|
The relationship between diabetes complication status (neuropathy, nephropathy, retinopathy) at baseline and clinically relevant arrhythmias in relation to hypoglycaemia and HGV
|
Within 12 months
|
|
Part 2: Correlation between prevalence and total duration of hypoglycaemia and risk of clinically relevant arrhythmias
Délai: Within 12 months
|
Correlation between prevalence and total duration of hypoglycaemia and risk of clinically relevant arrhythmias
|
Within 12 months
|
|
Part 2: Correlation between plasma glucose variation and risk of clinical relevant arrhythmias
Délai: Within 12 months
|
Correlation between plasma glucose variation (variation in plasma glucose (Δ mmol/l) within two hours of the event) and risk of clinical relevant arrhythmias
|
Within 12 months
|
Collaborateurs et enquêteurs
Parrainer
Parrainer
Publications et liens utiles
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Réel)
Début de l'étude
Achèvement primaire (Réel)
Achèvement primaire
Achèvement de l'étude (Réel)
Achèvement de l'étude
Dates d'inscription aux études
Première soumission
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Première publication
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour publiée
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Dernière vérification
Plus d'information
Termes liés à cette étude
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
Autres numéros d'identification d'étude
- H-16046212
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .