Cette page a été traduite automatiquement et l'exactitude de la traduction n'est pas garantie. Veuillez vous référer au version anglaise pour un texte source.

Hypoglycaemia and Cardiac Arrhythmias in Type 2 Diabetes (HYPO-HEART)

30 octobre 2020 mis à jour par: Andreas Andersen, University Hospital, Gentofte, Copenhagen
Twenty-one patients with insulin-treated type 2 diabetes with diabetic complications will be recruited to Part 1 of the study, a three-hour combined hyper- and hypoglycaemic clamp, along with a control group of twenty-one individuals with normal glucose tolerance matched for age, gender, and body mass index. Patients with type 2 diabetes will be scheduled for a three-week run-in period with LR and CGM prior to participation in Part 1. Only patients with a well-functioning loop-recorder and who can comply with CGM will be included. Patients with type 2 diabetes will continue in part 2 of the study, a one year observational study employing CGM and LR and clinical examination after 1, 3, 6, 9, and 12 months and an extended observation period of 2 years employing LR and clinical examination.

Aperçu de l'étude

Type d'étude

Observationnel

Inscription (Réel)

42

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Lieux d'étude

      • Hellerup, Danemark, 2900
        • Gentofte Hospital

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

18 ans à 80 ans (Adulte, Adulte plus âgé)

Accepte les volontaires sains

Oui

Sexes éligibles pour l'étude

Tout

Méthode d'échantillonnage

Échantillon non probabiliste

Population étudiée

Patiens with insulin-treated type 2 diabetes with complications and healthy controls

La description

Inclusion Criteria:

Patients with type 2 diabetes

  • Informed and written consent
  • Type 2 diabetes diagnosed according to the criteria of the World Health Organization (WHO)
  • Treatment with insulin
  • Glycated haemoglobin A1c (HbA1c) ≤58 mmol/mol
  • One or more clinical relevant complications to diabetes defined as: peripheral neuropathy with vibration perception threshold of > 25 volt determined by biothesiometry, moderate to severe retinopathy, nephropathy (creatinine >130 μmol/l and/or albuminuria), and/or macrovascular disease. Macrovascular disease is defined as coronary disease (stable angina pectoris or previous unstable angina pectoris or myocardial infarct), cerebrovascular disease (previous stroke or transitional cerebral ischaemia), and peripheral vascular disease (previous intermittent claudication or prior acute ischemia)
  • Well-functioning LR during run-in period (acceptable readings judged by an arrhythmologist)
  • Participation in the extended study

Healthy individuals

  • HbA1c ≤42 mmol/mol
  • Fasting plasma glucose ≤6.1 mmol/l

Exclusion Criteria:

Patients with type 2 diabetes

  • Arrhythmia diagnosed prior to or at the time of inclusion
  • Implantable cardioverter defibrillator (ICD) or pacemaker at the time of inclusion
  • Severe heart failure (left ventricular ejection fraction <25%)
  • Structural heart disease (Wolf-Parkinson-White syndrome, congenital heart disease, severe valve disease)
  • Insulin naïve patients with type 2 diabetes
  • Thyroid dysfunction (except for well-regulated eltroxine substituted myxoedema)
  • Unable to comply with daily CGM during run-in period
  • Anemia (male: hemoglobin < 8.0; female: hemoglobin < 7.0 mmol/l)

Healthy individuals

  • Type 1 or type 2 diabetes
  • Prediabetes (HbA1c >42 mmol/l and/or fasting plasma glucose >6.1 mmol/l)
  • Family history of diabetes (type 1 og type 2 diabetes)
  • Arrhythmia diagnosed prior to or at the time of inclusion
  • ICD or pacemaker at the time of inclusion
  • Severe heart failure (left ventricular ejection fraction <25%)
  • Structural heart disease (Wolf-Parkinson-White syndrome, congenital heart disease, severe valve disease)
  • Thyroid dysfunction (except for well-regulated eltroxine substituted myxoedema)
  • Anemia (male: hemoglobin < 8.0; female: hemoglobin < 7.0 mmol/l)

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

Cohortes et interventions

Groupe / Cohorte
Intervention / Traitement
Patients with type 2 diabetes
Insulin-treated type 2 diabetes with diabetic complications
During the entire clamp, participants will be monitored by ECG, pulse oximetry, and blood pressure and plasma glucose will be measured bedside every fifth minute. Additionally, patients with type 2 diabetes will be monitored by a loop recorder (LR) and a continuous glucose monitor (CGM). Comparison of LR and CGM recordings with the recordings obtained by ECG Holter monitor and blood sampling will be used for validation of the method used in Part 2 of the study. Blood samples will be drawn and analysed for changes in electrolytes, insulin, glucagon, catecholamines and cortisone. A cardiac haemodynamic evaluation will be performed by echocardiography at baseline, hyperglycaemia, and hypoglycaemia.
Implantation of a loop-recorder
Monitoring with a continuous glucose monitor
Contrôles sains
Sujets témoins sains
During the entire clamp, participants will be monitored by ECG, pulse oximetry, and blood pressure and plasma glucose will be measured bedside every fifth minute. Additionally, patients with type 2 diabetes will be monitored by a loop recorder (LR) and a continuous glucose monitor (CGM). Comparison of LR and CGM recordings with the recordings obtained by ECG Holter monitor and blood sampling will be used for validation of the method used in Part 2 of the study. Blood samples will be drawn and analysed for changes in electrolytes, insulin, glucagon, catecholamines and cortisone. A cardiac haemodynamic evaluation will be performed by echocardiography at baseline, hyperglycaemia, and hypoglycaemia.

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
Part 1: Clinically relevant arrhythmias
Délai: 0-240 min during the combined hyper- and hypoglycaemic clamp
Composite endpoint including atrial fibrillation, brady-arrhythmias and tachy-arrhythmias. Clinically relevant brady-arrhythmias are defined as sinus arrest for more than 3 seconds, frequency below 30 beats per minute (bpm), or high grade atrioventricular (AV) block including Mobitz Type II and third-degree AV block. Clinically relevant tachy-arrhythmias are defined as sustained ventricular tachycardia (duration >30 seconds), and non-sustained ventricular tachycardia.
0-240 min during the combined hyper- and hypoglycaemic clamp
Part 2: Prevalence of clinically relevant arrhythmias as defined above
Délai: Within 12 months
Prevalence of clinically relevant arrhythmias as defined above
Within 12 months
Part 2: Clinically relevant arrhythmias during hypoglycaemia compared to euglycaemia
Délai: Within 12 months
Clinically relevant arrhythmias during hypoglycaemia compared to euglycaemia
Within 12 months
Part 2: Difference in MAGE
Délai: Within 12 months
Difference in mean amplitude of glycaemic excursions (MAGE) two hours preceding an arrhythmic event versus MAGE during non-event
Within 12 months

Mesures de résultats secondaires

Mesure des résultats
Description de la mesure
Délai
Part 1: Differences in mean corrected QT interval (QTc)
Délai: 0-240 min during the combined hyper- and hypoglycaemic clamp
Differences in mean corrected QT interval (QTc) between patients with type 2 diabetes and matched normal glucose tolerant individuals during the combined hyper- and hypoglycaemic clamp
0-240 min during the combined hyper- and hypoglycaemic clamp
Part 1: Difference in counter regulatory hormonal response
Délai: 0-240 min during the combined hyper- and hypoglycaemic clamp
Difference in counter regulatory hormonal response between patients with type 2 diabetes and matched normal glucose tolerant individuals during the combined hyper- and hypoglycaemic clamp
0-240 min during the combined hyper- and hypoglycaemic clamp
Part 1: Differences in haemodynamic regulation
Délai: 0-240 min during the combined hyper- and hypoglycaemic clamp
Differences in haemodynamic regulation (measured by echocardiography) between patients with type 2 diabetes and matched normal glucose tolerant individuals during a combined hyper- and hypoglycaemic clamp
0-240 min during the combined hyper- and hypoglycaemic clamp
Part 2: Clinical relevant arrhythmias during low glucose variability compared to high glucose variability.
Délai: Within 12 months
Clinical relevant arrhythmias during low glucose variability (LGV), defined as variations in plasma glucose below or equal to 5 mmol/l within two hours preceding an arrhythmic event, compared to high glucose variability (HGV), defined as variations in plasma glucose above 5 mmol/l within two hours preceding an arrhythmic event
Within 12 months
Part 2: The relationship between cardiovascular disease at baseline and clinically relevant arrhythmias in relation to hypoglycaemia and HGV
Délai: Within 12 months
The relationship between cardiovascular disease (heart failure and ischaemic heart disease) at baseline and clinically relevant arrhythmias in relation to hypoglycaemia and HGV
Within 12 months
Part 2: The relationship between pharmacological treatment at baseline and clinically relevant arrhythmias in relation to hypoglycaemia and HGV
Délai: Within 12 months
The relationship between pharmacological treatment at baseline and clinically relevant arrhythmias in relation to hypoglycaemia and HGV
Within 12 months
Part 2: The relationship between diabetes complication status at baseline and clinically relevant arrhythmias in relation to hypoglycaemia and HGV
Délai: Within 12 months
The relationship between diabetes complication status (neuropathy, nephropathy, retinopathy) at baseline and clinically relevant arrhythmias in relation to hypoglycaemia and HGV
Within 12 months
Part 2: Correlation between prevalence and total duration of hypoglycaemia and risk of clinically relevant arrhythmias
Délai: Within 12 months
Correlation between prevalence and total duration of hypoglycaemia and risk of clinically relevant arrhythmias
Within 12 months
Part 2: Correlation between plasma glucose variation and risk of clinical relevant arrhythmias
Délai: Within 12 months
Correlation between plasma glucose variation (variation in plasma glucose (Δ mmol/l) within two hours of the event) and risk of clinical relevant arrhythmias
Within 12 months

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Publications et liens utiles

La personne responsable de la saisie des informations sur l'étude fournit volontairement ces publications. Il peut s'agir de tout ce qui concerne l'étude.

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Réel)

1 février 2017

Achèvement primaire (Réel)

6 janvier 2020

Achèvement de l'étude (Réel)

6 janvier 2020

Dates d'inscription aux études

Première soumission

25 avril 2017

Première soumission répondant aux critères de contrôle qualité

10 mai 2017

Première publication (Réel)

11 mai 2017

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

2 novembre 2020

Dernière mise à jour soumise répondant aux critères de contrôle qualité

30 octobre 2020

Dernière vérification

1 octobre 2020

Plus d'information

Termes liés à cette étude

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Non

Étudie un produit d'appareil réglementé par la FDA américaine

Non

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

Essais cliniques sur Diabète sucré, Type 2

3
S'abonner