Hypoglycaemia and Cardiac Arrhythmias in Type 2 Diabetes (HYPO-HEART)
Panoramica dello studio
Stato
Stato
Condizioni
Condizioni
Intervento / Trattamento
Intervento / Trattamento
Tipo di studio
Tipo di studio
Iscrizione (Effettivo)
Iscrizione
Contatti e Sedi
Luoghi di studio
-
-
-
Hellerup, Danimarca, 2900
- Gentofte Hospital
-
-
Criteri di partecipazione
Criteri di ammissibilità
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Metodo di campionamento
Popolazione di studio
Descrizione
Inclusion Criteria:
Patients with type 2 diabetes
- Informed and written consent
- Type 2 diabetes diagnosed according to the criteria of the World Health Organization (WHO)
- Treatment with insulin
- Glycated haemoglobin A1c (HbA1c) ≤58 mmol/mol
- One or more clinical relevant complications to diabetes defined as: peripheral neuropathy with vibration perception threshold of > 25 volt determined by biothesiometry, moderate to severe retinopathy, nephropathy (creatinine >130 μmol/l and/or albuminuria), and/or macrovascular disease. Macrovascular disease is defined as coronary disease (stable angina pectoris or previous unstable angina pectoris or myocardial infarct), cerebrovascular disease (previous stroke or transitional cerebral ischaemia), and peripheral vascular disease (previous intermittent claudication or prior acute ischemia)
- Well-functioning LR during run-in period (acceptable readings judged by an arrhythmologist)
- Participation in the extended study
Healthy individuals
- HbA1c ≤42 mmol/mol
- Fasting plasma glucose ≤6.1 mmol/l
Exclusion Criteria:
Patients with type 2 diabetes
- Arrhythmia diagnosed prior to or at the time of inclusion
- Implantable cardioverter defibrillator (ICD) or pacemaker at the time of inclusion
- Severe heart failure (left ventricular ejection fraction <25%)
- Structural heart disease (Wolf-Parkinson-White syndrome, congenital heart disease, severe valve disease)
- Insulin naïve patients with type 2 diabetes
- Thyroid dysfunction (except for well-regulated eltroxine substituted myxoedema)
- Unable to comply with daily CGM during run-in period
- Anemia (male: hemoglobin < 8.0; female: hemoglobin < 7.0 mmol/l)
Healthy individuals
- Type 1 or type 2 diabetes
- Prediabetes (HbA1c >42 mmol/l and/or fasting plasma glucose >6.1 mmol/l)
- Family history of diabetes (type 1 og type 2 diabetes)
- Arrhythmia diagnosed prior to or at the time of inclusion
- ICD or pacemaker at the time of inclusion
- Severe heart failure (left ventricular ejection fraction <25%)
- Structural heart disease (Wolf-Parkinson-White syndrome, congenital heart disease, severe valve disease)
- Thyroid dysfunction (except for well-regulated eltroxine substituted myxoedema)
- Anemia (male: hemoglobin < 8.0; female: hemoglobin < 7.0 mmol/l)
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
Numero di gruppi/coorti
Coorti e interventi
Gruppo / CoorteGruppo / Coorte |
Intervento / TrattamentoIntervento / Trattamento |
|---|---|
|
Patients with type 2 diabetes
Insulin-treated type 2 diabetes with diabetic complications
|
During the entire clamp, participants will be monitored by ECG, pulse oximetry, and blood pressure and plasma glucose will be measured bedside every fifth minute.
Additionally, patients with type 2 diabetes will be monitored by a loop recorder (LR) and a continuous glucose monitor (CGM).
Comparison of LR and CGM recordings with the recordings obtained by ECG Holter monitor and blood sampling will be used for validation of the method used in Part 2 of the study.
Blood samples will be drawn and analysed for changes in electrolytes, insulin, glucagon, catecholamines and cortisone.
A cardiac haemodynamic evaluation will be performed by echocardiography at baseline, hyperglycaemia, and hypoglycaemia.
Implantation of a loop-recorder
Monitoring with a continuous glucose monitor
|
|
Controlli sani
Soggetti di controllo sani
|
During the entire clamp, participants will be monitored by ECG, pulse oximetry, and blood pressure and plasma glucose will be measured bedside every fifth minute.
Additionally, patients with type 2 diabetes will be monitored by a loop recorder (LR) and a continuous glucose monitor (CGM).
Comparison of LR and CGM recordings with the recordings obtained by ECG Holter monitor and blood sampling will be used for validation of the method used in Part 2 of the study.
Blood samples will be drawn and analysed for changes in electrolytes, insulin, glucagon, catecholamines and cortisone.
A cardiac haemodynamic evaluation will be performed by echocardiography at baseline, hyperglycaemia, and hypoglycaemia.
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Part 1: Clinically relevant arrhythmias
Lasso di tempo: 0-240 min during the combined hyper- and hypoglycaemic clamp
|
Composite endpoint including atrial fibrillation, brady-arrhythmias and tachy-arrhythmias.
Clinically relevant brady-arrhythmias are defined as sinus arrest for more than 3 seconds, frequency below 30 beats per minute (bpm), or high grade atrioventricular (AV) block including Mobitz Type II and third-degree AV block.
Clinically relevant tachy-arrhythmias are defined as sustained ventricular tachycardia (duration >30 seconds), and non-sustained ventricular tachycardia.
|
0-240 min during the combined hyper- and hypoglycaemic clamp
|
|
Part 2: Prevalence of clinically relevant arrhythmias as defined above
Lasso di tempo: Within 12 months
|
Prevalence of clinically relevant arrhythmias as defined above
|
Within 12 months
|
|
Part 2: Clinically relevant arrhythmias during hypoglycaemia compared to euglycaemia
Lasso di tempo: Within 12 months
|
Clinically relevant arrhythmias during hypoglycaemia compared to euglycaemia
|
Within 12 months
|
|
Part 2: Difference in MAGE
Lasso di tempo: Within 12 months
|
Difference in mean amplitude of glycaemic excursions (MAGE) two hours preceding an arrhythmic event versus MAGE during non-event
|
Within 12 months
|
Misure di risultato secondarie
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Part 1: Differences in mean corrected QT interval (QTc)
Lasso di tempo: 0-240 min during the combined hyper- and hypoglycaemic clamp
|
Differences in mean corrected QT interval (QTc) between patients with type 2 diabetes and matched normal glucose tolerant individuals during the combined hyper- and hypoglycaemic clamp
|
0-240 min during the combined hyper- and hypoglycaemic clamp
|
|
Part 1: Difference in counter regulatory hormonal response
Lasso di tempo: 0-240 min during the combined hyper- and hypoglycaemic clamp
|
Difference in counter regulatory hormonal response between patients with type 2 diabetes and matched normal glucose tolerant individuals during the combined hyper- and hypoglycaemic clamp
|
0-240 min during the combined hyper- and hypoglycaemic clamp
|
|
Part 1: Differences in haemodynamic regulation
Lasso di tempo: 0-240 min during the combined hyper- and hypoglycaemic clamp
|
Differences in haemodynamic regulation (measured by echocardiography) between patients with type 2 diabetes and matched normal glucose tolerant individuals during a combined hyper- and hypoglycaemic clamp
|
0-240 min during the combined hyper- and hypoglycaemic clamp
|
|
Part 2: Clinical relevant arrhythmias during low glucose variability compared to high glucose variability.
Lasso di tempo: Within 12 months
|
Clinical relevant arrhythmias during low glucose variability (LGV), defined as variations in plasma glucose below or equal to 5 mmol/l within two hours preceding an arrhythmic event, compared to high glucose variability (HGV), defined as variations in plasma glucose above 5 mmol/l within two hours preceding an arrhythmic event
|
Within 12 months
|
|
Part 2: The relationship between cardiovascular disease at baseline and clinically relevant arrhythmias in relation to hypoglycaemia and HGV
Lasso di tempo: Within 12 months
|
The relationship between cardiovascular disease (heart failure and ischaemic heart disease) at baseline and clinically relevant arrhythmias in relation to hypoglycaemia and HGV
|
Within 12 months
|
|
Part 2: The relationship between pharmacological treatment at baseline and clinically relevant arrhythmias in relation to hypoglycaemia and HGV
Lasso di tempo: Within 12 months
|
The relationship between pharmacological treatment at baseline and clinically relevant arrhythmias in relation to hypoglycaemia and HGV
|
Within 12 months
|
|
Part 2: The relationship between diabetes complication status at baseline and clinically relevant arrhythmias in relation to hypoglycaemia and HGV
Lasso di tempo: Within 12 months
|
The relationship between diabetes complication status (neuropathy, nephropathy, retinopathy) at baseline and clinically relevant arrhythmias in relation to hypoglycaemia and HGV
|
Within 12 months
|
|
Part 2: Correlation between prevalence and total duration of hypoglycaemia and risk of clinically relevant arrhythmias
Lasso di tempo: Within 12 months
|
Correlation between prevalence and total duration of hypoglycaemia and risk of clinically relevant arrhythmias
|
Within 12 months
|
|
Part 2: Correlation between plasma glucose variation and risk of clinical relevant arrhythmias
Lasso di tempo: Within 12 months
|
Correlation between plasma glucose variation (variation in plasma glucose (Δ mmol/l) within two hours of the event) and risk of clinical relevant arrhythmias
|
Within 12 months
|
Collaboratori e investigatori
Sponsor
Sponsor
Pubblicazioni e link utili
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Inizio studio
Completamento primario (Effettivo)
Completamento primario
Completamento dello studio (Effettivo)
Completamento dello studio
Date di iscrizione allo studio
Primo inviato
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Primo Inserito
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento pubblicato
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
Altri numeri di identificazione dello studio
- H-16046212
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .