Hypoglycaemia and Cardiac Arrhythmias in Type 2 Diabetes (HYPO-HEART)
Visão geral do estudo
Status
Status
Condições
Condições
Intervenção / Tratamento
Intervenção / Tratamento
Tipo de estudo
Tipo de estudo
Inscrição (Real)
Inscrição
Contactos e Locais
Locais de estudo
-
-
-
Hellerup, Dinamarca, 2900
- Gentofte Hospital
-
-
Critérios de participação
Critérios de elegibilidade
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Método de amostragem
População do estudo
Descrição
Inclusion Criteria:
Patients with type 2 diabetes
- Informed and written consent
- Type 2 diabetes diagnosed according to the criteria of the World Health Organization (WHO)
- Treatment with insulin
- Glycated haemoglobin A1c (HbA1c) ≤58 mmol/mol
- One or more clinical relevant complications to diabetes defined as: peripheral neuropathy with vibration perception threshold of > 25 volt determined by biothesiometry, moderate to severe retinopathy, nephropathy (creatinine >130 μmol/l and/or albuminuria), and/or macrovascular disease. Macrovascular disease is defined as coronary disease (stable angina pectoris or previous unstable angina pectoris or myocardial infarct), cerebrovascular disease (previous stroke or transitional cerebral ischaemia), and peripheral vascular disease (previous intermittent claudication or prior acute ischemia)
- Well-functioning LR during run-in period (acceptable readings judged by an arrhythmologist)
- Participation in the extended study
Healthy individuals
- HbA1c ≤42 mmol/mol
- Fasting plasma glucose ≤6.1 mmol/l
Exclusion Criteria:
Patients with type 2 diabetes
- Arrhythmia diagnosed prior to or at the time of inclusion
- Implantable cardioverter defibrillator (ICD) or pacemaker at the time of inclusion
- Severe heart failure (left ventricular ejection fraction <25%)
- Structural heart disease (Wolf-Parkinson-White syndrome, congenital heart disease, severe valve disease)
- Insulin naïve patients with type 2 diabetes
- Thyroid dysfunction (except for well-regulated eltroxine substituted myxoedema)
- Unable to comply with daily CGM during run-in period
- Anemia (male: hemoglobin < 8.0; female: hemoglobin < 7.0 mmol/l)
Healthy individuals
- Type 1 or type 2 diabetes
- Prediabetes (HbA1c >42 mmol/l and/or fasting plasma glucose >6.1 mmol/l)
- Family history of diabetes (type 1 og type 2 diabetes)
- Arrhythmia diagnosed prior to or at the time of inclusion
- ICD or pacemaker at the time of inclusion
- Severe heart failure (left ventricular ejection fraction <25%)
- Structural heart disease (Wolf-Parkinson-White syndrome, congenital heart disease, severe valve disease)
- Thyroid dysfunction (except for well-regulated eltroxine substituted myxoedema)
- Anemia (male: hemoglobin < 8.0; female: hemoglobin < 7.0 mmol/l)
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
Número de grupos/coortes
Coortes e Intervenções
Grupo / CoorteGrupo / Coorte |
Intervenção / TratamentoIntervenção / Tratamento |
|---|---|
|
Patients with type 2 diabetes
Insulin-treated type 2 diabetes with diabetic complications
|
During the entire clamp, participants will be monitored by ECG, pulse oximetry, and blood pressure and plasma glucose will be measured bedside every fifth minute.
Additionally, patients with type 2 diabetes will be monitored by a loop recorder (LR) and a continuous glucose monitor (CGM).
Comparison of LR and CGM recordings with the recordings obtained by ECG Holter monitor and blood sampling will be used for validation of the method used in Part 2 of the study.
Blood samples will be drawn and analysed for changes in electrolytes, insulin, glucagon, catecholamines and cortisone.
A cardiac haemodynamic evaluation will be performed by echocardiography at baseline, hyperglycaemia, and hypoglycaemia.
Implantation of a loop-recorder
Monitoring with a continuous glucose monitor
|
|
Controles saudáveis
Sujeitos de controle saudáveis
|
During the entire clamp, participants will be monitored by ECG, pulse oximetry, and blood pressure and plasma glucose will be measured bedside every fifth minute.
Additionally, patients with type 2 diabetes will be monitored by a loop recorder (LR) and a continuous glucose monitor (CGM).
Comparison of LR and CGM recordings with the recordings obtained by ECG Holter monitor and blood sampling will be used for validation of the method used in Part 2 of the study.
Blood samples will be drawn and analysed for changes in electrolytes, insulin, glucagon, catecholamines and cortisone.
A cardiac haemodynamic evaluation will be performed by echocardiography at baseline, hyperglycaemia, and hypoglycaemia.
|
O que o estudo está medindo?
Medidas de resultados primários
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Part 1: Clinically relevant arrhythmias
Prazo: 0-240 min during the combined hyper- and hypoglycaemic clamp
|
Composite endpoint including atrial fibrillation, brady-arrhythmias and tachy-arrhythmias.
Clinically relevant brady-arrhythmias are defined as sinus arrest for more than 3 seconds, frequency below 30 beats per minute (bpm), or high grade atrioventricular (AV) block including Mobitz Type II and third-degree AV block.
Clinically relevant tachy-arrhythmias are defined as sustained ventricular tachycardia (duration >30 seconds), and non-sustained ventricular tachycardia.
|
0-240 min during the combined hyper- and hypoglycaemic clamp
|
|
Part 2: Prevalence of clinically relevant arrhythmias as defined above
Prazo: Within 12 months
|
Prevalence of clinically relevant arrhythmias as defined above
|
Within 12 months
|
|
Part 2: Clinically relevant arrhythmias during hypoglycaemia compared to euglycaemia
Prazo: Within 12 months
|
Clinically relevant arrhythmias during hypoglycaemia compared to euglycaemia
|
Within 12 months
|
|
Part 2: Difference in MAGE
Prazo: Within 12 months
|
Difference in mean amplitude of glycaemic excursions (MAGE) two hours preceding an arrhythmic event versus MAGE during non-event
|
Within 12 months
|
Medidas de resultados secundários
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Part 1: Differences in mean corrected QT interval (QTc)
Prazo: 0-240 min during the combined hyper- and hypoglycaemic clamp
|
Differences in mean corrected QT interval (QTc) between patients with type 2 diabetes and matched normal glucose tolerant individuals during the combined hyper- and hypoglycaemic clamp
|
0-240 min during the combined hyper- and hypoglycaemic clamp
|
|
Part 1: Difference in counter regulatory hormonal response
Prazo: 0-240 min during the combined hyper- and hypoglycaemic clamp
|
Difference in counter regulatory hormonal response between patients with type 2 diabetes and matched normal glucose tolerant individuals during the combined hyper- and hypoglycaemic clamp
|
0-240 min during the combined hyper- and hypoglycaemic clamp
|
|
Part 1: Differences in haemodynamic regulation
Prazo: 0-240 min during the combined hyper- and hypoglycaemic clamp
|
Differences in haemodynamic regulation (measured by echocardiography) between patients with type 2 diabetes and matched normal glucose tolerant individuals during a combined hyper- and hypoglycaemic clamp
|
0-240 min during the combined hyper- and hypoglycaemic clamp
|
|
Part 2: Clinical relevant arrhythmias during low glucose variability compared to high glucose variability.
Prazo: Within 12 months
|
Clinical relevant arrhythmias during low glucose variability (LGV), defined as variations in plasma glucose below or equal to 5 mmol/l within two hours preceding an arrhythmic event, compared to high glucose variability (HGV), defined as variations in plasma glucose above 5 mmol/l within two hours preceding an arrhythmic event
|
Within 12 months
|
|
Part 2: The relationship between cardiovascular disease at baseline and clinically relevant arrhythmias in relation to hypoglycaemia and HGV
Prazo: Within 12 months
|
The relationship between cardiovascular disease (heart failure and ischaemic heart disease) at baseline and clinically relevant arrhythmias in relation to hypoglycaemia and HGV
|
Within 12 months
|
|
Part 2: The relationship between pharmacological treatment at baseline and clinically relevant arrhythmias in relation to hypoglycaemia and HGV
Prazo: Within 12 months
|
The relationship between pharmacological treatment at baseline and clinically relevant arrhythmias in relation to hypoglycaemia and HGV
|
Within 12 months
|
|
Part 2: The relationship between diabetes complication status at baseline and clinically relevant arrhythmias in relation to hypoglycaemia and HGV
Prazo: Within 12 months
|
The relationship between diabetes complication status (neuropathy, nephropathy, retinopathy) at baseline and clinically relevant arrhythmias in relation to hypoglycaemia and HGV
|
Within 12 months
|
|
Part 2: Correlation between prevalence and total duration of hypoglycaemia and risk of clinically relevant arrhythmias
Prazo: Within 12 months
|
Correlation between prevalence and total duration of hypoglycaemia and risk of clinically relevant arrhythmias
|
Within 12 months
|
|
Part 2: Correlation between plasma glucose variation and risk of clinical relevant arrhythmias
Prazo: Within 12 months
|
Correlation between plasma glucose variation (variation in plasma glucose (Δ mmol/l) within two hours of the event) and risk of clinical relevant arrhythmias
|
Within 12 months
|
Colaboradores e Investigadores
Patrocinador
Patrocinador
Publicações e links úteis
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Real)
Início do estudo
Conclusão Primária (Real)
Conclusão Primária
Conclusão do estudo (Real)
Conclusão do estudo
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Primeira postagem
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última Atualização Postada
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Última verificação
Mais Informações
Termos relacionados a este estudo
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
Outros números de identificação do estudo
- H-16046212
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .