The Effectiveness of BreatheMAX Breathing Device on Secretion Clearance (ESMOSC)

22 mars 2010 mis à jour par: Khon Kaen University

The Effectiveness of BreatheMAX Breathing Device on Airway Secretion Clearance in Patients With Ventilatory Dependence

The purpose of this study is to determined effects of BreatheMAX on secretion clearance.

Aperçu de l'étude

Statut

Inconnue

Les conditions

Type d'étude

Interventionnel

Inscription (Anticipé)

14

Phase

  • Phase 2
  • Phase 3

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Lieux d'étude

    • Khon Kaen
      • Muang, Khon Kaen, Thaïlande, 40002
        • Recrutement
        • Pulmonary research room of physical therapy department, Faculty of associated medical sciences, Khon Kaen University
        • Contact:
        • Contact:

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

15 ans à 85 ans (Enfant, Adulte, Adulte plus âgé)

Accepte les volontaires sains

Non

Sexes éligibles pour l'étude

Tout

La description

Inclusion Criteria:

  • One sign of secretion accumulation in bronchi
  • Stable cardiopulmonary function
  • Good consciousness and good co-operation

Exclusion Criteria:

  • Massive hemoptysis
  • Pneumothorax (untreated)

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

  • Objectif principal: Traitement
  • Répartition: Randomisé
  • Modèle interventionnel: Affectation croisée
  • Masquage: Double

Armes et Interventions

Groupe de participants / Bras
Intervention / Traitement
Expérimental: breathing exercise
BreatheMAX breathing device is Water pressure Threshold Bottle. The level of water in the cylinder determines the load for treatment. In the treatment using 20% PNIP (Peak negative inspiratory pressure) was performed with 6-10 breaths/set; 10 set/day
secretion clearance, breathing exercise

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
secretion wet weight (gram)
Délai: Three hours before, ten hours after treatment and night-time (02.00-07.00 am.)
Airway mucus secretion was collected for three hours before and ten hours after treatment based on an auditory airway secretion sound and collected again at 02.00-07.00 am.The mucus secretion was collected by sterile suctioning technique via tracheostomy tube without adding any saline or sterile water.
Three hours before, ten hours after treatment and night-time (02.00-07.00 am.)
viscosity of secretion
Délai: Three hours before and after treatment
The secretion were collected in three hours before and after treatment, It were measured viscosity by First The mucus was gently homogenized by tissue grinder 5 ml (Cw11-205, Cowie, UK) for six minute at 37 degree celsius Second using Micro-Oswald viscometers with a capillary diameter of 0.77 mm for viscosity measure at same temperature in each sample(before and after).
Three hours before and after treatment

Mesures de résultats secondaires

Mesure des résultats
Description de la mesure
Délai
Heart rate (beat/min)
Délai: Before, during breathing exercise with device and immediate after treatment
Heart rate was monitored before, during and immediate after breathing exercise with BreatheMAX (6-10 beats/set, 10 set/day and rest between ste for 1 minute)
Before, during breathing exercise with device and immediate after treatment
Oxygen saturation (%SpO2)
Délai: Before, during breathing exercise with device and immediate after treatment
Oxygen saturation was monitored before, during and immediate after breathing exercise with BreatheMAX (6-10 beats/set, 10 set/day and rest between set for 1 minute)
Before, during breathing exercise with device and immediate after treatment
Respiratory rate (times/min)
Délai: In rest interval between set (1 minute)
Respiratory rate was measured by manual for 1 minute before, rest interval between set and immediate after breathing exercise with device (during the patients reconnection mechanical ventilation)
In rest interval between set (1 minute)

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Les enquêteurs

  • Chaise d'étude: Sujittra Kluayhomthong, Bachelor, Physical Therapy department, Faculty of Associated Medical Sciences, Khon Kaen university
  • Directeur d'études: Chulee CU Jones, Philosophy, Physical Therapy Department, Faculty of Associated Medical Sciences, Khon Kaen university, Thailand
  • Directeur d'études: Wilaiwan Khrisanapant, Philosophy, Department of physiology, Faculty of medicine, Khon Kaen university

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude

1 août 2009

Achèvement primaire (Réel)

1 décembre 2009

Dates d'inscription aux études

Première soumission

7 janvier 2010

Première soumission répondant aux critères de contrôle qualité

22 mars 2010

Première publication (Estimation)

23 mars 2010

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Estimation)

23 mars 2010

Dernière mise à jour soumise répondant aux critères de contrôle qualité

22 mars 2010

Dernière vérification

1 janvier 2010

Plus d'information

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

Essais cliniques sur Les maladies pulmonaires

Essais cliniques sur BreatheMAX breathing device

S'abonner