The Effectiveness of BreatheMAX Breathing Device on Secretion Clearance (ESMOSC)
22 de marzo de 2010 actualizado por: Khon Kaen University
The Effectiveness of BreatheMAX Breathing Device on Airway Secretion Clearance in Patients With Ventilatory Dependence
The purpose of this study is to determined effects of BreatheMAX on secretion clearance.
Descripción general del estudio
Estado
Desconocido
Condiciones
Intervención / Tratamiento
Tipo de estudio
Intervencionista
Inscripción (Anticipado)
14
Fase
- Fase 2
- Fase 3
Contactos y Ubicaciones
Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.
Ubicaciones de estudio
-
-
Khon Kaen
-
Muang, Khon Kaen, Tailandia, 40002
- Reclutamiento
- Pulmonary research room of physical therapy department, Faculty of associated medical sciences, Khon Kaen University
-
Contacto:
- Sujittra Kluayhomthong, Bachelor
- Número de teléfono: 668-139-0647
- Correo electrónico: rabbit_tigger@hotmail.com
-
Contacto:
- Chulee CU Jones, Philosophy
- Número de teléfono: 664-320-2399
- Correo electrónico: chujones46@yahoo.co.uk
-
-
Criterios de participación
Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.
Criterio de elegibilidad
Edades elegibles para estudiar
15 años a 85 años (Niño, Adulto, Adulto Mayor)
Acepta Voluntarios Saludables
No
Géneros elegibles para el estudio
Todos
Descripción
Inclusion Criteria:
- One sign of secretion accumulation in bronchi
- Stable cardiopulmonary function
- Good consciousness and good co-operation
Exclusion Criteria:
- Massive hemoptysis
- Pneumothorax (untreated)
Plan de estudios
Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Tratamiento
- Asignación: Aleatorizado
- Modelo Intervencionista: Asignación cruzada
- Enmascaramiento: Doble
Armas e Intervenciones
Grupo de participantes/brazo |
Intervención / Tratamiento |
|---|---|
|
Experimental: breathing exercise
BreatheMAX breathing device is Water pressure Threshold Bottle.
The level of water in the cylinder determines the load for treatment.
In the treatment using 20% PNIP (Peak negative inspiratory pressure) was performed with 6-10 breaths/set; 10 set/day
|
secretion clearance, breathing exercise
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
secretion wet weight (gram)
Periodo de tiempo: Three hours before, ten hours after treatment and night-time (02.00-07.00 am.)
|
Airway mucus secretion was collected for three hours before and ten hours after treatment based on an auditory airway secretion sound and collected again at 02.00-07.00
am.The mucus secretion was collected by sterile suctioning technique via tracheostomy tube without adding any saline or sterile water.
|
Three hours before, ten hours after treatment and night-time (02.00-07.00 am.)
|
|
viscosity of secretion
Periodo de tiempo: Three hours before and after treatment
|
The secretion were collected in three hours before and after treatment, It were measured viscosity by First The mucus was gently homogenized by tissue grinder 5 ml (Cw11-205, Cowie, UK) for six minute at 37 degree celsius Second using Micro-Oswald viscometers with a capillary diameter of 0.77 mm for viscosity measure at same temperature in each sample(before and after).
|
Three hours before and after treatment
|
Medidas de resultado secundarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Heart rate (beat/min)
Periodo de tiempo: Before, during breathing exercise with device and immediate after treatment
|
Heart rate was monitored before, during and immediate after breathing exercise with BreatheMAX (6-10 beats/set, 10 set/day and rest between ste for 1 minute)
|
Before, during breathing exercise with device and immediate after treatment
|
|
Oxygen saturation (%SpO2)
Periodo de tiempo: Before, during breathing exercise with device and immediate after treatment
|
Oxygen saturation was monitored before, during and immediate after breathing exercise with BreatheMAX (6-10 beats/set, 10 set/day and rest between set for 1 minute)
|
Before, during breathing exercise with device and immediate after treatment
|
|
Respiratory rate (times/min)
Periodo de tiempo: In rest interval between set (1 minute)
|
Respiratory rate was measured by manual for 1 minute before, rest interval between set and immediate after breathing exercise with device (during the patients reconnection mechanical ventilation)
|
In rest interval between set (1 minute)
|
Colaboradores e Investigadores
Aquí es donde encontrará personas y organizaciones involucradas en este estudio.
Patrocinador
Investigadores
- Silla de estudio: Sujittra Kluayhomthong, Bachelor, Physical Therapy department, Faculty of Associated Medical Sciences, Khon Kaen university
- Director de estudio: Chulee CU Jones, Philosophy, Physical Therapy Department, Faculty of Associated Medical Sciences, Khon Kaen university, Thailand
- Director de estudio: Wilaiwan Khrisanapant, Philosophy, Department of physiology, Faculty of medicine, Khon Kaen university
Fechas de registro del estudio
Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.
Fechas importantes del estudio
Inicio del estudio
1 de agosto de 2009
Finalización primaria (Actual)
1 de diciembre de 2009
Fechas de registro del estudio
Enviado por primera vez
7 de enero de 2010
Primero enviado que cumplió con los criterios de control de calidad
22 de marzo de 2010
Publicado por primera vez (Estimar)
23 de marzo de 2010
Actualizaciones de registros de estudio
Última actualización publicada (Estimar)
23 de marzo de 2010
Última actualización enviada que cumplió con los criterios de control de calidad
22 de marzo de 2010
Última verificación
1 de enero de 2010
Más información
Términos relacionados con este estudio
Palabras clave
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
- 47660279
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .
Ensayos clínicos sobre BreatheMAX breathing device
-
Khon Kaen UniversityTerminadoRetención de secreciones bronquialesTailandia
-
Khon Kaen UniversityTerminado
-
Khajonsak PongpanitDesconocidoAfección pulmonar obstructiva crónicaTailandia
-
Yunnan Cancer HospitalReclutamiento