Cette page a été traduite automatiquement et l'exactitude de la traduction n'est pas garantie. Veuillez vous référer au version anglaise pour un texte source.

Optic Coherence Tomography in Patients With Amyotrophic Lateral Sclerosis

16 décembre 2017 mis à jour par: Achraf Makki, American University of Beirut Medical Center
Amyotrophic Lateral Sclerosis (ALS) is an adult-onset, devastating, neurodegenerative disease characterized by the loss of cortical, brain stem, and spinal motor neurons. Visual evoked potentials studies in patients with ALS suggest visual pathway involvement. Optic coherence tomography (OCT) is a non-invasive cross-sectional imaging modality measuring the optical reflections in biological tissues. The main objective of this observational cohort study is to explore the correlation between changes on OCT retinal parameters and and clinical disability as measured by the ALS Functional Rating Scale (ALS-FRS-r) in patients with ALS at baseline, 3 and 6 months. A secondary objective is to explore the correlation between changes in retinal OCT parameters and pulmonary function tests (FVC and FEV1) in this cohort of patients with ALS. A parallel cohort of healthy age and sex matched subjects will participate as controls to obtain reference values of their retinal layers' thickness at baseline, 3 and 6 months.

Aperçu de l'étude

Type d'étude

Interventionnel

Inscription (Anticipé)

30

Phase

  • N'est pas applicable

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

  • Enfant
  • Adulte
  • Adulte plus âgé

Accepte les volontaires sains

Oui

Sexes éligibles pour l'étude

Tout

La description

Inclusion Criteria:

  • Diagnosis of ALS according to the El Escorial criteria.
  • Age 18 years to 80 years old
  • Disease duration less than 36 months
  • Patients logistically able to attend and be evaluated at baseline, 3 and 6 months

Exclusion Criteria:

  • Patients with diabetes mellitus
  • Patients with glaucoma, refractive errors of ± 6 diopters or more, or other ophthalmologic disorders such as media opacities that could interfere with retinal OCT assessment

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

  • Objectif principal: Diagnostique
  • Répartition: Non randomisé
  • Modèle interventionnel: Affectation parallèle
  • Masquage: Aucun (étiquette ouverte)

Armes et Interventions

Groupe de participants / Bras
Intervention / Traitement
Autre: Patients with Amyotrophic lateral sclerosis
Patients diagnosed with amyotrophic lateral sclerosis
Optic coherence tomography measures retinal layer thickness, macular volume , and cell inner plexiform layer.
Pulmonary function test measures forced vital capacity and forced expiratory volume in one second.
Autre: Control
Parallel cohort of healthy age and sex matched subjects
Optic coherence tomography measures retinal layer thickness, macular volume , and cell inner plexiform layer.
Pulmonary function test measures forced vital capacity and forced expiratory volume in one second.

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
Change in retinal layer thickness parameters over 3 and 6 months in ALS patients
Délai: 6 months
Observing the change in retinal layers thickness parameters in micrometers in ALS patients from baseline to 3 and 6 months
6 months

Mesures de résultats secondaires

Mesure des résultats
Description de la mesure
Délai
Comparison of changes in retinal layer thickness parameters over 3 and 6 months between ALS patients and their healthy controls
Délai: 6 month
Comparison of changes in retinal layer thickness parameters over 3 and 6 months between ALS patients and their healthy controls in micrometers
6 month
Correlation between changes in retinal layers thickness and ALS-FRS scores in patients with ALS
Délai: 6 month
Correlation between changes in retinal layers thickness in micrometers and ALS-FRS scores in ALS patients over 3 and 6 month
6 month
Correlation between changes in retinal layers thickness and Pulmonary function test parameters in ALS patients over 3 and 6 months
Délai: 6 month
Correlation between changes in retinal layers thickness parameters in micrometers and changes in FEV1 in liters and FVC in liters on pulmonary function testing in patients with ALS over 3 and 6 month
6 month

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Publications et liens utiles

La personne responsable de la saisie des informations sur l'étude fournit volontairement ces publications. Il peut s'agir de tout ce qui concerne l'étude.

Publications générales

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Anticipé)

3 janvier 2018

Achèvement primaire (Anticipé)

28 juillet 2018

Achèvement de l'étude (Anticipé)

28 septembre 2018

Dates d'inscription aux études

Première soumission

6 décembre 2017

Première soumission répondant aux critères de contrôle qualité

16 décembre 2017

Première publication (Réel)

19 décembre 2017

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

19 décembre 2017

Dernière mise à jour soumise répondant aux critères de contrôle qualité

16 décembre 2017

Dernière vérification

1 décembre 2017

Plus d'information

Termes liés à cette étude

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Non

Étudie un produit d'appareil réglementé par la FDA américaine

Non

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

Essais cliniques sur Optic coherence tomography

S'abonner