X-BS Ortho Bone Graft Study
Randomised Investigation of the Osteoconductive Performance and Safety of FDBS Bone Graft, With Contextual Reference to IBS, in the Filling of Orthopaedic Bone Defects.
Randomised investigation of the osteoconductive performance and safety of CE-marked FDBS bone graft (GraftR3®), with contextual reference to CE-marked IBS (MBCP® Putty), in the filling of orthopaedic bone defects.
Aperçu de l'étude
Statut
Les conditions
Intervention / Traitement
Description détaillée
The primary purpose of this study is to collect clinical investigation data on the performance and safety of the CE-marked FDBS bone graft (GraftR3®) for the reconstruction of bony voids or bone gaps, in orthopaedic applications that are not intrinsic to the stability of the bone structure. It acts as a bone void filler by occupying the defect and supporting bone ingrowth from the surrounding viable tissue.
The study is sponsored by Advanced Medical Solutions (Nantes) and will provide essential clinical evidence to support the clinical evaluation of FDBS (GraftR3®).
For contextual interpretation, a reference arm including IBS (MBCP® Putty), a CE-marked bone substitute with established conformity to the relevant essential requirements, has been incorporated. This will allow descriptive comparison with a marketed product while maintaining the primary focus on the CE-marked device FDBS.
Type d'étude
Inscription (Estimé)
Phase
- N'est pas applicable
Contacts et emplacements
Coordonnées de l'étude
- Nom: Susan Clark
- Numéro de téléphone: 01606863500
- E-mail: susan.clark@admedsol.com
Sauvegarde des contacts de l'étude
- Nom: Loïc Limon-Duparcmeur
- Numéro de téléphone: 01606863500
- E-mail: loiclimonduparcmeur@admedsol.com
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
La description
Inclusion Criteria:
-
Patient is male or female, 18 - 85 years old;
-
Patient is willing and able to give written informed consent;
-
Patient is able to comply with a prior medical examination;
-
Patient is or has been scheduled for a surgical procedure to correct epiphyso-metaphyseal and/or metaphyso-diaphyseal bone void in one of the following anatomical locations either after traumatic injury or elective surgical reconstruction:
- Proximal humerus ▪ Distal radius
- Distal femur ▪ Proximal tibia ▪ Distal tibia
-
Patient is willing and able to comply with the study procedures during surgery and the post-surgical follow up period, up to 12 months.
Exclusion Criteria:
- Patient has had an infection in the same extremity within last 24 months;
- Patient has bone necrosis either after traumatic injury or elective surgical reconstruction at the surgical site;
- Patient has cellulitis;
- Patient has granuloma or non-curetted cyst;
- Patient has a current or previous diagnosis of osteomyelitis;
- Patient has a clinically significant degenerative bone disease;
- Patient has an history of uncontrolled diabetes;
- Patient is alcoholic and/or heavy smoker (> 20 cigarettes per day);
- Patient has a congenital or acquired immunodeficiency;
- Patient has severe bone loss (≥ 40cm3);
- Patient is on long-term steroidal therapy or treatment acting on the calcium or phosphorus metabolism;
- Patient is or has been scheduled for surgery that would involve intra-articular implantation of the study device;
- Patient who has or had an uncontained bone void (cavity) created as a result of trauma injury or surgically created;
- Patient was exposed to any radiation (e.g. X-Rays, handling of radiolabelled materials) other than the normal background radiation within the 12 months before the screening visit;
- Patient is pregnant or breastfeeding;
- Patient who is an employee at the study site;
- Patient is known to be non-compliant with medical treatment or follow-up
- Patient has any significant or unstable medical/psychiatric condition that, in the opinion of the Investigator, would interfere with their ability to participate in the study;
- Patient is currently enrolled or planning to enrol in another clinical study or treatment with another investigational drug/device that may interfere with the assessments, visits or outcomes of this study.
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Traitement
- Répartition: Randomisé
- Modèle interventionnel: Affectation parallèle
- Masquage: Double
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
|---|---|
|
Comparateur actif: FDBS (GraftR3®)
The CE-marked device FDBS (GraftR3®) is a powder that presents an interconnected network that enables the colonization of bone cells and biological fluid uniformly within the matrix required for the biological exchanges particularly for bone ingrowth. It is intended for the reconstruction of bony voids or bone gaps in orthopaedic applications that are not intrinsic to the stability of the bone structure. It acts as a bone void filler by occupying the defect and supporting bone ingrowth from the surrounding viable tissue. The clinical investigation is designed to generate data on the performance and safety of FDBS in orthopaedic trauma surgery. |
Use of FDBS (GraftR3®) in surgical procedure to correct epiphyso-metaphyseal and/or metaphyso-diaphyseal bone defect in one of the following anatomical locations: Proximal humerus, Distal radius, Distal femur, Proximal tibia, Distal tibia. |
|
Comparateur actif: IBS (MBCP® Putty)
The CE-marked device IBS (MBCP® Putty) is an injectable bone substitute to fill and reconstruct bone voids or bone gaps of the skeletal system (e.g. extremities, spine and pelvis). It acts as a bone void filler by occupying the defect and supporting bone ingrowth from the surrounding viable tissue. For contextual interpretation, the study will include patients treated with this technology, as published data remain limited for certain indications such as surgically created bone defects (e.g. post cyst removal) or bone gaps due to traumatic injury |
Use of IBS (MBCP® Putty) in surgical procedure to correct epiphyso-metaphyseal and/or metaphyso-diaphyseal bone defect in one of the following anatomical locations: Proximal humerus, Distal radius, Distal femur, Proximal tibia, Distal tibia. |
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Evaluation of performance and safety of FDBS and IBS in the reconstruction of bone voids in the extremities
Délai: At 12 months post-surgery
|
Achievement of successful bone integration (without occurrence of Major Adverse Events) through radiological evaluation within 12 months by assessing interdigitation in 3 out of 4 anatomical planes (anterior/posterior/lateral/medial) |
At 12 months post-surgery
|
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Evaluation of device-related Adverse Events associated with FDBS and IBS in the reconstruction of bone voids in the extremities
Délai: Within 12 months post-surgery
|
Incidence of device related Adverse Events |
Within 12 months post-surgery
|
|
Functional evaluation after use of FDBS and IBS in the reconstruction of bone voids in the upper extremities
Délai: Within 12 months post-surgery
|
Functional mobility restoration by scoring patient's physical disability and symptoms through QuickDASH outcome measure |
Within 12 months post-surgery
|
|
Functional evaluation after use of FDBS and IBS in the reconstruction of bone voids in the lower extremities
Délai: Within 12 months post-surgery
|
Functional mobility restoration by scoring patient's physical disability and symptoms through LEFS outcome measure |
Within 12 months post-surgery
|
|
Evaluation of subject's pain after use of FDBS and IBS in the reconstruction of bone voids in the extremities
Délai: Within 12 months post-surgery
|
Patient's pain intensity at trauma/surgical site 0 = no pain; 10 = worst pain imagineable |
Within 12 months post-surgery
|
|
Evaluation of usability of FDBS and IBS in the reconstruction of bone voids in the extremities
Délai: Within 12 months post-surgery
|
Clinician satisfaction with use of FDBS and IBS as per IFU |
Within 12 months post-surgery
|
|
Evaluation of the difference in performance of FDBS versus IBS in the reconstruction of bone defects in the extremities
Délai: At 12 months post-surgery
|
Difference between FDBS and IBS in successful rates of bone integration through radiological evaluation at 12 months |
At 12 months post-surgery
|
Collaborateurs et enquêteurs
Parrainer
Collaborateurs
Les enquêteurs
- Chercheur principal: Peter Giannoudis, Leeds General Infirmary, Great George Street Leeds LS1 3EX, United Kingdom
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Estimé)
Achèvement primaire (Estimé)
Achèvement de l'étude (Estimé)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Mots clés
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- STD-030-001
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .