- ICH GCP
- Registro de ensaios clínicos dos EUA
- Ensaio Clínico NCT06326827
X-BS Ortho Bone Graft Study
Randomised Investigation of the Osteoconductive Performance and Safety of FDBS Bone Graft, With Contextual Reference to IBS, in the Filling of Orthopaedic Bone Defects.
Randomised investigation of the osteoconductive performance and safety of CE-marked FDBS bone graft (GraftR3®), with contextual reference to CE-marked IBS (MBCP® Putty), in the filling of orthopaedic bone defects.
Visão geral do estudo
Status
Condições
Intervenção / Tratamento
Descrição detalhada
The primary purpose of this study is to collect clinical investigation data on the performance and safety of the CE-marked FDBS bone graft (GraftR3®) for the reconstruction of bony voids or bone gaps, in orthopaedic applications that are not intrinsic to the stability of the bone structure. It acts as a bone void filler by occupying the defect and supporting bone ingrowth from the surrounding viable tissue.
The study is sponsored by Advanced Medical Solutions (Nantes) and will provide essential clinical evidence to support the clinical evaluation of FDBS (GraftR3®).
For contextual interpretation, a reference arm including IBS (MBCP® Putty), a CE-marked bone substitute with established conformity to the relevant essential requirements, has been incorporated. This will allow descriptive comparison with a marketed product while maintaining the primary focus on the CE-marked device FDBS.
Tipo de estudo
Inscrição (Estimado)
Estágio
- Não aplicável
Contactos e Locais
Contato de estudo
- Nome: Susan Clark
- Número de telefone: 01606863500
- E-mail: susan.clark@admedsol.com
Estude backup de contato
- Nome: Loïc Limon-Duparcmeur
- Número de telefone: 01606863500
- E-mail: loiclimonduparcmeur@admedsol.com
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Descrição
Inclusion Criteria:
-
Patient is male or female, 18 - 85 years old;
-
Patient is willing and able to give written informed consent;
-
Patient is able to comply with a prior medical examination;
-
Patient is or has been scheduled for a surgical procedure to correct epiphyso-metaphyseal and/or metaphyso-diaphyseal bone void in one of the following anatomical locations either after traumatic injury or elective surgical reconstruction:
- Proximal humerus ▪ Distal radius
- Distal femur ▪ Proximal tibia ▪ Distal tibia
-
Patient is willing and able to comply with the study procedures during surgery and the post-surgical follow up period, up to 12 months.
Exclusion Criteria:
- Patient has had an infection in the same extremity within last 24 months;
- Patient has bone necrosis either after traumatic injury or elective surgical reconstruction at the surgical site;
- Patient has cellulitis;
- Patient has granuloma or non-curetted cyst;
- Patient has a current or previous diagnosis of osteomyelitis;
- Patient has a clinically significant degenerative bone disease;
- Patient has an history of uncontrolled diabetes;
- Patient is alcoholic and/or heavy smoker (> 20 cigarettes per day);
- Patient has a congenital or acquired immunodeficiency;
- Patient has severe bone loss (≥ 40cm3);
- Patient is on long-term steroidal therapy or treatment acting on the calcium or phosphorus metabolism;
- Patient is or has been scheduled for surgery that would involve intra-articular implantation of the study device;
- Patient who has or had an uncontained bone void (cavity) created as a result of trauma injury or surgically created;
- Patient was exposed to any radiation (e.g. X-Rays, handling of radiolabelled materials) other than the normal background radiation within the 12 months before the screening visit;
- Patient is pregnant or breastfeeding;
- Patient who is an employee at the study site;
- Patient is known to be non-compliant with medical treatment or follow-up
- Patient has any significant or unstable medical/psychiatric condition that, in the opinion of the Investigator, would interfere with their ability to participate in the study;
- Patient is currently enrolled or planning to enrol in another clinical study or treatment with another investigational drug/device that may interfere with the assessments, visits or outcomes of this study.
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Tratamento
- Alocação: Randomizado
- Modelo Intervencional: Atribuição Paralela
- Mascaramento: Dobro
Armas e Intervenções
Grupo de Participantes / Braço |
Intervenção / Tratamento |
|---|---|
|
Comparador Ativo: FDBS (GraftR3®)
The CE-marked device FDBS (GraftR3®) is a powder that presents an interconnected network that enables the colonization of bone cells and biological fluid uniformly within the matrix required for the biological exchanges particularly for bone ingrowth. It is intended for the reconstruction of bony voids or bone gaps in orthopaedic applications that are not intrinsic to the stability of the bone structure. It acts as a bone void filler by occupying the defect and supporting bone ingrowth from the surrounding viable tissue. The clinical investigation is designed to generate data on the performance and safety of FDBS in orthopaedic trauma surgery. |
Use of FDBS (GraftR3®) in surgical procedure to correct epiphyso-metaphyseal and/or metaphyso-diaphyseal bone defect in one of the following anatomical locations: Proximal humerus, Distal radius, Distal femur, Proximal tibia, Distal tibia. |
|
Comparador Ativo: IBS (MBCP® Putty)
The CE-marked device IBS (MBCP® Putty) is an injectable bone substitute to fill and reconstruct bone voids or bone gaps of the skeletal system (e.g. extremities, spine and pelvis). It acts as a bone void filler by occupying the defect and supporting bone ingrowth from the surrounding viable tissue. For contextual interpretation, the study will include patients treated with this technology, as published data remain limited for certain indications such as surgically created bone defects (e.g. post cyst removal) or bone gaps due to traumatic injury |
Use of IBS (MBCP® Putty) in surgical procedure to correct epiphyso-metaphyseal and/or metaphyso-diaphyseal bone defect in one of the following anatomical locations: Proximal humerus, Distal radius, Distal femur, Proximal tibia, Distal tibia. |
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Evaluation of performance and safety of FDBS and IBS in the reconstruction of bone voids in the extremities
Prazo: At 12 months post-surgery
|
Achievement of successful bone integration (without occurrence of Major Adverse Events) through radiological evaluation within 12 months by assessing interdigitation in 3 out of 4 anatomical planes (anterior/posterior/lateral/medial) |
At 12 months post-surgery
|
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Evaluation of device-related Adverse Events associated with FDBS and IBS in the reconstruction of bone voids in the extremities
Prazo: Within 12 months post-surgery
|
Incidence of device related Adverse Events |
Within 12 months post-surgery
|
|
Functional evaluation after use of FDBS and IBS in the reconstruction of bone voids in the upper extremities
Prazo: Within 12 months post-surgery
|
Functional mobility restoration by scoring patient's physical disability and symptoms through QuickDASH outcome measure |
Within 12 months post-surgery
|
|
Functional evaluation after use of FDBS and IBS in the reconstruction of bone voids in the lower extremities
Prazo: Within 12 months post-surgery
|
Functional mobility restoration by scoring patient's physical disability and symptoms through LEFS outcome measure |
Within 12 months post-surgery
|
|
Evaluation of subject's pain after use of FDBS and IBS in the reconstruction of bone voids in the extremities
Prazo: Within 12 months post-surgery
|
Patient's pain intensity at trauma/surgical site 0 = no pain; 10 = worst pain imagineable |
Within 12 months post-surgery
|
|
Evaluation of usability of FDBS and IBS in the reconstruction of bone voids in the extremities
Prazo: Within 12 months post-surgery
|
Clinician satisfaction with use of FDBS and IBS as per IFU |
Within 12 months post-surgery
|
|
Evaluation of the difference in performance of FDBS versus IBS in the reconstruction of bone defects in the extremities
Prazo: At 12 months post-surgery
|
Difference between FDBS and IBS in successful rates of bone integration through radiological evaluation at 12 months |
At 12 months post-surgery
|
Colaboradores e Investigadores
Patrocinador
Colaboradores
Investigadores
- Investigador principal: Peter Giannoudis, Leeds General Infirmary, Great George Street Leeds LS1 3EX, United Kingdom
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Estimado)
Conclusão Primária (Estimado)
Conclusão do estudo (Estimado)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
- STD-030-001
Plano para dados de participantes individuais (IPD)
Planeja compartilhar dados de participantes individuais (IPD)?
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .