Background:
Adenoma detection rate is one of the most quality indicator: an accumulating body of evidence has shown that detection and resection of pre-cancerous adenoma by colonoscopy could effectively prevent colorectal cancer (CRC) and its related mortality1,2. Among various colonoscopy quality indicators, such as cecal intubation rate, withdrawal time, and adenoma detection rate (ADR), ADR is the most important one and most closely associated with the subsequent risk of CRC3,4. A recent study further demonstrated the improvement of ADR could reduce subsequent risk of CRC5.
Equipment and technique to improve ADR: To be noted, among all colorectal neoplasm, non-polypoid lesions, such as flat or depressed lesions, carries higher likelihood to be overlooked during conventional colonoscopy and these overlooked lesions were the main etiology of post-colonoscopy colorectal cancer (PCCRC)6. Nowadays, several colonoscopy technologies had been developed to enhance the detection of colorectal adenoma such as using digital or dye-spray chromoendoscopy7 or add-on device such as Cap/Endocuff/third eye/FUSE-assisted endoscopy8. Among them, some had showed the potential to enhance the detection of non-polypoid lesion, for example, the next-generation NBI9 or iSCAN10.
Application of 3D endoscopy on GI disease: 3D endoscopy is a new technology that using image processing technique to offer more information on tissue depth in comparison with conventional 2D endoscopy. The utility of 3D endoscopy on GI tract was mainly from upper GI tract and it was proved to enhance the diagnostic accuracy on superficial gastric tumors11 and shortened the procedure time during performing gastric endoscopic submucosal dissection (ESD)12. However, few is known that whether 3D colonoscopy could enhance the ADR, especially for non-polypoid lesion detection, during colonoscopy examination.
Positive fecal immunochemical test(FIT) group Among subjects who receive colonoscopy examination, higher advanced adenoma or invasive caners were found in FIT positive group. However, still about half of positive FIT subjects who received colonoscopy exam, have negative colonoscopy result. Non polypoid lesions could be overlooked during the colonoscopy. Therefore, we tried to use this prospective, multicenter, randomized control study to demonstrate the efficacy of 3D colonoscopy on adenoma detection in comparison with conventional 2D colonoscopy in this kind of high risk group.
Aperçu de l'étude
Statut
Intervention / Traitement
Type d'étude
Inscription (Estimé)
Phase
- N'est pas applicable
Contacts et emplacements
Coordonnées de l'étude
- Nom: Hsuan-Ho Lin, MD
- Numéro de téléphone: 886-9-72-654-359
- E-mail: tostart21@gmail.com
Lieux d'étude
-
-
-
Hsinchu, Taïwan
- Recrutement
- National Taiwan University Hospital, Hsinchu Branch
-
Contact:
- Hsuan-Ho Lin
- Numéro de téléphone: 886-9-72-654-359
- E-mail: tostart21@gmail.com
-
Chercheur principal:
- Hsuan-Ho Lin, MD
-
Taipei, Taïwan
- Recrutement
- National Taiwan University Hospital
-
Contact:
- Li-Chun Chang, MD. PhD.
- Numéro de téléphone: 886-9-72-651-258
- E-mail: lichunchang@ntu.edu.tw
-
Taipei, Taïwan
- Recrutement
- National Taiwan University Cancer Center
-
Contact:
- Hao-Che Chang, MD
- Numéro de téléphone: 886-2-23123456
- E-mail: andrewhcchang@gmail.com
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
La description
Inclusion Criteria:
- Subjects who are 40 years of older
- Subjects who have positive fecal immunochemical test
Exclusion Criteria:
- Contraindication for colonoscopy
- Subjects with familiar or hereditary polyposis
- Subjects with history of colectomy
- Inadequate bowel cleansing level
- Subjects with inflammatory bowel disease
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Diagnostique
- Répartition: Randomisé
- Modèle interventionnel: Affectation parallèle
- Masquage: Double
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
|---|---|
|
Expérimental: 3D colonoscopy
Use 3D machine to generate the 3D image |
Use 3D machine to generate the 3D image |
|
Aucune intervention: 2D colonoscopy
Traditional colonoscopy |
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Délai |
|---|---|
|
Taux de détection des adénomes
Délai: 30 minutes
|
30 minutes
|
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Taux de détection des polypes
Délai: 30 minutes
|
30 minutes
|
|
|
nombre d'adénomes par coloscopie,
Délai: 30 minutes
|
30 minutes
|
|
|
nombre de polypes par coloscopie,
Délai: 30 minutes
|
30 minutes
|
|
|
Flat-ADR
Délai: 30 minutes
|
detection rate of flat adenoma |
30 minutes
|
|
Proximal ADR
Délai: 30 minutes
|
detection rate of adenoma at proximal colon |
30 minutes
|
|
SSLDR
Délai: 30 minutes
|
detection rate of sessile serrated lesion |
30 minutes
|
|
AADR
Délai: 30 minutes
|
detection rate of advanced adenoma |
30 minutes
|
Collaborateurs et enquêteurs
Parrainer
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Réel)
Achèvement primaire (Estimé)
Achèvement de l'étude (Estimé)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Autres numéros d'identification d'étude
- 202311028DIPA
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
produit fabriqué et exporté des États-Unis.
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .