Background:
Adenoma detection rate is one of the most quality indicator: an accumulating body of evidence has shown that detection and resection of pre-cancerous adenoma by colonoscopy could effectively prevent colorectal cancer (CRC) and its related mortality1,2. Among various colonoscopy quality indicators, such as cecal intubation rate, withdrawal time, and adenoma detection rate (ADR), ADR is the most important one and most closely associated with the subsequent risk of CRC3,4. A recent study further demonstrated the improvement of ADR could reduce subsequent risk of CRC5.
Equipment and technique to improve ADR: To be noted, among all colorectal neoplasm, non-polypoid lesions, such as flat or depressed lesions, carries higher likelihood to be overlooked during conventional colonoscopy and these overlooked lesions were the main etiology of post-colonoscopy colorectal cancer (PCCRC)6. Nowadays, several colonoscopy technologies had been developed to enhance the detection of colorectal adenoma such as using digital or dye-spray chromoendoscopy7 or add-on device such as Cap/Endocuff/third eye/FUSE-assisted endoscopy8. Among them, some had showed the potential to enhance the detection of non-polypoid lesion, for example, the next-generation NBI9 or iSCAN10.
Application of 3D endoscopy on GI disease: 3D endoscopy is a new technology that using image processing technique to offer more information on tissue depth in comparison with conventional 2D endoscopy. The utility of 3D endoscopy on GI tract was mainly from upper GI tract and it was proved to enhance the diagnostic accuracy on superficial gastric tumors11 and shortened the procedure time during performing gastric endoscopic submucosal dissection (ESD)12. However, few is known that whether 3D colonoscopy could enhance the ADR, especially for non-polypoid lesion detection, during colonoscopy examination.
Positive fecal immunochemical test(FIT) group Among subjects who receive colonoscopy examination, higher advanced adenoma or invasive caners were found in FIT positive group. However, still about half of positive FIT subjects who received colonoscopy exam, have negative colonoscopy result. Non polypoid lesions could be overlooked during the colonoscopy. Therefore, we tried to use this prospective, multicenter, randomized control study to demonstrate the efficacy of 3D colonoscopy on adenoma detection in comparison with conventional 2D colonoscopy in this kind of high risk group.
Panoramica dello studio
Stato
Intervento / Trattamento
Tipo di studio
Iscrizione (Stimato)
Fase
- Non applicabile
Contatti e Sedi
Contatto studio
- Nome: Hsuan-Ho Lin, MD
- Numero di telefono: 886-9-72-654-359
- Email: tostart21@gmail.com
Luoghi di studio
-
-
-
Hsinchu, Taiwan
- Reclutamento
- National Taiwan University Hospital, Hsinchu Branch
-
Contatto:
- Hsuan-Ho Lin
- Numero di telefono: 886-9-72-654-359
- Email: tostart21@gmail.com
-
Investigatore principale:
- Hsuan-Ho Lin, MD
-
Taipei, Taiwan
- Reclutamento
- National Taiwan University Hospital
-
Contatto:
- Li-Chun Chang, MD. PhD.
- Numero di telefono: 886-9-72-651-258
- Email: lichunchang@ntu.edu.tw
-
Taipei, Taiwan
- Reclutamento
- National Taiwan University Cancer Center
-
Contatto:
- Hao-Che Chang, MD
- Numero di telefono: 886-2-23123456
- Email: andrewhcchang@gmail.com
-
-
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Descrizione
Inclusion Criteria:
- Subjects who are 40 years of older
- Subjects who have positive fecal immunochemical test
Exclusion Criteria:
- Contraindication for colonoscopy
- Subjects with familiar or hereditary polyposis
- Subjects with history of colectomy
- Inadequate bowel cleansing level
- Subjects with inflammatory bowel disease
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Diagnostico
- Assegnazione: Randomizzato
- Modello interventistico: Assegnazione parallela
- Mascheramento: Doppio
Armi e interventi
Gruppo di partecipanti / Arm |
Intervento / Trattamento |
|---|---|
|
Sperimentale: 3D colonoscopy
Use 3D machine to generate the 3D image |
Use 3D machine to generate the 3D image |
|
Nessun intervento: 2D colonoscopy
Traditional colonoscopy |
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Lasso di tempo |
|---|---|
|
Tasso di rilevamento dell'adenoma
Lasso di tempo: 30 minuti
|
30 minuti
|
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Tasso di rilevamento dei polipi
Lasso di tempo: 30 minuti
|
30 minuti
|
|
|
numero di adenomi per colonscopia,
Lasso di tempo: 30 minuti
|
30 minuti
|
|
|
numero di polipi per colonscopia,
Lasso di tempo: 30 minuti
|
30 minuti
|
|
|
Flat-ADR
Lasso di tempo: 30 minutes
|
detection rate of flat adenoma |
30 minutes
|
|
Proximal ADR
Lasso di tempo: 30 minutes
|
detection rate of adenoma at proximal colon |
30 minutes
|
|
SSLDR
Lasso di tempo: 30 minutes
|
detection rate of sessile serrated lesion |
30 minutes
|
|
AADR
Lasso di tempo: 30 minutes
|
detection rate of advanced adenoma |
30 minutes
|
Collaboratori e investigatori
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Completamento primario (Stimato)
Completamento dello studio (Stimato)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Altri numeri di identificazione dello studio
- 202311028DIPA
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
prodotto fabbricato ed esportato dagli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .